Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0523-01382
Permit Details
Apply Date:
05/25/2023
Applicant:
Description:
one story medical device sterilization facility
Permit Reviews
Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/19/2023 | COMMERCIAL REVIEW - FULL v.1 | 11/14/2023 | REQUIRES RESUBMIT |
12/05/2023 | COMMERCIAL REVIEW - FULL v.1 | 01/02/2024 | REQUIRES RESUBMIT |
02/09/2024 | COMMERCIAL REVIEW - FULL v.3 | 02/27/2024 | APPROVED |
11/22/2023 | RESTAMP - COMMERCIAL v.1 | 11/27/2023 | APPROVED |
01/09/2024 | COMMERCIAL REVIEW - FULL v.2 | 02/07/2024 | REQUIRES RESUBMIT |
08/07/2023 | COMMERCIAL REVIEW - FULL v.3 | 08/15/2023 | REQUIRES RESUBMIT |
02/27/2024 | RESTAMP - COMMERCIAL v.1 | 03/06/2024 | APPROVED |
08/23/2023 | RESTAMP - COMMERCIAL v.1 | 08/29/2023 | APPROVED |
08/16/2023 | COMMERCIAL REVIEW - FULL v.4 | 08/23/2023 | APPROVED |
08/05/2024 | COMMERCIAL REVIEW - FULL REVISION v.1 | 09/05/2024 | APPROVED |
05/26/2023 | COMMERCIAL REVIEW - FULL v.1 | 06/27/2023 | REQUIRES RESUBMIT |
11/20/2023 | COMMERCIAL REVIEW - FULL v.2 | 11/22/2023 | APPROVED |
07/05/2023 | COMMERCIAL REVIEW - FULL v.2 | 08/03/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Total Outstanding Activity Conditions - 16
Date | Name |
---|---|
08/14/2023 | AIR BALANCING/COMMISSIONING REPORT IS REQUIRED. |
08/14/2023 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. |
08/14/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
08/14/2023 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
08/14/2023 | ??? Designs must be submitted and approved prior to ... |
08/14/2023 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
08/14/2023 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
08/14/2023 | Stair Designs must be submitted and approved prior to... |
08/14/2023 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
08/14/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
08/14/2023 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |
Conditions
Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Date | Description | Comments |
---|---|---|
07/05/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. | |
07/28/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Fees Paid
Permit Number: TC-COM-0523-01382
Permite Description: one story medical device sterilization facility
Total Outstanding Inspections - 12
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2024 | COT - HCPL - Plumbing Roof Drains | N/A | Not Ready | |
03/08/2024 | COT - HCBU - Preslab | N/A | Canceled | 3/8/24: canceled per John |
07/12/2024 | COT - LCPL - Plumbing Progress | N/A | Partial Pass | 7/12/24: 200' of 2" pipe and 300' of 1" chill water lines are under 150 pound air pressure test with no leaks. Pipe fitters are wrapping pipes before concrete pour. |
08/09/2024 | COT - HCPL - Sewer | N/A | Deferred | 8/9/24:needed storm drain inspection |
08/15/2024 | COT - HCPL - Plumbing Above Ceiling | N/A | Partial Pass | 8/15/8/15/24: okay to proceed in all areas except hallway in main office where water lines cross from janitors closet to bathrooms. Also need inspection for hose bib in scrubber dump room |
08/20/2024 | COT - HCME - Mechanical Intermediate | N/A | Partial Pass | RTU 1 office area main runs. 106, 109, 107, 105, 104, 103, 102, 101, 125, 124. Pending room 108, 115, and 116. Okay to proceed progress areas. 8/20/2024 |
08/26/2024 | COT - HCEL - Electrical Progress | N/A | Partial Pass | 8/26/24: south and west mezzanine treatment cell exterior walls okay to pour concrete |
09/06/2024 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | 9/5/24: 9/5/24: mezzanine rotor room west and north walls okay to place concrete. Office areas and bathrooms okay to cover |
09/18/2024 | COT - HCEL - Electrical Underground | N/A | Partial Pass | Secondary feeders for Transformer 1 and 2. Cam locks for portable generators and permanent generator. Okay to backfill. Shading required. 9/18/2024 |
08/15/2024 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | 8/15/24: okay to proceed in all areas except hallway in main office where water lines cross from janitors closet to bathrooms. Also need inspection for hose bib in scrubber dump room |
09/19/2024 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | Main office areas. Drywall inspection. 5/8" type x and doc office. Approved. Okay to proceed progress areas. 9/19/2024 |
03/22/2024 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Canceled | 3/22/24: canceled per contractor |
Completed Inspections
Permit Status: Fees Paid
Permit Number: TC-COM-0523-01382
Permit Description: one story medical device sterilization facility
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/05/2024 | COT - HCBU - Framing | Passed | ||
08/07/2024 | BULD - Electrical Clearance | Passed | Electrical panel is properly installed on pedestal next to transformer. Okay to proceed with providing temporary electrical power to the job site. |