Permit: T06CM05677

Parcel: 130140230


Addresses:

4220 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06CM05677

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/12/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
03/11/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
PROVIDE A UPC APPROVED AIR GAP FITTING BETWEEN POTABLE WATER AND DRAIN CONNECTION FROM RO MACHINE;
BOTH LOCATIONS
11/21/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. NEED PARTITIONS IN RESTROOMS #141, 144
2. NEED COMPLETION OF SINKS IN ROOMS #145, 150
3. COMPLETE INSULATION AT WATER HEATER PIPING
ROOM #139
4. COMPLETE HANDICAP URINAL INSTALL IN RESTROOM #144

RECEIVED BACTERIA REPORT FOR POTABLE WATER IN SHOWROOM AREA
11/20/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SEAL ALL OPEN DRAINS AND VENTS ON INTERIOR OF BLD.
2. COMPLETE FIXTURES AND MAKE FUNCTIONAL
3. COMPLETE INSULATION ON HOT WATER PIPING
4. COMPLETE CLEANOUTS AND BACKWATER VALVE ACCESS ON EXTERIOR
5. CALL IN 03057 & 03052 INSPECTIONS WITH 03090
10/08/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
RECEIVED BACTERIA REPORT FOR POTABLE WATER SYSTEM
LINE 5 SOUTH OK EXCEPT ROOMS 150 AND CORRIDOR EWF
04/16/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
THIS INSPECTION FOR ONLY SERVICE BAY & CARWASH AREA
RECEIVED (5) IN HOUSE BACKFLOW CERTIFICATIONS
04/15/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SERVICE BAY NOTES:
1. SEE NOTE FROM 4/8/08 INSPECTION
2. MAKE FLOOR DRAIN FLUSH TO AVOID TRIPPING HAZARD
3. PROVIDE BACKFLOW CERTIFICATIONS FOR ALL IN HOUSE DEVICES
4. REDLINE ALL CHANGES ON APPROVED PLANS FOR FUTURE CITY APPROVED REVISION
5. PROVIDE INSULATION ON WATER PIPING SUBJECT TO FREEZING
6. PROVIDE THREAD SEALANT ON CLEANOUT PLUGS
7. PREVIOUS TRAFFIC RATED CLEANOUTS IN FLOOR OF TRAFFIC AREAS.