Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
9615 E OLD SPANISH TR
Apply Date:
02/20/2003
Applicant:
GREG SHANNON
Description:
NEW:RETAIL STORE
Architects:
  • WOBKEN, TERRY GEORGE
Contractors:
  • ADOLFSON AND PETERSON INC ,

Permit Reviews

Permit Number - T03CM00901
Permit Status: C of o
Permit Description: NEW:RETAIL STORE
Start Date Submittal Complete Date Status  
02/20/2003 PLANS OK TO SUBMIT - COMM 07/03/2003 COMPLETED Review Details
02/20/2003 COMMERCIAL NEW 04/30/2003 COMPLETED Review Details
05/23/2003 RESUBMITTAL 07/08/2003 COMPLETED Review Details
06/18/2003 SITE 08/01/2003 COMPLETED Review Details
07/11/2003 RESUBMITTAL 07/25/2003 COMPLETED Review Details
07/25/2003 RESUBMITTAL 08/01/2003 COMPLETED Review Details
09/26/2003 REVISION 09/26/2003 COMPLETED Review Details
09/26/2003 REVISION 10/21/2003 COMPLETED Review Details
10/09/2003 REVISION 11/05/2003 COMPLETED Review Details
11/26/2003 3RD PARTY REVIEW-REVISION/OTHER 12/02/2003 COMPLETED Review Details
12/22/2003 3RD PARTY REVIEW-REVISION/OTHER 12/29/2003 COMPLETED Review Details
12/26/2003 3RD PARTY REVIEW-REVISION/OTHER 01/09/2004 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T03CM00901
Permit Description: NEW:RETAIL STORE
Total Completed Inspections - 43
Date Description Inspector Results Comments
08/28/2003 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection 0000*/ OK 20' GRND ROD AND CADWELD AT EDC -1.
10/17/2003 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection 0000*
11/07/2003 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*/ 1) PACK SLAB OK. 2) EAST END OF GARDEN CENTER OK.
11/18/2003 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection 0000*/ 1) MENS AND WOMENS REST ROOM 115 AND 116 STOOL WALL WASTE AND VENT WATER TEST AND WATER PRESSURE TEST OK THRU ROOF. VENTS IN WALL AND OVERHEAD IN THIS AREA WILL REQUIRE CITY APPROVAL DRAWINGS BECAUSE CONTRACTOR HAD TO UP SIZE TO MEET CODE.
11/18/2003 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection 0000*
12/03/2003 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved
12/03/2003 PLUMBING - TEMP POWER FOR TEST RRICH Approved
12/03/2003 ELECTRIC - TEMP POWER FOR TEST JORTA Approved
12/03/2003 BUILDING - TEMP POWER FOR TEST LHANLY Approved
12/04/2003 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection 0000*
12/10/2003 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000* RAMP @ NE NOT REQUIRED TO BE ACCESSIBLE PER IBC CHAP 11. MSIN ENTRANCE AND GARDEN EXITS PROVIDE COMPLIANCE WITH 1104 & 1105 OF IBC
12/15/2003 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection 0000*/ ROUGH SOIL WTR TEST ON ADDED 3" FLOOR SINK IN FOOD SERVICES 123 THRU REVENT APP. 10 PSI PRESSURE TEST APP FOR GAS WTR HTR, TWO SPACE HTRS, AND GAS GENERATOR.
12/15/2003 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection 0000*
12/15/2003 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*/ ROOM 123 APP. MENS/WOMENS, MAIN ENTRANCE?, N & S ABOVE EXITS,
12/16/2003 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection 0000*/ 60 PSI TEST ON 5 PSI GAS SYSTEM APP. - COMPLETE.
12/16/2003 ROOF NAILING LHANLY Approved IVRS - Inspection 0000* NORTH CANOPY ROOF OK TO CLAY IN
12/24/2003 MECHANICAL - ABOVE CEILING JMILITEL Approved
12/24/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0999*
12/24/2003 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000* NORTH CANOPY & REMAINING CORBELS
12/24/2003 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection 0000*
12/24/2003 FRAMING LHANLY Approved IVRS - Inspection 0000* EAST CANOPY DECK & COLUMNS.
12/24/2003 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
12/31/2003 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*/ OK POWER POLES AND RELOC. SYSTEM AT ELECTRONICS, SPORTING GOODS, TOYS, GAMES, KITCHE, SMALL ELECTRICS, FURNITURE, HOME OFFICE, PARTIAL CUSTOMER SERVICE AREA. INSTALL SUPPORT AT J BOXES FOR RELOC WITHIN 12".
01/09/2004 ELECTRIC - TEMPORARY SERVICE RMAJUTA Approved SENT TO TEP ON 01/12/04 AM
01/21/2004 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection 0000*/ INSPECTED CONDENSATES, REFRIGERATION LINES AND EQUIPMENT. RELEIF AIR LOUVERS RESTRICTED IN GENERATOR ROOM
01/23/2004 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection 0000*/ GAS CARD DROPPED AT METER STUB
01/28/2004 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
01/28/2004 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*
01/28/2004 FIRE SPKLR - FINAL JEGAN Approved IVRS - Inspection 0000*
01/28/2004 FIRE SPKLR - OH PIPING & HYDRO JEGAN Approved IVRS - Inspection 0000*
01/28/2004 FIRE SPKLR - UG PIPING FLUSH JEGAN Approved IVRS - Inspection 0000*
01/28/2004 FIRE SPKLR - UG, PIPING, HYDRO JEGAN Approved IVRS - Inspection 0000*/ 1) OK C OF O
02/05/2004 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*/ 1) ALL CORRECTIONS HAVE BEEN MADE 2) OK FOR C OF O
02/05/2004 MECHANICAL - HOODS JMILITEL Approved
02/12/2004 PLUMBING - FINAL LHANLY Approved IVRS - Inspection 0000*/ corrections made: ONE COPY OF PIMA CO. HCS RELEASE. ONE COPY OF BACTERIA REPORT FOR H20 POTABLE SYSTEM. THIRTEEN COPIES OF BACKFLOW CERTIFICATIONS.
02/12/2004 PLUMBING - SEWER HCS CONNECT LHANLY Approved
02/12/2004 PLUMBING - YARD WTR LINE/TEST LHANLY Approved
02/27/2004 NPPO - FINAL ACONNOR Approved
02/27/2004 LANDSCAPE - FINAL ACONNOR Approved
02/27/2004 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*
03/17/2004 ENGINEERING - FINAL DROBERTS Approved
06/23/2004 RIGHT OF WAY - FINAL DLEE Approved
09/03/2004 PERMIT FINALED LLESNY Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
001_A8A.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
C OF O_09-03-2004.TIF CERT OF OCC VIEW
TEMP C OF O_02-27-2004.TIF CERT OF OCC VIEW
TEMP C OF O_01-28-2004.TIF CERT OF OCC VIEW