Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM05677
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/17/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | ||
01/12/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 17 (TOTAL) LIGHT POLE BASES REINFORCEMENT STEEL @ CORNER NORTHEAST DISPLAY LOT |
|
11/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1 LIGHT POLE BASE ON EAST SIDE BY DRIVE |
|
11/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 LIGHT POLE BASES @ N/E OF NEW BUILDING |
|
08/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3 LIGHT POLE BASES ON EAST SIDE NEXT TO SERVICE DRIVETHRU |
|
08/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FIVE LIGHT POLE BASE RUNNING NORTH TO SOUTH ALONG WEST SITE WALL -- OK TO POUR |
|
08/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 7 ADDITIONAL LIGHT POLE BASES CAISSONS @ NORTHWEST NEW CAR DISPLAY LOT |
|
08/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 ADDITIONAL LIGHT POLE BASES AS NOTED ON SHEET C1.1 IN N/W PARKING AREAS NOTE: DO NOT POUR N/W & N/E CORNER POLE BASES IN N/W NEW CAR DISPLAY LOT - FULL OF MUD & WATER |
|
08/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 8 LIGHT POLE CAISSONS AS INITIALED ON TO BE APPROVED REVISED PLANS - 36" GALVANIZED 3/4 BOLTS 4" HOOK USED 1. PROVIDE DOCUMENTATION FOR MANUFACTURE BOLT SIZE REG. |
|
07/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TWO ISOLATED COLUMN FOOTINGS #F-5 @ LINE 3/E.3 AND SITE WALL FOOTING RUNS N/S WEST AT SHOWROOM AND EAST TO WEST FROM SERVICE BAYS |
|
06/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. C.5 TO (3) F10 FOOTING C.5 AT 1, 1.5, 3 F3 & F4 FOOTING 2. F10 FOOTING 3 TO 5 G.1 TO I F3 FOOTING AT G.1 - 3 3. (2) F7 FOOTING F-4 FOOTING LINE 1 D.9 E.6 6.1 |
|
05/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* APPROX. 250 LF BALANCE OF WEST SIDE SITE RETAINING WALL FOOTING EXCEPT NORTH END CAP |
|
05/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
05/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 150 L.F OF RETAINING WALL FOOTING @ WEST SIDE |
|
04/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
04/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* AFTER HRS. INSP. $150.00 PAID BY MONEY ORDER #08-814507497 MONO FOOTING AT GRID LINE B.5 TO I/5 TO 7 -- OK TO POUR |
|
04/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
02/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL @ GRID G9.7/7.1 - JAM FOOTING |
|
01/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* (3) #F6 COLUMN FOOTINGS @ K/5.2, 6 & 7 AND DUMPSTER ENCLOSURE FOOTING @ S/W CORNER |
|
01/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F-10 & F-9 BUILDING FOOT @ RMS #178, 183 AND 186 INTERIOR CMU FOOTING @ GRID LINES D.3/7 TO 6.5 AND 6.5/C TO F AND COLUMN FOOTINGS @ 5/C.9 AND E.3 6/C.9 & E.3 AND G.1/6.7 & 6.5 |
|
01/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTINGS & COLUMN FOOTINGS @ GRID LINES G.1/5 TO 5.5 5/E.6 TO F.3 - 5/1 TO 1.5 - B.7/5 TO7 - B/6.5 TO 7 7/G.9 TO G.9.5 - 7/G.9.9 TO I - I/7, 6.5, 6.2, 5.8, 5.2 TO 4 OK |
|
01/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PERIMETER FOOTINGS @ SHOWROOM @ GRID LINES G.1/1 TO 1.8 - 1.1/F TO F.5 - 1.1/C.5 TO C.9 AND C.5/1.1 TO 5 |
|
12/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 9 LIGHT POLE BASES @ SOUTH END OF SITE (TWO ROWS OF 4 EACH) AND 1 @ EAST SIDE ACROSS FROM SERVICE BAYS |
|
12/14/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* NO APPROVED PLANS |
|
10/29/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
10/02/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* REINFORCEMENT STEEL @ FOOTINGS @ GRID LINES 9.3/A TO B - B/9.3 TO 11 - 11/A TO B & A/11 TO 9.3 |
|
09/28/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. PERIMETER WALL FOOTINGS @ GRID LINES 7/B TO G.9 B/7 TO NORTH OF COLUMN @ B/8 - H/7 TO 11 2. COLUMN FOOTINGS @ H/8 - B/7 - 7/B.7 - 7/C.9 - 7/D.9 7/E7.5, 7/G1 & 7/G9 2. COLUMN FOOTINGS @ H/8 - B/7 |
|
09/26/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. 5 - F1 COLUMN FOOTING @ 7/C - 7/D - 7/E - 7/F - 7/G 2. SITE WALL FOOTING ON SOUTH & WEST AS PER C1.2/AZ DETAIL |
|
09/25/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* NO SUPERINTENDENT ON SITE NO PERMIT CARD ON SITE |
|
09/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED BY PHONE |