Permit: T06CM05677

Parcel: 130140230


Addresses:

4220 E 22ND ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05677

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/17/2009 FRAMING Approved
09/29/2008 FRAMING Partial Approval IVRS - Inspection :*
AT SHOWROOM INTERIOR SOFFITS, CEILING LIDS,
AND PONY WALLS OK
09/17/2008 FRAMING Partial Approval IVRS - Inspection :*
ROOMS #129, 130, 131, 132, 133, 134, 138, 139, 140, 141, 144, 143, 145, 146, 147, 148, 118, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128 AND EXTERIOR SOFFITS DOWN TO WINDOW WALLS AT SHOWROOM #101 -- SPECIAL INSPECTOR HAS INSPECTED WELDS
09/03/2008 FRAMING Partial Approval IVRS - Inspection :*
METAL STUD FRAMING AT NEW SHOWROOM PARAPET
WALLS @ GRID LINES 5.0/5.5 TO 7.0 & 1.0/B.5 TO B.9
SPECIAL INSPECTION OF CLIPS/WELDS APPROVED
08/27/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
07/03/2008 FRAMING Partial Approval IVRS - Inspection :*
METAL STUD FRAMING AT SERVICE LANES LID
06/27/2008 FRAMING Partial Approval IVRS - Inspection :*
AT ROOMS #149, 160, 158, 159, 161, 162 AND 184
06/25/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
06/25/2008 FRAMING Partial Approval IVRS - Inspection :*
171, 172, 173 & 174
06/18/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
06/16/2008 FRAMING Partial Approval IVRS - Inspection :*
ROOMS #135, 136, 137, 159, 161, 162, 164 AND SHEAR WALL @ F.4/D
06/06/2008 FRAMING Partial Approval IVRS - Inspection :*
EXTERIOR METAL STUD FRAMING @ 5.2/I TO K, K/5.2 TO 7.1,
7.1/I TO K AND C.5 TO G.1/5
06/02/2008 FRAMING Partial Approval IVRS - Inspection :*
PARTIAL APPROVAL @ GRID LINES 5 TO 8/A TO L
05/27/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
05/21/2008 FRAMING Partial Approval IVRS - Inspection :*
1ST FLOOR ONLY @ GRID LINES
B.8 TO G/7.1 TO 5
05/13/2008 FRAMING Partial Approval IVRS - Inspection :*
LEDGERS @ GRID LINES 5 & 5.6/C TO F.5 AND 1ST FLOOR FRAMING @ GRID LINES C TO F.5/6.5, 5.6 & 5 OK
05/09/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
05/09/2008 FRAMING Partial Approval IVRS - Inspection :*
LEDGER, PERLINS AND TRUSSES AT GRID LINE 7 TO 6.5/B.7 TO G.1 AND LEDGER AND PERLINS @ B.7/5 TO 7 @ SECOND FLOOR MEZZANINE DECK
03/11/2008 FRAMING Partial Approval IVRS - Inspection :*
SHEETROCK NAILING @ ELEC., MECH., AND FIRE ONLY
03/03/2008 FRAMING Partial Approval IVRS - Inspection :*
MECH/ELECT. ROOM ONLY