Permit: T06CM00288
Permit Details
Apply Date:
01/17/2006
Applicant:
N/A
Description:
NEW WAREHOUSING OF BROADCASTING EQUIPMENT:ANTENNA SYSTEM
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T06CM00288
Permit Status: C of o
Permit Description: NEW WAREHOUSING OF BROADCASTING EQUIPMENT:ANTENNA SYSTEM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/17/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 01/17/2006 | COMPLETED |
| 01/17/2006 | 3RD PARTY REVIEW-COMMERCIAL | 09/22/2006 | COMPLETED |
| 02/20/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 03/23/2007 | COMPLETED |
| 03/23/2007 | OTHER | 03/23/2007 | COMPLETED |
| 03/23/2007 | REVISION - - 1ST | 04/13/2007 | COMPLETED |
| 04/04/2007 | REVISION - - 2ND | 04/10/2007 | COMPLETED |
| 04/13/2007 | REVISION - - 2ND | 04/13/2007 | COMPLETED |
| 07/05/2006 | POST 3RD PARTY REVIEW | 10/10/2006 | COMPLETED |
| 07/12/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 07/12/2007 | COMPLETED |
| 10/03/2006 | POST 3RD PARTY REVIEW | 10/20/2006 | COMPLETED |
| 10/16/2006 | OTHER | 10/19/2006 | COMPLETED |
| 10/19/2006 | OTHER | 11/16/2006 | COMPLETED |
| 11/09/2006 | SITE | 11/16/2006 | COMPLETED |
| 11/13/2006 | RESUBMITTAL | 11/16/2006 | COMPLETED |
| 11/16/2006 | OTHER | 11/21/2006 | COMPLETED |
| 12/05/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 12/08/2006 | COMPLETED |
| 12/18/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 12/19/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00288
Permit Status: C of o
Permit Description: NEW WAREHOUSING OF BROADCASTING EQUIPMENT:ANTENNA SYSTEM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/17/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM00288
Permit Description: NEW WAREHOUSING OF BROADCASTING EQUIPMENT:ANTENNA SYSTEM
Total Completed Inspections - 45
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2006 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* OK 4/0 BONDED TO REBAR |
| 12/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* OBSERVATION INSPECTION - PARTIAL APPROVAL OK TO POUR MAIN BUILDING PERIMETER AND COLUMN FOOTINGS AS PER NOTE BELOW -- AWAITING NEW APPROVED PLANS WHICH MUST MATCH OBSERVATION NOTES. NOTE #1: 1. PERIMETER FOOTING F-6 - 2 #5'S CONTINUOUS W/1 #4 @ 24" O.C AND #5 VERTICALS @ 48" O.C 2. PERIMETER & INTERIOR BEARING F- 5 FOOTINGS - 2- #5 CONTINUOUS T & B W/1 #4 @ 24" O.C 3. F-1 COLUMN FOOTINGS - 4 - #4'S EACH WAY - 2'6"X2'6" (8 EACH) 4. F-2 COLUMN FOOTINGS - 5 - #4'S EACH WAY 3'6" X 3'6" (7 EACH) 5. F-3 COLUMN FOOTINGS - 4 - #4'S EACH WAY 3'0" X 3'0" (5 EACH) 6. F-4 COLUMN FOOTINGS - 4- #5'S EACH WAY 4'6" X 4'6" (5 EACH NOTE #2: REINFORCING STEEL IN ABOVE FOOTINGS MUST MATCH THE SCHEDULE ON THE NEW PLANS WHEN THEY ARE APPROVED BY THE CITY. ABOVE INSPECTION CONDUCTED PER JESSE SANDERS - PROCEED AT OWN RISK |
| 12/11/2006 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* STEM/RETAINING WALL AT MAIN BUILDING PAD OK TO GROUT |
| 12/20/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* WATER TEST FROM EXTERIOR 2-WAY CLEANOUT INCLUDING 4" PER INITIAL TO FLOOR SINK BACK UPSTREAM FOR RESTROOMS 1. SHALL PROVIDE FULL SIZE UPPER TERMINAL CLEANOUT AT BOTH STOOLS FOR OVER 5' DISTANCE FROM MAIN BUILDING DRAIN. NOTE: REDLINES TO BE ON SITE FOR FUTURE INSPECTIONS AND SHADING OF PIPING IS REQUIRED. |
| 12/21/2006 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection :* 1. FEEDER SW BOARDS A & B TO UTILITIES TRANS OK 2. FEEDER SW BOARDS A & B TO GENERATORS & ATS OK 3. FEEDER SW BOARDS TO MECH PNL A & B OK 4. FEEDERS SW BOARDS TO DISTRIBUTION PNLS OK 5. TELEPHONE CONDUITS FROM NW INSIDE TO OUTSIDE 6. FEEDERS FOR PNL TB&TA OK |
| 02/09/2007 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* MANHOLE #3 VAC TEST OK MANHOLE #2 VAC TEST OK MANHOLE #1 VAC TEST OK |
| 02/09/2007 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* |
| 04/17/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 04/18/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. JIROUDEK |
| 04/19/2007 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
| 04/30/2007 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
| 05/07/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* CHECKED REMAINING CONDENSATE DRAINS OK TO INSULATE OK FOR REMAINING CEILING TILES |
| 05/07/2007 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* ROOMS 123, 124, 125, 120, 119, 118, 117, 116, 114, 115, 113, 112, 111, 110, 109, 108, 107, 106, 105 AND 100 COMPLETE. |
| 06/07/2007 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 06/07/2007 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
| 06/13/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) AIR BALANCE OK 2) OK FOR FINAL |
| 06/13/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 06/13/2007 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | ELECTRIC - CABLE DROP | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/13/2007 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/13/2007 | RIGHT OF WAY - FINAL | SDAMRON | Approved | PER EMAIL |
| 06/14/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 06/14/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 07/09/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* RECEIVED (1) COPY BACTERIA REPORT |
| 07/10/2007 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | |
| 07/10/2007 | PLUMBING - PRE SLAB | RRICH | Approved | |
| 07/12/2007 | FIRE - FINAL | LTHOMAS | Approved | |
| 08/02/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 08/02/2007 | OUTDOOR LIGHTING FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 08/02/2007 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* |
| 08/02/2007 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 08/21/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | |
| 08/21/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 08/21/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 08/22/2007 | PERMIT FINALED | LJACKSON | Approved | |
| 08/22/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 08/22/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 08/22/2007 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 08/22/2007 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 08/22/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |