Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Details
Status:
Inspections
Type:
Development Package
Apply Date:
06/21/2021
Applicant:
Description:
REV - Site/Grading/Swppp - Bautista Mixed-Use Project. 256 Apartments / Commercial Units.
Permit Reviews
Permit Number - DP21-0157
Permit Status: Inspections
Permit Description: REV - Site/Grading/Swppp - Bautista Mixed-Use Project. 256 Apartments / Commercial Units.
Start Date |
Submittal |
Complete Date |
Status |
|
05/10/2022 |
DEV PKG - RESUBMITTAL |
06/23/2022 |
COMPLETED |
Review Details |
06/21/2021 |
DEV PKG - OK TO SUBMIT |
06/30/2021 |
COMPLETED |
Review Details |
06/30/2021 |
DEV PKG |
09/10/2021 |
COMPLETED |
Review Details |
10/03/2022 |
DEV PKG - RESUBMITTAL |
10/13/2022 |
ACTIVE |
Review Details |
12/14/2021 |
DEV PKG - RESUBMITTAL |
01/18/2022 |
COMPLETED |
Review Details |
03/20/2023 |
DEVELOPMENT PACKAGE REVIEW v.1 |
04/24/2023 |
APPROVED |
Review Details |
07/13/2023 |
DEVELOPMENT PACKAGE NEW v.1 |
09/15/2023 |
APPROVED |
Review Details |
11/18/2022 |
DEVELOPMENT PACKAGE REVIEW v.2 |
12/07/2022 |
APPROVED |
Review Details |
10/27/2022 |
DEVELOPMENT PACKAGE REVIEW v.1 |
11/10/2022 |
REQUIRES RESUBMIT |
Review Details |
Outstanding Inspections
Permit Status: Inspections
Permit Number: DP21-0157
Permite Description: REV - Site/Grading/Swppp - Bautista Mixed-Use Project. 256 Apartments / Commercial Units.
Total Outstanding Inspections - 2
Last Inspection Date |
Description |
Inspector |
Results |
Comments |
03/12/2025 |
PDSD Engineering Division Pre-Construction SITE |
N/A |
Partial Pass |
contractor install the footer for the trash enclosure, but it’s not per city specifications. Contractor also installed stormwater pipes that was never inspected by the City Of Tucson contractor needs to get the engineering of record to sign off on. It also inform the contractor anymore storm pipe that’s being installed. The city needs to be notified for inspection. Also informed the contractor any open trenches needs to have a fence around it. And the spoiled piles need to have wattles around it. |
|
COT - ENGR - Stormwater |
N/A |
Requested |
|
Documents
File Name |
Document Type |
|
APPROVED R2_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
COFT - PDSD - PERMIT CARD.PDF |
DOCUMENTS |
VIEW
|
3_DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
3_DP 3RD SUBM COVER LETTER RESPONSE_V1.PDF |
DOCUMENTS |
VIEW
|
3_ONLINE SUBMITTAL PAGE, RECVD. 05.06.22_V1.PDF |
DOCUMENTS |
VIEW
|
4_COMMENT RESPONSE LETTER_V1.PDF |
DOCUMENTS |
VIEW
|
4-ONLINE SUBMITTAL PAGE, RECVD 10.03.22_V1.PDF |
DOCUMENTS |
VIEW
|
5_DP 5TH SUBM COVER LTR_V1.PDF |
DOCUMENTS |
VIEW
|
R2_1 DRAINAGE LTR_ADDENDUM 3_V1.PDF |
DOCUMENTS |
VIEW
|
R2_1 NARRATIVE_V1.PDF |
DOCUMENTS |
VIEW
|
TEP APPROVAL LETTER, 09.09.21_V1.PDF |
DOCUMENTS |
VIEW
|
TEP RECORDED PARTIAL RELEASE OF ESMT 11-18-22_V1.PDF |
DOCUMENTS |
VIEW
|
APPROVED R2_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
APPROVED R2_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
APPROVED R1_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
APPROVED R1_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
R1_1DRAINAGE_ADDENDUM2_MAR2023_V1.PDF |
DOCUMENTS |
VIEW
|
R1_1 DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
1_GEOTECH REPORT_V1.PDF |
DOCUMENTS |
VIEW
|
1_TRAFFIC IMPACT ANALYSIS - FINAL_V1.PDF |
DOCUMENTS |
VIEW
|
1_WATER AVAILABILITY LTR, TUCSON WATER, 6-8-21_V1.PDF |
DOCUMENTS |
VIEW
|
2_DRAINAGE REPORT, DECEMBER 2021_V1.PDF |
DOCUMENTS |
VIEW
|
3_DRAINAGE LETTER_ADDENDUM 1_MAY 2022_V1.PDF |
DOCUMENTS |
VIEW
|
4_DEVELOPMENT PACKAGE_V1.PDF |
DOCUMENTS |
VIEW
|
5_DEVELOPMENT PACKAGE 11.22_V1.PDF |
DOCUMENTS |
VIEW
|
TEP FACILITIES MAP, 09.09.21_V1.PDF |
DOCUMENTS |
VIEW
|
4-ONLINE SUBMITTAL PAGE, RECVD 10.03.22.PDF |
PLANS UNDER REVIEW |
VIEW
|
4_COMMENT RESPONSE LETTER.PDF |
PLANS UNDER REVIEW |
VIEW
|
4_DEVELOPMENT PACKAGE .PDF |
PLANS UNDER REVIEW |
VIEW
|
3_ONLINE SUBMITTAL PAGE, RECVD. 05.06.22.PDF |
PLANS UNDER REVIEW |
VIEW
|
3_DRAINAGE LETTER_ADDENDUM 1_MAY 2022.PDF |
PLANS UNDER REVIEW |
VIEW
|
3_DP 3RD SUBM COVER LETTER RESPONSE.PDF |
PLANS UNDER REVIEW |
VIEW
|
3_DEVELOPMENT PACKAGE.PDF |
PLANS UNDER REVIEW |
VIEW
|
2_COMMENT RESPONSE LETTER.PDF |
PLANS UNDER REVIEW |
VIEW
|
2_DEVELOPMENT PACKAGE.PDF |
PLANS UNDER REVIEW |
VIEW
|
2_DRAINAGE REPORT, DECEMBER 2021.PDF |
PLANS UNDER REVIEW |
VIEW
|
2_ONLINE SUBMITTAL PAGE, RECVD 12.06.21.PDF |
PLANS UNDER REVIEW |
VIEW
|
TEP APPROVAL LETTER, 09.09.21.PDF |
DOCUMENTS |
VIEW
|
TEP FACILITIES MAP, 09.09.21.PDF |
DOCUMENTS |
VIEW
|
1_DEV PKG APPLICATION - SIGNED.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_GEOTECH REPORT.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_DRAINAGE REPORT.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_DEVELOPMENT PACKAGE.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_ONLINE APPLICATION, RECVD 06.17.21.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_WATER AVAILABILITY LTR, TUCSON WATER, 6-8-21.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_TRAFFIC IMPACT ANALYSIS - FINAL.PDF |
PLANS UNDER REVIEW |
VIEW
|
1_PHASE I ESA ENVIRONMENTAL SITE ASSESSMENT.PDF |
PLANS UNDER REVIEW |
VIEW
|