Permit: T07CM00308
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
3235 N FLOWING WELLS RD
Address NEW:
3235 N FLOWING WELLS RD
Apply Date:
01/25/2007
Applicant:
N/A
Description:
TI: RESTAURANT- TACOS & SNOW CONES
Architects:
- DOMINGUEZ, PORFIRIO
Contractors:
- ARIZONA RESTAURANT SUPPLY INC
- ARIZONA STYLE CONSTRUCTION
- SUPER DRAIN ROOTER AND PLUMBERS INC *C
Permit Reviews
Permit Number - T07CM00308
Permit Status: C of o
Permit Description: TI: RESTAURANT- TACOS & SNOW CONES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/25/2007 | PLANS OK TO SUBMIT - COMM | 01/26/2007 | COMPLETED |
| 01/25/2007 | PLANS OK TO SUBMIT - SITE | 01/26/2007 | COMPLETED |
| 01/26/2007 | COMMERCIAL TI | 03/12/2007 | COMPLETED |
| 01/26/2007 | SITE | 03/12/2007 | COMPLETED |
| 04/09/2007 | RESUBMITTAL | 06/20/2007 | COMPLETED |
| 04/09/2007 | RESUBMITTAL - SITE ALL | 05/07/2007 | COMPLETED |
| 05/07/2007 | RESUBMITTAL | 07/18/2007 | COMPLETED |
| 06/20/2007 | RESUBMITTAL - SITE ALL | 07/18/2007 | COMPLETED |
| 07/20/2007 | COMMERCIAL TI | 07/25/2007 | COMPLETED |
| 07/20/2007 | RESUBMITTAL - SITE ALL | 07/27/2007 | COMPLETED |
| 07/25/2007 | RESUBMITTAL | 07/27/2007 | COMPLETED |
| 07/27/2007 | RESUBMITTAL | 08/08/2007 | COMPLETED |
| 10/05/2007 | REVISION - SITE | 10/08/2007 | COMPLETED |
| 11/14/2007 | REVISION - - 1ST | 11/14/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM00308
Permit Status: C of o
Permit Description: TI: RESTAURANT- TACOS & SNOW CONES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/25/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM00308
Permit Description: TI: RESTAURANT- TACOS & SNOW CONES
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2007 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 09/19/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 09/19/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 09/25/2007 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* - OK DINING AREA ONLY - KITCHEN AREA NEEDS CABLING & BOXES TO BE COVERED AND SUPPORTED TO CODE. INSTALL SEISMIC WIRES ON GRID FIXTURES. |
| 09/25/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 09/27/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/03/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/04/2007 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/05/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | CONDENSATE CANNOT TERMINATE ONTO THE SIDEWALK PROVIDE A VENT FOR WATER HEATER OK FOR CEILING TILES CHECKED WELDS ON GREASE DUCT. OK TO FIRE WRAP. FIRE WRAP ON TOP OF HOOD MUST BE SECURED. PROVIDE INSTALL INSTRUCTIONS. |
| 10/17/2007 | MECHANICAL - HOODS | MRAMBER | Approved | IVRS - Inspection :* GREASE DUCT WRAP OK OK TO PROCEED WITH SUPPRESSION SYSTEM |
| 10/26/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
| 10/26/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 11/06/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* FLANGES OK PIPE INSULATION AT WH OK WH HAS HEAT TRAP NIPPS |
| 11/19/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 12/06/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* INCREASE M.U.A TO WITHIN 10% OF DESIGN PROVIDE GREASE TROUGH AT HOOD PROVIDE SPACING ON CONDENSATE PIPING PROVIDE BLOCKING ON ELEC. BOX PROVIDE GREASE TROUGH ON ROOF PROVIDE REQUIRED A/C EQUIPMENT ON ROOF |
| 12/06/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. REVISE PANEL DIRECTORIES SO THEY ARE CORRECT, LEGIBLE AND NEAT, SPELLED CORRECTLY - NO SCRIBBLE 2. SERVICE DISCONNECT TO BE UNLOCKED 3. ALARM WIRING IN PROGRESS 4. MULTI-WIRE BRANCH CKTS TO TERMINATE ON SEPARATE PHASES 5. PROVIDE DISCONNECTING MEANS FOR ICE MACHINE 6. FLEX NOT ALLOWED FOR DISPLAY CASES - IT IS SUBJECT TO PHYSICAL DAMAGE, BOXES AND RECEPTACLES NOT TO BE MOUNTED TO MOVABLE DISPLAY CASES ON ROOFTOP - AC 1 KINKED CONDUIT, LOOSE FITTINGS, NO STRAP, UNDERSIZED GROUND, DISCONNECT NOT TO BLOCK ACCESSIBLE COVER, PINCHED OPEN WIRING, MISSING K.O CONTACTOR J-BOX NOT SEALED/SECURE SELF TAP SCREW NOT ALLOWED FOR GROUND, STRAP ALL FLEX. |
| 12/11/2007 | ENGINEERING - FINAL | MRUSSO | Approved | 1) PROVIDE "ONEWAY " SIGNAGE" AS SHOWN ON PLAN, NOTE #29. 2) PROVIDE 6" WATER HARVESTING AREA WITH DRAINAGE TO WALL OPENING, NOTE #32. 3) COMPLETE LANDSCAPE WORK. 4) INSTALL WHEEL STOPS AS SHOWN ON PLAN - ADD PARKING SPACE TO NORTH SIDE OF BLDG. 5) PROVIDE TWO - CLASS II BICYCLE PARKING SPACES. 6) PROVIDE HC SIGN FOR PARKING SPACE. 7) INSTALL WEEP HOLES IN SCREEN WALL TO ALLOW FOR DRAINAGE, NOTE #38. 8) PROVIDE APPROVAL FROM ARCHETECT FOR CHANGES MADE TO THE 6' SCREEN WALL TO A 2' SCREEN WALL SEE NTE #28. |
| 12/21/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 12/21/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 01/22/2008 | HEALTH DEPT - FINAL 724-7908 | RBROWNIN | Approved | |
| 01/25/2008 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 01/25/2008 | FIRE - FINAL | LLAKEY | Approved | |
| 01/28/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 02/29/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 03/04/2008 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/01/2008 | PERMIT FINALED | LJACKSON | Approved | |
| 04/01/2008 | BUILDING - FINAL | AQUIROZ | Approved |