Permit: TC-COM-0525-01016
Permit Details
Status:
Needs Resubmittal
Type:
Commercial Building
Address:
115 S LINDA AV
Address NEW:
115 S LINDA AV
Apply Date:
05/19/2025
Applicant:
Carina Eichorst
Description:
Rev.1: 5/27/2026 New 3-story multi-family residential building
Permit Reviews
Permit Number - TC-COM-0525-01016
Permit Status: Needs resubmittal
Permit Description: Rev.1: 5/27/2026
New 3-story multi-family residential building
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/25/2025 | COMMERCIAL REVIEW - FULL v.4 | 11/25/2025 | APPROVED |
| 08/06/2025 | COMMERCIAL REVIEW - FULL v.2 | 09/02/2025 | REQUIRES RESUBMIT |
| 11/25/2025 | RESTAMP - COMMERCIAL v.1 | 11/26/2025 | APPROVED |
| 09/02/2025 | COMMERCIAL REVIEW - FULL v.3 | 09/19/2025 | REQUIRES RESUBMIT |
| 03/31/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.3 | 04/24/2026 | APPROVED |
| 03/24/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 03/27/2026 | REQUIRES RESUBMIT |
| 03/02/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/09/2026 | REQUIRES RESUBMIT |
| 05/20/2025 | COMMERCIAL REVIEW - FULL v.1 | 06/27/2025 | REQUIRES RESUBMIT |
| 05/27/2026 | COMMERCIAL REVIEW - FULL REVISION v.1 | 06/23/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-0525-01016
Permit Status: Needs resubmittal
Permit Description: Rev.1: 5/27/2026
New 3-story multi-family residential building
Total Outstanding Activity Conditions - 8
| Date | Name |
|---|---|
| 05/20/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
| 09/09/2025 | AIR BALANCING REPORT IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 09/09/2025 | Post-Installed Anchor Inspection Report is required. |
| 09/09/2025 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR fabricated systems and elements IS REQUIRED |
| 09/09/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0525-01016
Permit Status: Needs resubmittal
Permit Description: Rev.1: 5/27/2026
New 3-story multi-family residential building
| Date | Description | Comments |
|---|---|---|
| 05/20/2025 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 05/20/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 05/20/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 09/09/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
| 10/31/2025 | Must be approved by Deputy Director Elisa Hamblin prior to permit issuance |
Outstanding Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-COM-0525-01016
Permite Description: Rev.1: 5/27/2026
New 3-story multi-family residential building
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2026 | COT - HCPL - Rough Soil | N/A | Partial Pass | 1/16/26: plumbing underground approved from GL A-C/1-3 (ok to backfill progress area, shading required) 1/20/26: plumbing underground approved from GL A-B/3-4 ok to backfill progress area, shading required) |
| 12/17/2025 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | |
| 02/08/2026 | COT - HCBU - Preslab | N/A | Partial Pass | 2/6/26: PRE-SLAB APPROVED FOR BUILDING SLAB. OKAY TO PROCEED WITH CONCRETE PLACEMENT |
| 04/10/2026 | COT - HCBU - Roof Nailing | N/A | Partial Pass | 4-10-26: roof nailing inspection only approved-Okay to dry-in. |
| 04/20/2026 | COT - HCBU - Building Above Ceiling | N/A | Partial Pass | Partial pass. 1st floor corridor SD screws and hangers. Pending 20’ south west end. Missing SD screws. 4/20/2026 |
| 05/13/2026 | COT - HCBU - Interior Shear Bracing | N/A | Canceled | Canceled per contractor. 5/13/2026 |
| 06/15/2026 | COT - HCBU - Framing | N/A | Re-inspection required | 6-15-26: framing, MEP's at room's 201- draft stop missing, missing nails at strap at entryway east wall, add 12 nails to each side of top plate splice, DWV at washer/dryer, seal penetrations at above ceiling decking along east wall , properly feed feeders through top plate at east wall and seal penetrations at top plate.decking, add plastic bushing at sub panel feeder, add nails to hold down at entryway /east wall, 202- missing deft stop, fire caulk penetrations at above ceiling decking, seal top plate penetrations at marked location, seal hvac line set penetration at above ceiling decking, missing strap at shear wall & nail strap to backing behind tub, add strap to DWV at laundry room, 203-missing draft stop, add strap to DWV at laundry, 12 nails at each side of top splices, secure pex lines within 12", ground pancake box, add plastic bushing at subpanel feeder. Stopped inspection-additional items may added. |
| 06/05/2026 | COT - HCBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 6/5/2026 2nd and 3rd floor west elevation not ready. Re walk marked areas. Exterior North east corner approved. Straps in place. |
| 04/30/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Not Ready | |
| 06/18/2026 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | |
| 06/18/2026 | COT - HCME - Mechanical Intermediate | N/A | Not Ready | 6.18.26 HVAC refrigerant lines running A2L Freon will need to be in a shaft. |
| 06/03/2026 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | 6/3/2026 partial pass. 2nd & 3rd floors pex under test. Okay to insulate hot water lines. Still need to verify straps, plates, and fire caulking at intermediate. |
Completed Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-COM-0525-01016
Permit Description: Rev.1: 5/27/2026
New 3-story multi-family residential building
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2025 | PDSD Heavy Commercial Building Division Pre-Construction Meeting | Passed | ||
| 02/13/2026 | BULD - Electrical Clearance | Passed | Temporary construction power; ensure an address label is placed on the panel. | |
| 06/26/2026 | COT - HCPL - Gas Pressure Test | Passed |