Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 03/02/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* PROVIDE REVISED APPROVED SITE PLAN FOR YARD WATER SHOWING INSTALLATION WITH SIZING OF PIPING, METER, AND BACKFLOW DEVICE. |
|
| 03/01/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 02/05/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) AIR TEST PUBLIC MANHOLE 6" SDR 35 PIPING TO PRIVATE MANHOLE OK 2) ? PUBLIC MANHOLE 6" SDR 35 PIPING TO PRIVATE MANHOLE 3) AIR TEST PRIVATE MANHOLE #1 TO #2 6" SDR 35 OK 4) ? PRIVATE MANHOLE #1 TO #2 6" SDR 35 OK 5) AIR TEST PRIVATE MANHOLE #2 & #3 OK 6) ? PRIVATE MANHOLE #2 TO #3 OK 7) AIR TEST PRIVATE MANHOLE #3 TO BLDG STUB OK 8) MANDREL PRIVATE MANHOLE #3 TO BLDG STUB OK 9) 3" ? FROM BLDG INTERIOR STUB UP OUT 6' PVC SCH 90 ? TO METER ? 100 PSI TEST OK 10) SHALL SEE METER THRU CORRECT BACKFLOW ASSEMBLY TIE IN |