Permit: T05CM03034

Parcel: 125100670


Addresses:

3711 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM03034

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/01/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/12/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PROVIDE GAS PIPING REVISION FOR WH #2, BEFORE CONCEALMENT.
2. CALL FOR 03050 INSPECTION HAVE REVISION OR RED LINE APPROVED PLANS FOR INSPECTION.
3. GALVANIZED OK PER ARCHITECT
4. USE LISTED PIPE CLAMPS NOT P TAPE
5. SUPPORT ABS AT EACH BRANCH AND AT NOT MORE THAN 4'
6. TEST ON DWV OK
12/22/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO INSULATE COPPER
NEATLY SEAL JOINTS W/ADHESIVE
RD CORRECTION OK
RECALL FOR ALL APPROPRIATE INSPECTIONS