Permit: TD-DEV-1223-00480
Permit Details
Apply Date:
12/08/2023
Applicant:
Bryan Justice
Description:
Revision 3 started 08.05.2025 - wall** Revision 2 - *Revision #1 (Setbacks) started 4/29/24* New 3-story multi-family apartment building
Permit Reviews
Permit Number - TD-DEV-1223-00480
Permit Status: Complete
Permit Description: Revision 3 started 08.05.2025 - wall** Revision 2 - *Revision #1 (Setbacks) started 4/29/24* New 3-story multi-family apartment building
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/26/2025 | DEVELOPMENT PACKAGE NEW REVISION v.1 | 03/27/2025 | APPROVED |
| 04/29/2024 | DEVELOPMENT PACKAGE NEW v.1 | 10/01/2024 | APPROVED |
| 02/27/2024 | DEVELOPMENT PACKAGE NEW v.2 | 04/05/2024 | APPROVED |
| 12/11/2023 | DEVELOPMENT PACKAGE NEW v.1 | 01/29/2024 | REQUIRES RESUBMIT |
| 08/05/2025 | DEVELOPMENT PACKAGE NEW REVISION v.1 | 09/09/2025 | REQUIRES RESUBMIT |
| 11/14/2025 | DEVELOPMENT PACKAGE NEW REVISION v.3 | 11/18/2025 | APPROVED |
| 07/30/2025 | RFI v.1 | 08/04/2025 | APPROVED |
| 10/29/2025 | DEVELOPMENT PACKAGE NEW REVISION v.2 | 11/13/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TD-DEV-1223-00480
Permit Status: Complete
Permit Description: Revision 3 started 08.05.2025 - wall** Revision 2 - *Revision #1 (Setbacks) started 4/29/24* New 3-story multi-family apartment building
| Date | Description | Comments |
|---|---|---|
| 11/18/2025 | At final inspection make sure that there is a one to two foot set back from the face of the western 8' wall to the top of the basin. The set back should include 1 to 2 percent slope toward the basin. Please reach out to chad.keller@tucsonaz.gov if there area any questions with regard to this condition. | |
| 11/18/2025 | CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT |
Outstanding Inspections
Permit Status: Complete
Permit Number: TD-DEV-1223-00480
Permite Description: Revision 3 started 08.05.2025 - wall** Revision 2 - *Revision #1 (Setbacks) started 4/29/24* New 3-story multi-family apartment building
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2025 | SITE - Stormwater Follow-up | N/A | Re-inspection required | The current Construction Track Out exiting the site at S Belvedere Ave is not on the Swppp Plan. In any case if this Trackout is approved in this location it needs to be cleaned. The rocks are clogged with dirt and it is not functioning as designed. Angular 2-3”rock, not river rock needs to be added to maintain 6’ depth, 30’ width and 50’ Length dimensions. Rock needs to be placed over Non woven black Mirafi fabric. See Detail in the Swppp plan. Waddle needs to be placed at the former entrance/exit at south end of site. The Northwest corner of the site is unprotected. The site slopes downgrade to that corner and the N screen wall ends there. That area needs a berm or other BMP to prevent storm water from exiting the site. The concrete washout area is full and starting to overflow. hardened concrete needs to be disposed of and washout needs to function as designed per plan. I talked to the superintendent about the items listed and that they need corrective action. He informed me that they are currently repairing the Track out at the south end of the site. |
| 09/18/2025 | N/A | Partial Pass | 9/18/25 18" X 10" pony wall footer for dog park behind building. Two number five continuous bars with number five verts every 48 inches. Verts are placed correctly at the start and end of walls and at expansion joints, ties correct. Compaction good- Okay to pour. Grout all below grade cells and reinforced cells and vibrate grout. |
|
| 11/14/2025 | ENGR Paving | N/A | Partial Pass | 11/14/25 South parking lot Bays and Diveline. Bays at 2.5" depth curbs correct and marked for asphalt thickness. Driveline not 100% with 3" Depth. Winrow needs clean up and a couple areas need to be shaved .5" Compaction reports for this areas not yet ready. Okay to Pave this area pending complying compaction tests of AB and driveline depth issues are fixed that I discussed with contractor. I will be out early Monday to confirm and to inspect North parking area. |
| 06/26/2025 | For trash and recycling enclosures | N/A | Partial Pass | 6/26/25 Both refuse enclosure walls are about 5'. Reinforcing correct. Okay to pour grout. Vibrate all reinforced cells. After grout is poured do not build walls past 6ft. I need to resolve issue about wall height discrepancy with my supervisor. This will be resolved soon. |
Completed Inspections
Permit Status: Complete
Permit Number: TD-DEV-1223-00480
Permit Description: Revision 3 started 08.05.2025 - wall** Revision 2 - *Revision #1 (Setbacks) started 4/29/24* New 3-story multi-family apartment building
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2025 | PDSD Engineering Division Pre-Construction SITE | Passed | informed the contractor that he needs to call in every two weeks for the swap inspections. Also informed him about the compact compaction test that he needs to be taken per plan, track out rocks in place and so are the wattles | |
| 03/11/2025 | City of Tucson (COT) Planning and Development Services Engineering (ENGR) Zoning Compliance Inspection | Passed | ||
| 11/07/2025 | Passed | |||
| 12/03/2025 | SITE - Sign Footer/Setback/Excavation Layout/Rebar | Passed | 12/3/25 Pre-grout wall inspection. Half wall south of building that separates driveway from building. Reinforcing correct. Wall will be grouted solid. Vibrate all grout. Okay to grout this wall |
|
| 12/04/2025 | Passed | |||
| 01/22/2026 | ENGR Paving | Passed | 01/22/26 Contractor pressed in 2 small swales with heat sufficient to remedy puddling at SW section of parking lot. The holes from bracing of the PV canopy columns were patched. |
|
| 02/04/2026 | For trash and recycling enclosures | Passed | ||
| 02/04/2026 | Final inspection to ensure all landscape and water harvesting SITE | Passed | 2/3/26 WHIA B will have a little berm / check dam put between it and WHIA A to make them discrete. WHIA B will also need a little more berm on the other side as well as discussed with contractor. This work will be checked at DP Final. |
|
| 02/26/2026 | SITE - Zoning Final | Passed | ||
| 02/26/2026 | LAND Landscape Appearance & Function Final | Passed | ||
| 02/26/2026 | ENGR Engineering Final | Passed |