Permit: T03CM00901

Parcel: 133552310

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
01/09/2004 STEM WALL/RETAINING WALL Approved IVRS - Inspection 0000*
10/17/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
10/01/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/TILT(?) PANELS 17 - 21 OK TO PLACE WHEN SPECIAL INSPECTOR CONFIRMS EXTRA RE-INFORCMENT AROUND BEAM EMBED ON PANEL 17.
09/26/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ PANELS 84,87,88, AND 90-109 AND 1-16, OK TO POUR, AFTER MINOR ADJUSTMENTS MADE AT BOTTOM OF 90 AND 109.
09/23/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 1) PANELS 83, 85, 86, 89, T4, Y5, T6 OK. 2) OTHER PANELS HAVE CONSISTENT PROBLEMS WITH CLEARANCE FROM RING TIES, CLEARANCE BETWEEN ADJACENT BARS AND MISSING EDGE BARS.
09/22/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 1) PANELS 54-82 OK TO POUR WHEN SPECIAL INSP CONFIRMS NOTES BELOW.
A)#65 REQUIRES ANOTHER HORIZONTAL AT TOP OF OPENING. B) #71 REQUIRES CLEARANCE BETWEEN EDGE BARS. C) #75 REQUIRES 3/4" CLEAR TO COLUMN STEEL.
09/16/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* T.IT PANELS 22-53 1) FINAL ADJUSTMENTS OF PERIMETER BARS TO COMPLY WITH ACI318/7.6 BEING DONE @ THIS TIME. PANELS MAY BE POURED WHEN SPEC INSP SPEC INSP CONFIRMS.
09/15/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 1) PEREMETER BARS NEED TO BE PLACED IN EACH FACE, NOT TIED IN CENTER. 2) 2 EACH #4 DIAGONALS REQUIRED IN EACH FACE @ EACH CORNER OF OPENINGS. 3) PULL JAMB COLUMNS OVER TO 2" CLEAR FROM OPENINGS. (CURRENTLY 4"- 6")
08/26/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* CANOPY PEDISTALS LINE 0.1,LINE 12, LINE N OK TO CLOSE & POUR
08/20/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 5 EACH COLUMN PIER LINE0.1 D-E