Inspection Status: Partial Pass
Inspection History: For trash and recycling enclosures
| Date |
Description |
Inspector |
Results |
Comments |
| 05/05/2026 |
For trash and recycling enclosures |
|
Partial Pass |
Trash enclosures, 2 double and 2 single: footing dimensions are good, add reinforcement to get 3 verts in the corners and 2 on the ends then reinforcement is good. Okay to pour footings. |
| 05/14/2026 |
For trash and recycling enclosures |
|
Partial Pass |
I informed the contractor that they needed to punch out grout. We pulled at the bottom so we can see the grout coming out at the bottom on both trash enclosures. |
| 06/09/2026 |
For trash and recycling enclosures |
|
Partial Pass |
Trash enclosures, both doubles: Bollards are good to pour. |
| 06/24/2026 |
For trash and recycling enclosures |
|
Partial Pass |
Refuse enclosure aprons for future building 4: subgrade, reinforcement, and depth are okay. Good to pour aprons. |
| 07/30/2026 |
For trash and recycling enclosures |
|
Partial Pass |
Two (2) refuse enclosures, north side of building 2 and north side of building 3: wall grout in single lift, weep holes are present and inspector observation of flow and vibration took place. Wall grout is complete and approved. |