Date Description Inspector Results Comments
02/09/2007 SITE - SEWER Approved IVRS - Inspection :*
02/05/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
02/01/2007 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
01/29/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
PRIVATE MANHOLE BASES POURED #1, #2, #3 OK TO STALL
FROM MANHOLE #2 TO #3 6 SDR BEDDING, LAYING, TRACER, SHADING BACKFILL OK FROM PRIVATE MANHOLE #3 6" SDR 35
BACK TO EXISTING BUILDING SEWER STUB BEDDING, LAYING, TRACER OK
1. SHALL INSTALL CLEANOUT #4 PER PLAN.
01/25/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
BEDDING, LAYING & TRACER FROM MANHOLE #2 TO 60
FROM MANHOLE #3
SHADING, BACKFILLING CONTINUES FROM
PUBLIC TO MANHOLE #2
01/24/2007 SITE - SEWER Partial Approval SHADING, BACKFILING CONTINUES PUBLIC MANHOLE TO PRIVATE MANHOLE #1, EXCAVATION, BEDDING, LAYING, TRACER CONTINUES FROM PRIVATE MANHOLE #2 APP. 180' UPSTREAM TOWARD MANHOLE #3.
01/22/2007 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
SNOW CLOSURE
01/18/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
6" SDR 35 FROM MANHOLE #1 TO PRIVATE MANHOLE #2
BEDDING, LAYING, TRACER OK
01/17/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
6" SDR 35 FROM MANHOLE #1 60' TOWARDS MANHOLE #2 BEDDING, PIPING, TRACER OK
SEE NOTES FROM 1/16/06 INSPECTION
01/16/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
PRE CONST. MEETING WITH JOE, ARIZONA EXCAVATIING
MIKE, CHESTNUT CONST.
PIPING SHALL MEET 2003 PIMA COUNTY STANDARDS,
FROM PUBLIC MANHOLE 8762-04 6" SDR 35 UPSTREAM TO PRIVATE MANHOLE #1 BEDDING, LAYING, TRACER OK

SHALL AIR TEST PIPING, VACUUM TEST NEW MANHOLES, HAVE PROVIDED VERIFICATION OF GRADE FROM ENGINEER OR SURVEYOR AT LATER DATE. SHADING ON SITE.