Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Apply Date:
04/23/2020
Applicant:
KIM PRESSGROVE
Description:
NEW HOTEL
Architects:
  • DAVID RICHARD SCHUKAI
Contractors:
  • CHASSE BUILDING TEAM INC
  • CHASSE BUILDING TEAM INC***APA***

Permit Reviews

Permit Number - T20CM02530
Permit Status: C of o
Permit Description: NEW HOTEL
Start Date Submittal Complete Date Status  
01/25/2021 REVISION - - 1ST 12/17/2021 COMPLETED Review Details
04/23/2020 PLANS OK TO SUBMIT - COMM 06/01/2020 COMPLETED Review Details
06/01/2020 COMMERCIAL - NEW 08/20/2020 COMPLETED Review Details
08/25/2020 RESUBMITTAL 09/14/2020 COMPLETED Review Details
09/14/2020 RESUBMITTAL 09/16/2020 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T20CM02530
Permit Description: NEW HOTEL
Total Completed Inspections - 41
Date Description Inspector Results Comments
10/27/2020 ELECTRIC - UFER DMUNIZ Approved partial, uffers in footings.
11/06/2020 ELECTRIC - UNDERGROUND DMUNIZ Approved Partial, Secondary conduits from Switchgear to interior Electrical room (Gl12- Elevator shaft.) ok to backfill progress.
11/17/2020 PLUMBING - ROUGH, SOIL DMUNIZ Approved Approved, completion of Under slab plumbing from GL1-6 ok to backfill.
11/25/2020 BUILDING PRE-SLAB DMUNIZ Approved Partial, ok for concrete placement GL 1-7.
12/01/2020 EXCAVATION/LAYOUT REBAR & ZON ESTEVENS Approved Not ready.
12/03/2020 SHEET ROCK NAILING JBURGE Approved Partial. Level #1 corridor ceiling from South stairway to room#102. Two layers of sheet rock for two hour rating..
12/07/2020 EXT METAL CLIPS/EXT SHEATHING TGAUSP Approved Partial, North end Stairwell shear wall on ground level, ok to start Sheetrock for fire assembly.
12/10/2020 PLUMBING - YARD WTR LINE/TEST DMUNIZ Approved
12/11/2020 REINFORCED MASONRY PRE-GROUT RBOOHER Approved Approved, Elevator shaft complete.
12/15/2020 SITE - SEWER DMUNIZ Approved Partial, Private sewer lines tested and in compliance.
12/21/2020 BUILDING - PROGRESS DMUNIZ Approved Partial, South Corridor 2nd floor framing ok to start Fire barrier installation.
12/21/2020 ROOF NAILING DMUNIZ Approved Partial, Deck nailing for 3rd floor South End ok to proceed with frame.
12/23/2020 MECHANICAL - FINAL DMUNIZ Approved Partial, Four Exterior footings for Canopy Columns West Entrance. Isolated Laundry pad with Gutter trench all ok for concrete placement.
12/23/2020 FIREWALL/FIREBARRIER/FIRESTOP DMUNIZ Approved Partial, South Corridor 2nd Floor. Fire barrier for upper walls ok to Proceed on ceiling.
12/30/2020 PLUMBING - GAS PRESSURE TEST DMUNIZ Approved Partial, Gas line installed and tested from Service entrance to Mechanical room and halfway through Ground level corridor to Room 105.
01/08/2021 PLUMBING - SEWER HCS CONNECT ESTEVENS Approved
04/09/2021 ELECTRIC - OUTDOOR LIGHTING DMUNIZ Approved Approved, light piers installed and ok for concrete placement.
04/23/2021 GAS CLEARANCE DMUNIZ Approved CODE
05/10/2021 PLUMBING - ROOF DRAINS DMUNIZ Approved
05/10/2021 U VALUE FOR WINDOW DMUNIZ Approved
05/10/2021 STUCCO MESH DMUNIZ Approved
05/27/2021 MECHANICAL - INTERMEDIATE DMUNIZ Approved
05/27/2021 PLUMBING - INTERMEDIATE DMUNIZ Approved
05/27/2021 PLUMBING - ABOVE CEILING DMUNIZ Approved
05/27/2021 ELECTRIC - ABOVE CEILING DMUNIZ Approved
06/01/2021 ELECTRIC - PROGRESS DMUNIZ Approved Inspection of 1600AMP CT, MDP, DP1, DP2 OK to clear TEP ECO
06/01/2021 TEP CLEARANCE - PM DMUNIZ Approved CODE ECO/1600 AMP, CT, MDP, DP1, DP2
08/11/2021 FRAMING DMUNIZ Approved Approved
08/11/2021 ELECTRIC - INTERMEDIATE DMUNIZ Approved Approved
08/11/2021 ELECTRIC - TEMPORARY SERVICE DMUNIZ Approved - Not Applicable
08/11/2021 ELECTRIC - CONSTRUCTION POWER DMUNIZ Approved - Not Applicable
09/07/2021 FIRE - FINAL CBASALDUA Approved
09/07/2021 FIRE - ALARM FINAL CBASALDUA Approved
09/07/2021 FIRE SPKLR - FINAL CBASALDUA Approved
09/09/2021 ENGINEERING - FINAL MHERENANDEZ Approved OK FOR TCO
09/09/2021 BUILDING - FINAL DMUNIZ Approved Approved

All conditions have been met & ok to apply for CofO.
09/09/2021 BUILDING ABOVE CEILING DMUNIZ Approved 1080
09/09/2021 OUTDOOR LIGHTING FINAL DMUNIZ Approved 2090
09/09/2021 ELECTRIC - FINAL DMUNIZ Approved Approved

All conditions have been met & ok to apply for CofO.
09/09/2021 PLUMBING - FINAL DMUNIZ Approved Approved

All conditions have been met & ok to apply for CofO.
09/09/2021 CERTIFICATE OF OCCUPANCY DMUNIZ Approved Approved

All conditions have been met & ok to apply for CofO.