Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 12/24/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 11/07/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 10/17/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* RAMP WALLS NORTH SIDE OK |
| 10/16/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* 1) F-M/5-11. 2) PLEASE REWELD DECK WHERE INDICATED DURING WALK THRU. 3) SEE DETAIL3/SG FOR REQUIRED WELDS WITHIN 10' OF CORNERS. |
| 10/10/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 10/01/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/26/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/23/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/22/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/20/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* PANELS 74-87 & T-4,5,6 |
| 09/18/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* TILT UP WALLS 54-73 |
| 09/16/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/04/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/03/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 08/26/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* CONST PAD IN DOCK AREA PER REVISION ( LINEM) |
| 08/25/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* 1) f2 footings line 122) F2 FOOTINGS NEAR LINEB,2. 3) PERIMETER FROM M-11 TO H-1. 4) LINE 0.1 ERECTION PADS PER R F I AND WALL FOOSTSING 5) F2 FOOTING LINE R 1 |
| 08/21/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/20/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* 1) F3 FOOTINGS LINE 1 & LINE E.4 CORRECTED. 2) F2 COL FOOTINGS LINE 0.1 BETWEEN B.2 & D (5 EACH). 3) LINE 11 AND LINE M/10-11. 4) RAMP FOOTING J-6 NORTH OF II OK TO POUT IF SPEC INSP CONFIRMS PLACEMENT. |
| 08/19/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* LINE 1/A-H -F3 FOOTIINGS REQUIRE 7 #6 EACH WAY NOT #5. LINE G.5/0.3-1 LINE 2 ISOLATED FOOTINGS LINE A 1-11 LINE 1/A-C LINE 0.1 5 EA ISOLATED FOOTINGS E.4-> D.1 LINE Z SCREEN WALL FOOTINGS |
| 08/14/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
SEE HYLIGHTED AREAS ON APPROVED PLANS |