Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Apply Date:
06/23/2005
Applicant:
MAZ YASAMI PM
Description:
NEW: RESTAURANT IN-N-OUT BURGER
Architects:
  • LANGFORD, STEVEN WALLACE
Contractors:
  • IN N OUT BURGER INC

Permit Reviews

Permit Number - T05CM03034
Permit Status: C of o
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Start Date Submittal Complete Date Status  
01/11/2006 RESUBMITTAL 02/28/2006 COMPLETED Review Details
01/23/2007 REVISION - - 1ST 02/21/2007 COMPLETED Review Details
02/22/2007 REVISION - - 1ST 03/29/2007 COMPLETED Review Details
02/28/2006 RESUBMITTAL 04/25/2006 COMPLETED Review Details
03/29/2007 REVISION - - 1ST 04/11/2007 COMPLETED Review Details
04/11/2007 REVISION - - 1ST 04/11/2007 COMPLETED Review Details
04/25/2006 RESUBMITTAL 05/17/2006 COMPLETED Review Details
05/17/2006 RESUBMITTAL 05/23/2006 COMPLETED Review Details
05/23/2006 RESUBMITTAL 06/15/2006 COMPLETED Review Details
06/23/2005 PLANS OK TO SUBMIT - COMM 07/06/2005 COMPLETED Review Details
07/06/2005 PLANS OK TO SUBMIT - SITE 07/06/2005 COMPLETED Review Details
07/06/2005 COMMERCIAL TI 09/26/2005 COMPLETED Review Details
07/06/2005 SITE 05/02/2006 COMPLETED Review Details
09/26/2005 COMMERCIAL TI 12/01/2005 COMPLETED Review Details
10/10/2006 REVISION - - 1ST 10/25/2006 COMPLETED Review Details
12/01/2005 RESUBMITTAL 12/08/2005 COMPLETED Review Details
12/06/2006 REVISION - - 1ST 12/13/2006 COMPLETED Review Details
12/08/2005 RESUBMITTAL 01/11/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM03034
Permit Status: C of o
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Total Outstanding Activity Conditions - 1
Date Name
06/23/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM03034
Permit Description: NEW: RESTAURANT IN-N-OUT BURGER
Total Completed Inspections - 47
Date Description Inspector Results Comments
08/17/2006 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
08/28/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
CALL FOR PRE-SLAB AFTER SETTING FD & FS BEFORE CONCRETE.
08/28/2006 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
08/28/2006 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
10/30/2006 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
BUILDING SLAB -- OK TO POUR
10/30/2006 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*
OK 20' 4/0 IN FOOTING
1. BOND COPPER TO REBAR 250-50 "WHEN AVAILABLE"
11/20/2006 ROOF NAILING JBURGE Approved IVRS - Inspection :*
MAIN PORTION OF BUILDING OK TO COVER
12/06/2006 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
EXTERIOR SHEATHING & CLIPS - PARTIAL - SHEAR WALLS & EXTERIOR OF MAIN BUILDING -- OK TO COVER
12/06/2006 FRAMING JBURGE Approved IVRS - Inspection :*
ROOF AREA TOWERS & PARAPET WALLS - DRIVETHRU ROOF (EASTSIDE)
12/06/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :
See detailed listing on site.| 999*
INSPECTION FOR SERVICE RECEPTACLES IN ROOF PARAPET WALLS (4)

