NEW: RESTAURANT IN-N-OUT BURGER
Architects:
- LANGFORD, STEVEN WALLACE
Contractors:
- IN N OUT BURGER INC
Permit Reviews
Permit Number - T05CM03034
Permit Status: C of o
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/11/2006 | RESUBMITTAL | 02/28/2006 | COMPLETED |
01/23/2007 | REVISION - - 1ST | 02/21/2007 | COMPLETED |
02/22/2007 | REVISION - - 1ST | 03/29/2007 | COMPLETED |
02/28/2006 | RESUBMITTAL | 04/25/2006 | COMPLETED |
03/29/2007 | REVISION - - 1ST | 04/11/2007 | COMPLETED |
04/11/2007 | REVISION - - 1ST | 04/11/2007 | COMPLETED |
04/25/2006 | RESUBMITTAL | 05/17/2006 | COMPLETED |
05/17/2006 | RESUBMITTAL | 05/23/2006 | COMPLETED |
05/23/2006 | RESUBMITTAL | 06/15/2006 | COMPLETED |
06/23/2005 | PLANS OK TO SUBMIT - COMM | 07/06/2005 | COMPLETED |
07/06/2005 | PLANS OK TO SUBMIT - SITE | 07/06/2005 | COMPLETED |
07/06/2005 | COMMERCIAL TI | 09/26/2005 | COMPLETED |
07/06/2005 | SITE | 05/02/2006 | COMPLETED |
09/26/2005 | COMMERCIAL TI | 12/01/2005 | COMPLETED |
10/10/2006 | REVISION - - 1ST | 10/25/2006 | COMPLETED |
12/01/2005 | RESUBMITTAL | 12/08/2005 | COMPLETED |
12/06/2006 | REVISION - - 1ST | 12/13/2006 | COMPLETED |
12/08/2005 | RESUBMITTAL | 01/11/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03034
Permit Status: C of o
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/23/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03034
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Total Completed Inspections - 47
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2006 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
08/28/2006 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* CALL FOR PRE-SLAB AFTER SETTING FD & FS BEFORE CONCRETE. |
08/28/2006 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
08/28/2006 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection :* |
10/30/2006 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* BUILDING SLAB -- OK TO POUR |
10/30/2006 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* OK 20' 4/0 IN FOOTING 1. BOND COPPER TO REBAR 250-50 "WHEN AVAILABLE" |
11/20/2006 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* MAIN PORTION OF BUILDING OK TO COVER |
12/06/2006 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* EXTERIOR SHEATHING & CLIPS - PARTIAL - SHEAR WALLS & EXTERIOR OF MAIN BUILDING -- OK TO COVER |
12/06/2006 | FRAMING | JBURGE | Approved | IVRS - Inspection :* ROOF AREA TOWERS & PARAPET WALLS - DRIVETHRU ROOF (EASTSIDE) |
12/06/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR SERVICE RECEPTACLES IN ROOF PARAPET WALLS (4) 1. PROVIDE BACK SUPPORT FOR BOXES 2. STRAP EMT GOING INTO BOXES 3. TIGHTEN ALL FITTINGS, LOCKNUTS AND SET SCREWS OK COVER AFTER CORRECTION. |
12/14/2006 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* TRASH BIN FOOTINGS OK TO POUR |
12/21/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* 1. YOU DID NOT CALL FOR PRE-SLAB INSPECTION. 2. MOST PIPES HAVE FOAM PROTECTION VISIBLE 3. ANY PIPES THAT DO NOT, WILL HAVE TO BE EXPOSED AND WRAPPED W/FOAM WHERE PASSING THROUGH CONCRETE. 4. MISSION COUPLINGS ARE REQUIRED AT PL TO C1 TRANSITIONS. 5. EXPOSE MISSION COUPLING AT ONE LOCATION BELOW SLAB TO VERIFY. 6. SUPPORT OVERHEAD PLASTIC AT 4' INTERVALS. 7. DRAINAGE FITTINGS ON RD'S 8. TEST OK ON ALL 1ST FLOOR RD'S EXCEPT AT CORRECTION OK. 9. REMOVE EXCESS FLUX W/DAMP RAG PER UPC INSTALLATION STANDARDS. 10. HAMMER ARRESTORS REQUIRED AT QUICK CLOSING VALVES. 11. PROVIDE APPROVED REVISED PLANS FOR GAS AND WATER 12. PROVIDE SPEC FOR GALV 13. CALL FOR INTERMEDIATE INSPECTION WHEN READY |
12/21/2006 | PLUMBING - ROOF DRAINS | BBENEDON | Approved | IVRS - Inspection :* |
12/21/2006 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/21/2006 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
12/21/2006 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
12/22/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* OK TO INSULATE COPPER NEATLY SEAL JOINTS W/ADHESIVE RD CORRECTION OK RECALL FOR ALL APPROPRIATE INSPECTIONS |
12/29/2006 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* |
12/29/2006 | ELECTRIC - ABOVE CEILING | IVR USER | Approved | IVRS - RI canceled |
01/19/2007 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
02/06/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
03/06/2007 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* FIRE WRAP OK OK TO COVER CURBS & HOLE THRU CEILING |
04/11/2007 | ELECTRIC - TEMP POWER FOR TEST | CCLEMENS | Approved | IVRS - Inspection :* 1) DO NOT ENERGIZE EQUIPMENT BEFORE SAFE TO DO SO 2) NOTE: NEED TO PROPERLY TERMINATE GROUNDS AT SERVICE 3) NEED WHITE FOR NEUTRAL #6 AND SMALLER, GREEN FOR GROUND OR BARE |
04/12/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* ON FINAL I.D ALL EQUIPMENT NEED TO TEST DUCT SMOKE DETECTORS HAVE DETECTORS ACCESSIBLE & READY TO TEST |
04/12/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER C. CLEMENS |
04/18/2007 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
04/18/2007 | FIRE - FINAL | LTHOMAS | Approved | |
04/18/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
04/18/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
04/19/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
04/19/2007 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
04/19/2007 | ZONING - FINAL | ACONNOR | Approved | |
04/19/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
04/19/2007 | NPPO - FINAL | ACONNOR | Approved | |
04/20/2007 | MECHANICAL - FINAL | JMILITEL | Approved | PER INSP CARD |
04/20/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | PER INSP CARD |
04/20/2007 | HEALTH DEPT - FINAL 724-7908 | RPEYTON | Approved | PER INSP CARD |
04/20/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | PER BU FINAL |
04/20/2007 | STEM WALL/RETAINING WALL | JBURGE | Approved | PER BU FINAL |
04/20/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | PER BU FINAL |
04/20/2007 | BUILDING - FINAL | JBURGE | Approved | PER INSP COPY |
04/20/2007 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
04/20/2007 | ENGINEERING - FINAL | MRUSSO | Approved | |
04/23/2007 | SIGN - FINAL | JYBARRA | Approved | |
04/25/2007 | PERMIT FINALED | LJACKSON | Approved | |
04/25/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | |
04/25/2007 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved |