Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
Permit Number - T20CM02530
Inspection Description - BUILDING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/19/2021 | BUILDING - PROGRESS | Approved | APPROVED - (3RD FLOOR HALLWAY 2 HR FIRE ASSEMBLY CEILNG APPROVED.,SOUTH STAIRWELL FRAMING HOLD-DOWNS FOR 3RD & 4TH FLOORS). ALL APPROVED AS NOTED HERE-IN | |
02/12/2021 | BUILDING - PROGRESS | Partial Approval | PARTIAL, FIRE CAULKING PENETRATIONS IN CORRIDOR FROM ROOM 310-334. | |
02/10/2021 | BUILDING - PROGRESS | Not ready for Inspection | NOT READY FOR 1420 E TUCSON MARKETPLACE BL AT THIS TIME | |
02/05/2021 | BUILDING - PROGRESS | Cancelled | CANCELLED | |
02/03/2021 | BUILDING - PROGRESS | Not ready for Inspection | NOT READY CONTRACTOR CANCELLED WILL RESCHEDULE FOR 4 FEBRUARY | |
02/02/2021 | BUILDING - PROGRESS | Not ready for Inspection | NOT READY CANCELLED BY CONTRACTOR | |
02/01/2021 | BUILDING - PROGRESS | Partial Approval | PARTIAL N. 1/3 OF 4TH FLOOR DECK NAILING OK - SECTION C | |
01/29/2021 | BUILDING - PROGRESS | Partial Approval | artial. Level #2; Corridor ceiling with two layers of sheet rock for two hour rating. Level #3; joists hangers in corridor from room 301-334. | |
01/28/2021 | BUILDING - PROGRESS | Partial Approval | Partial. Level #1; North and South Stairwells: framed and hold downs in place. Ok to insulate and cover walls. East and South mechanical room walls framed. Ok to cover progress areas. | |
01/25/2021 | BUILDING - PROGRESS | Partial Approval | Partial. Level #3; joists clips in corridor at Room Units 210 - 222. | |
01/21/2021 | BUILDING - PROGRESS | Partial Approval | Partial. (01035). Level #1; Room Units and laundry room areas, all areas except for lobby and amenities areas. | |
01/19/2021 | BUILDING - PROGRESS | Partial Approval | Partial. Level #1; Center area, hangers and R C Channel are in place. Ok to cover progress areas. Level #3 South Corridor; Hangers (LUS26 and ESR 2523) in place. Room #303, South exterior wall two hour fire rated wall (2 layers of 5/8” sheet rock) at South Stairwell. Ok to tape progress area. | |
01/13/2021 | BUILDING - PROGRESS | Partial Approval | Partial approval South corridor 1st floor corridor joist hangers OK for drywall room 111 to 124 ceiling grid to 2nd floor deck. | |
01/06/2021 | BUILDING - PROGRESS | Partial Approval | Partial approval for; 1. 1st and 2nd floor hallways rooms 124 north to stairway, and 211 south. Drywall screws and double layer overlap above grid including penetrations for exhaust ducts fire seal at rim boards 2. Partial approval for Electrical room in south east corner framing 1st floor ok to drywall 3. Partial approval for Mechanical room adjoining electrical room framing 4. Partial approval for stairwell in the south west corner framing ok to drywall 1st floor, not areas covering first to 2nd floor framing hold down connections or electrical |
|
12/21/2020 | BUILDING - PROGRESS | Partial Approval | Partial, South Corridor 2nd floor framing ok to start Fire barrier installation. | |
12/14/2020 | BUILDING - PROGRESS | Partial Approval | Partial, North end Corridor on Ground level. Framing above ceiling, ok to start installing Fire barrier. |