1. PROVIDE BACK SUPPORT FOR BOXES
2. STRAP EMT GOING INTO BOXES
3. TIGHTEN ALL FITTINGS, LOCKNUTS AND SET SCREWS

OK COVER AFTER CORRECTION.
12/14/2006 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
TRASH BIN FOOTINGS
OK TO POUR
12/21/2006 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
1. YOU DID NOT CALL FOR PRE-SLAB INSPECTION.
2. MOST PIPES HAVE FOAM PROTECTION VISIBLE
3. ANY PIPES THAT DO NOT, WILL HAVE TO BE EXPOSED AND WRAPPED W/FOAM WHERE PASSING THROUGH CONCRETE.
4. MISSION COUPLINGS ARE REQUIRED AT PL TO C1 TRANSITIONS.
5. EXPOSE MISSION COUPLING AT ONE LOCATION BELOW SLAB TO VERIFY.
6. SUPPORT OVERHEAD PLASTIC AT 4' INTERVALS.
7. DRAINAGE FITTINGS ON RD'S
8. TEST OK ON ALL 1ST FLOOR RD'S EXCEPT AT CORRECTION OK.
9. REMOVE EXCESS FLUX W/DAMP RAG PER UPC INSTALLATION STANDARDS.
10. HAMMER ARRESTORS REQUIRED AT QUICK CLOSING VALVES.
11. PROVIDE APPROVED REVISED PLANS FOR GAS AND WATER
12. PROVIDE SPEC FOR GALV
13. CALL FOR INTERMEDIATE INSPECTION WHEN READY
12/21/2006 PLUMBING - ROOF DRAINS BBENEDON Approved IVRS - Inspection :*
12/21/2006 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/21/2006 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
12/21/2006 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
12/22/2006 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
OK TO INSULATE COPPER
NEATLY SEAL JOINTS W/ADHESIVE
RD CORRECTION OK
RECALL FOR ALL APPROPRIATE INSPECTIONS
12/29/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
12/29/2006 ELECTRIC - ABOVE CEILING IVR USER Approved IVRS - RI canceled
01/19/2007 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
02/06/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
03/06/2007 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
FIRE WRAP OK
OK TO COVER CURBS & HOLE THRU CEILING
04/11/2007 ELECTRIC - TEMP POWER FOR TEST CCLEMENS Approved IVRS - Inspection :*
1) DO NOT ENERGIZE EQUIPMENT BEFORE SAFE TO DO SO
2) NOTE: NEED TO PROPERLY TERMINATE GROUNDS AT SERVICE
3) NEED WHITE FOR NEUTRAL #6 AND SMALLER, GREEN FOR GROUND OR BARE
04/12/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
ON FINAL I.D ALL EQUIPMENT
NEED TO TEST DUCT SMOKE DETECTORS
HAVE DETECTORS ACCESSIBLE & READY TO TEST
04/12/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER C. CLEMENS
04/18/2007 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
04/18/2007 FIRE - FINAL LTHOMAS Approved
04/18/2007 FIRE SPKLR - FINAL LTHOMAS Approved
04/18/2007 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
04/19/2007 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
04/19/2007 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
04/19/2007 ZONING - FINAL ACONNOR Approved
04/19/2007 LANDSCAPE - FINAL ACONNOR Approved
04/19/2007 NPPO - FINAL ACONNOR Approved
04/20/2007 MECHANICAL - FINAL JMILITEL Approved PER INSP CARD
04/20/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved PER INSP CARD
04/20/2007 HEALTH DEPT - FINAL 724-7908 RPEYTON Approved PER INSP CARD
04/20/2007 REINFORCED MASONRY PRE-GROUT JBURGE Approved PER BU FINAL
04/20/2007 STEM WALL/RETAINING WALL JBURGE Approved PER BU FINAL
04/20/2007 BUILDING ABOVE CEILING JBURGE Approved PER BU FINAL
04/20/2007 BUILDING - FINAL JBURGE Approved PER INSP COPY
04/20/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
04/20/2007 ENGINEERING - FINAL MRUSSO Approved
04/23/2007 SIGN - FINAL JYBARRA Approved
04/25/2007 PERMIT FINALED LJACKSON Approved
04/25/2007 ELECTRIC - FINAL CCLEMENS Approved
04/25/2007 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved

Documents

File Name Document Type  
COMPLIANCECERTIFICATES.TIF DOCUMENTS VIEW
STRUCCALCS.TIF DOCUMENTS VIEW
SPECIALINSPFORMS.TIF DOCUMENTS VIEW
TESTADJUSTBALANCE.TIF DOCUMENTS VIEW
REVIEWRESPONSE.TIF DOCUMENTS VIEW
REVIEWRESPONSE_01.TIF DOCUMENTS VIEW
REVIEWRESPONSE_02.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
COFO_04-25-2007.TIF CERT OF OCC VIEW
3034-01-0001-01-REVISION001.TIF CONSTRPLANS VIEW
3034-01-0001-01-REVISION002.TIF CONSTRPLANS VIEW
3034-01-0001-01-REVISION003.TIF CONSTRPLANS VIEW
3034-01-0001-01-REVISION004.TIF CONSTRPLANS VIEW
3034-01-0001-01-REVISION005.TIF CONSTRPLANS VIEW
3034-01-0001-01-REVISION006.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW