Permit: T03CM00901

Parcel: 133552310

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/15/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ ROUGH SOIL WTR TEST ON ADDED 3" FLOOR SINK IN FOOD SERVICES 123 THRU REVENT APP. 10 PSI PRESSURE TEST APP FOR GAS WTR HTR, TWO SPACE HTRS, AND GAS GENERATOR.
12/10/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) VENT THRU ROOF FOR SALES FLOOR COOLER/FREEZER CASES WATER TEST APPROVED. CAPS ON ALL OLD WASTE AND VENT FOR THIS AREA OK. DETAIL 5 ON M9
12/04/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ ABOVE CEILING FROM 'K' LINE WEST IS APPROVED. NEW COMBINATION WASTE AND VENT WTR TEST OK FROM K-H LINE NORTH OF 7 LINE [UNDERGROUND ONLY] ITEMS 4&5 ON INSP. DATED 8/28/03, HAVE APPROVED PLANS. 03005 - WAITING ONLY ON FLOOR SINK IN STARBUCKS.
11/25/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* ALL SALES FLOOR
11/24/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
11/14/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) WASTE AND VENT WATER TEST OK FOR MENS LAV AND WOMENS LAV WALLS THRU ROOF, ROOMS 115 AND 116. H2O AIR TEST85 PSI OK. BOTH AREAS. JANITOR #119, EWF NORTH OF 119, WATER TEST THRU ROOF OK. H2O AIR TEST 85 PSI THIS AREA OK. 2) FOOD SERVICES AREA WASTE AND VENT IN WALL WATER TEST OK. ABOVE CEILING NEEDS TO BE UPSIZED PER CODE. 3) LOUNGE 157 SINK WASTE AND VENT IN WALL WATER TEST OK. H2O OK. ABOVE CEILING NEEDS TO BE UPSIZED PER CODE. 4) STORAGE #168 MOP SINK WASTE AND VENT WATER TEST THRU ROOF OK. H2O TEST OK. 5) GREASE TRAP VENT TO BE TESTED AND APPROVED DRAWING FOR CHANGE TO WALL ON SITE. 6) EWF IN S.W. CORNER OF GARDEN CENTER WASTE AND VENT WATER TEST THRU ROOF OK. H2O TEST OK.
11/13/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 6" RD AND OFRD IN S.E. CORNER OF GARDEN CENTER 171 WATER TEST OK.
11/07/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
11/03/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/1) WASTE AND VENT THRU ROOF FOR RESTROOM #143 AND DRAIN IN PUMP ROOM WATER TEST IS OK ONLY. 2) DRAINS FOR WALK IN COOLERS IN SAME AREA REQUIRE CITY APPROVED DRAWINGS FOR ROUGH SOIL AND INTERMEDIATE INSPECTIONS. 3) COMBINATION WASTE AND VENT SECTION FOR REFRIGERATED CASES REQUIRES CITY APPROVED DRAWING FOR ROUGH SOIL AND INTERMEDIATE INSPECTIONS. CONTRACTOR SHALL NOT COVER ANY UNINSPECTED AREAS.
10/28/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*