Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06CM05677
Permit Details
Apply Date:
10/31/2006
Applicant:
N/A
Description:
NEW CAR DEALERSHIP W/PARKING LOT
Architects:
- ARCHITECTURAL DESIGN GROUP INC
Contractors:
- CANYON BUILDING AND DESIGN L L C
Permit Reviews
Permit Number - T06CM05677
Permit Status: C of o
Permit Description: NEW CAR DEALERSHIP W/PARKING LOT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/28/2008 | REVISION - SITE | 03/03/2008 | COMPLETED |
02/27/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 03/03/2008 | COMPLETED |
02/27/2009 | REVISION - SITE | 03/02/2009 | COMPLETED |
03/20/2008 | REVISION - SITE | 04/01/2008 | COMPLETED |
04/15/2008 | REVISION - SITE | 04/16/2008 | COMPLETED |
04/22/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 04/28/2008 | COMPLETED |
05/02/2007 | RESUBMITTAL - SITE ALL | 06/15/2007 | COMPLETED |
06/05/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 06/07/2007 | COMPLETED |
06/07/2007 | 3RD PARTY REVIEW-COMMERCIAL | 08/10/2007 | COMPLETED |
06/25/2007 | RESUBMITTAL - SITE ALL | 08/01/2007 | COMPLETED |
08/01/2007 | RESUBMITTAL - SITE ALL | 08/16/2007 | COMPLETED |
08/10/2007 | POST 3RD PARTY REVIEW | 08/14/2007 | COMPLETED |
08/14/2007 | RESUBMITTAL | 08/16/2007 | COMPLETED |
10/31/2006 | PLANS OK TO SUBMIT - SITE | 11/01/2006 | COMPLETED |
11/01/2006 | SITE | 12/14/2006 | COMPLETED |
11/01/2007 | POST 3RD PARTY REVIEW | 11/26/2007 | COMPLETED |
11/26/2007 | REVISION - - 2ND | 11/26/2007 | COMPLETED |
11/28/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 11/29/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05677
Permit Status: C of o
Permit Description: NEW CAR DEALERSHIP W/PARKING LOT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/31/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM05677
Permit Description: NEW CAR DEALERSHIP W/PARKING LOT
Total Completed Inspections - 44
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/13/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
10/31/2007 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* CMU REINFORCEMENT @ GRID 7/C TO 1 & B/9.4 TO 11 9.9/B TO A.7 - A.7/9.4 TO 11 - A.4/9.4 TO 11 - 11/A TO A.7 & 9.4/A TO A.7 TO 12' AFF AND 20 METAL BUILDING COLUMN POST BASES |
11/02/2007 | ELECTRIC - CONSTRUCTION POWER | RJIROUDE | Approved | IVRS - Inspection :* OK CENTER ROW POLE LIGHTS UNDERGROUND SOUTH PARKING LOT |
11/14/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* WEST BLDG - CAR WASH TOP OUT |
11/14/2007 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | IVRS - Inspection :* |
11/21/2007 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* SITE SEWER PRE-CON ATTENDED BY BOBBY CANYON BLD DAVID, ROBERT EAGLE ROCK INSTALLATION TO MEET 2006 UPC REQUIREMENTS WITH REVISED CITY APPROVED PLANS IF INSTALLATION DIFFERS FROM APPROVED PLAN |
12/04/2007 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* CONTRACTOR CANCELLED |
12/14/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* OK 9 POLE BASES SOUTH 1/2 OF LOT |
12/14/2007 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
12/18/2007 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* CAR WASH BLDG @ GRID A TO B/9.3 TO 11 |
12/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* 9 LIGHT POLE BASES @ SOUTH END OF SITE (TWO ROWS OF 4 EACH) AND 1 @ EAST SIDE ACROSS FROM SERVICE BAYS |
12/18/2007 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* VENT FROM INTERCEPTOR BACK TO 3' AFF AT BLD OK |
12/21/2007 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* 1) WATER TEST ON TRENCH DRAIN AT CAR WASH OK |
01/22/2008 | ELECTRIC - UFER | GDABBS | Approved | |
04/01/2008 | MECHANICAL - UNDERGROUND | JMILITEL | Approved | IVRS - Inspection :* |
04/02/2008 | TEP CLEARANCE - AM | BFLORES | Approved | TEC PER R.JIROUDEK |
04/15/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
04/15/2008 | OUTDOOR LIGHTING FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
05/21/2008 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* MEZZINE DECK @ GRID LINES B.8 TO G/7.1 TO 5 |
07/03/2008 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* EXTERIOR SHEATHING @ SERVICE LANES ROOF LINE |
09/03/2008 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* METAL ROOF DECKING MATERIAL & WELDS @ GRID LINES B.5 TO G.9/1.0 TO 5.0 - SPECIAL INSPECTION APPROVED |
09/29/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* AT SHOWROOM INTERIOR SOFFITS, CEILING LIDS, AND PONY WALLS OK |
10/08/2008 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* RESTROOMS AND SHOWROOM AREA ONLY |
10/08/2008 | PLUMBING - ROOF DRAINS | RRICH | Approved | IVRS - Inspection :* |
10/16/2008 | ENGINEERING - FINAL | NKALAHAR | Approved | 2 SITE VISITS -CHANGING PUBLIC ACCESS CONSTRUCTION AREA IS FENCED AND PUBLIC TRAFFIC IS ISOLATED |
10/27/2008 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* NORTH CORRIDOR & OFFICES -- OK TO SET TILES |
10/30/2008 | PLUMBING - ABOVE CEILING | RRICH | Approved | |
10/31/2008 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* MAIN ENTRY ARCHWAY |
10/31/2008 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* ALL CLOSET FLANGES OK |
11/04/2008 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR REMAINING CEILING TILES |
11/06/2008 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | IVRS - Inspection :* |
11/14/2008 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
11/14/2008 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | IVRS - Inspection :* 12 PSI TEST IS OK LEFT GAS CARD |
11/17/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
11/17/2008 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* |
11/19/2008 | FIRE - FINAL | LTHOMAS | Approved | |
11/21/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* TALKED TO TRADE INSPECTORS -- OK TO APPLY FOR TCO |
11/21/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* ROOF INSPECTION 1. TIGHTEN LOOSE FITTINGS 2. INSTALL BONDING BUSHINGS AROUND CONCENTRICS SALES BUILDING 1. OUTDOOR EM LIGHTS NOT WORKING 2. SOME INDOOR EM LIGHTS NOT WORKING 3. WILL NEED TO CHECK ALL OUTDOOR LIGHTING WHEN COMPLETE |
11/21/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* 1. NEED PARTITIONS IN RESTROOMS #141, 144 2. NEED COMPLETION OF SINKS IN ROOMS #145, 150 3. COMPLETE INSULATION AT WATER HEATER PIPING ROOM #139 4. COMPLETE HANDICAP URINAL INSTALL IN RESTROOM #144 RECEIVED BACTERIA REPORT FOR POTABLE WATER IN SHOWROOM AREA |
11/21/2008 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
12/02/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* OK PONY WALLS @ 2 FRONT OFFICES IN SHOWROOM AREA |
03/05/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
03/16/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
06/08/2010 | RIGHT OF WAY - FINAL | BGRANT | Approved |