Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address NEW:
10000 E OLD VAIL RD
Apply Date:
07/11/2025
Applicant:
Andrea Leonard
Description:
Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage

Permit Reviews

Permit Number - TD-DEV-0725-00181
Permit Status: Inspections
Permit Description: Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage
Start Date Submittal Complete Date Status  
07/11/2025 DEVELOPMENT PACKAGE NEW v.1 08/26/2025 REQUIRES RESUBMIT Review Details
11/14/2025 DEVELOPMENT PACKAGE NEW REVISION v.1 12/04/2025 APPROVED Review Details
08/29/2025 DEVELOPMENT PACKAGE NEW v.2 09/26/2025 REQUIRES RESUBMIT Review Details
09/30/2025 DEVELOPMENT PACKAGE NEW v.3 10/06/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-0725-00181
Permit Status: Inspections
Permit Description: Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage
Total Outstanding Activity Conditions - 1
Date Name
10/06/2025 CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT

Conditions

Permit Number - TD-DEV-0725-00181
Permit Status: Inspections
Permit Description: Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage
Date Description Comments
12/15/2025 Prior to Final

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0725-00181
Permite Description: Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
01/22/2026 NPPO Monitoring N/A Partial Pass Plants have been set aside in the correct quantities but not yet moved to a temporary nursery. Plants appear healthy and the plan is to have them in the ground prior to hot weather. Will continue to monitor for signs of stress.
07/28/2026 N/A Partial Pass Bollards along north basin are good to pour. Refuse enclosure bollards' placement is correct and they are concrete filled. Sprouts main pedestrian entrance bollards' placement is correct and they are concrete filled. Loading dock and utility bollards' placement is correct and they are concrete filled.
05/14/2026 For trash and recycling enclosures N/A Partial Pass I informed the contractor that they needed to punch out grout. We pulled at the bottom so we can see the grout coming out at the bottom on both trash enclosures.
05/14/2026 N/A Partial Pass OK to backfill the 8 inch roof drain 20 feet
08/14/2026 N/A Partial Pass With the exception of the curb ramp at the NW corner of building 3, all sidewalks' and curb ramps' slopes & cross-slopes are complete within acceptable tolerances.

Curb ramp at NW corner of building 3: Cross-slopes of the ramp and lower landing exceed allowable limit of 2% (ramp measures between 3 & 4%). The cross-slope needs to be corrected to a maximum of 2% on the landings and ramp.
08/10/2026 ENGR Paving N/A Partial Pass AB on North, East, and South side of building 2 and South side of building 1: depth, slopes, and compaction are good, okay to pave this area including main drive from storage facility to future refuse enclosure.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0725-00181
Permit Description: Rev 1 started 11.14.2025 - update to building numbers (5 to 4), footprints, site ** Multi-Building General Merchandise & Food Service/Food & Beverage
Total Completed Inspections - 3
Date Description Inspector Results Comments
01/05/2026 PDSD Engineering Division Pre-Construction SITE Passed Pre-Construction meeting held on-site with Geoff. Stormwater controls need to be put in place immediately. Grading work is in progress. Temp fencing is being erected currently.
"NPPO Pre-Construction" inspection should be called in asap.
"Stormwater Initial" inspection should be called in no later than 1/7/26 to confirm horizontal controls are in place prior to rainfall.
01/07/2026 SITE - Stormwater Setup and Controls Passed Initial stormwater controls are set up, site will be monitored for additional needs.
08/18/2026 ENGR Paving Passed Asphalt pavement is complete throughout. Surfaces, slopes, and curb reveals are good. Paving is complete in accordance with approved plans.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
REVISION 1 - APPROVED - FULL PLAN SET - APPROVED - 3_PLAN SET - 10000 E OLD VAIL RD - 5624_DP_V3 - STAMPED 10.06.2025_V1 - STAMPED 12.04.2025.PDF DOCUMENTS VIEW
APPROVED - 3_PLAN SET - 10000 E OLD VAIL RD - 5624_DP_V3 - STAMPED 10.06.2025.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
DEQ_FUGITIVEDUSTPERMIT_20251014_162545_V1.PDF DOCUMENTS VIEW
1_DRAINAGE REPORT - 10000 EAST OLD VAIL ROAD_V1.PDF DOCUMENTS VIEW
1_GEOTECH - OLD VAIL SHOPPING CENTER - 062425_V1.PDF DOCUMENTS VIEW
1_SWPPP - 10000 EAST OLD VAIL - SWPPP - 2025-07-09_V1.PDF DOCUMENTS VIEW
1_TIA - OLD VAIL-HOUGHTON COMMERCIAL TIA 4-17-2025_V1.PDF DOCUMENTS VIEW
REDLINE ELECTRICAL PAGES FROM 1_PLAN SET - 10000 EAST OLD VAIL - 5624_DP_V1.PDF DOCUMENTS VIEW
RESPONSE LETTER.PDF DOCUMENTS VIEW
TEP MAP.PDF DOCUMENTS VIEW