Permit Details

Status:
Fees Paid
Type:
Commercial Building
Apply Date:
05/25/2023
Applicant:
Description:
one story medical device sterilization facility

Permit Reviews

Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Start Date Submittal Complete Date Status  
10/19/2023 COMMERCIAL REVIEW - FULL v.1 11/14/2023 REQUIRES RESUBMIT Review Details
12/05/2023 COMMERCIAL REVIEW - FULL v.1 01/02/2024 REQUIRES RESUBMIT Review Details
02/09/2024 COMMERCIAL REVIEW - FULL v.3 02/27/2024 APPROVED Review Details
11/22/2023 RESTAMP - COMMERCIAL v.1 11/27/2023 APPROVED Review Details
01/09/2024 COMMERCIAL REVIEW - FULL v.2 02/07/2024 REQUIRES RESUBMIT Review Details
08/07/2023 COMMERCIAL REVIEW - FULL v.3 08/15/2023 REQUIRES RESUBMIT Review Details
02/27/2024 RESTAMP - COMMERCIAL v.1 03/06/2024 APPROVED Review Details
08/23/2023 RESTAMP - COMMERCIAL v.1 08/29/2023 APPROVED Review Details
08/16/2023 COMMERCIAL REVIEW - FULL v.4 08/23/2023 APPROVED Review Details
08/05/2024 COMMERCIAL REVIEW - FULL REVISION v.1 09/05/2024 APPROVED Review Details
05/26/2023 COMMERCIAL REVIEW - FULL v.1 06/27/2023 REQUIRES RESUBMIT Review Details
11/20/2023 COMMERCIAL REVIEW - FULL v.2 11/22/2023 APPROVED Review Details
07/05/2023 COMMERCIAL REVIEW - FULL v.2 08/03/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Total Outstanding Activity Conditions - 16
Date Name
08/14/2023 AIR BALANCING/COMMISSIONING REPORT IS REQUIRED.
08/14/2023 Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents.
08/14/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
08/14/2023 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
08/14/2023 ??? Designs must be submitted and approved prior to ...
08/14/2023 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
08/14/2023 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
08/14/2023 Stair Designs must be submitted and approved prior to...
08/14/2023 SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
08/14/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
08/14/2023 SPECIAL INSPECTION FOR WELDING IS REQUIRED.

Conditions

Permit Number - TC-COM-0523-01382
Permit Status: Fees paid
Permit Description: one story medical device sterilization facility
Date Description Comments
07/05/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.
07/28/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Fees Paid
Permit Number: TC-COM-0523-01382
Permite Description: one story medical device sterilization facility
Total Outstanding Inspections - 12
Last Inspection Date Description Inspector Results Comments
02/23/2024 COT - HCPL - Plumbing Roof Drains N/A Not Ready
03/08/2024 COT - HCBU - Preslab N/A Canceled 3/8/24: canceled per John
07/12/2024 COT - LCPL - Plumbing Progress N/A Partial Pass 7/12/24: 200' of 2" pipe and 300' of 1" chill water lines are under 150 pound air pressure test with no leaks. Pipe fitters are wrapping pipes before concrete pour.
08/09/2024 COT - HCPL - Sewer N/A Deferred 8/9/24:needed storm drain inspection
08/15/2024 COT - HCPL - Plumbing Above Ceiling N/A Partial Pass 8/15/8/15/24: okay to proceed in all areas except hallway in main office where water lines cross from janitors closet to bathrooms. Also need inspection for hose bib in scrubber dump room
08/20/2024 COT - HCME - Mechanical Intermediate N/A Partial Pass RTU 1 office area main runs. 106, 109, 107, 105, 104, 103, 102, 101, 125, 124. Pending room 108, 115, and 116. Okay to proceed progress areas. 8/20/2024
08/26/2024 COT - HCEL - Electrical Progress N/A Partial Pass 8/26/24: south and west mezzanine treatment cell exterior walls okay to pour concrete
09/06/2024 COT - HCEL - Electrical Intermediate N/A Partial Pass 9/5/24: 9/5/24: mezzanine rotor room west and north walls okay to place concrete. Office areas and bathrooms okay to cover
09/18/2024 COT - HCEL - Electrical Underground N/A Partial Pass Secondary feeders for Transformer 1 and 2. Cam locks for portable generators and permanent generator. Okay to backfill. Shading required. 9/18/2024
08/15/2024 COT - HCPL - Plumbing Intermediate N/A Partial Pass 8/15/24: okay to proceed in all areas except hallway in main office where water lines cross from janitors closet to bathrooms. Also need inspection for hose bib in scrubber dump room
09/19/2024 COT - HCBU - Firewall/Fire Barrier/Firestop N/A Partial Pass Main office areas. Drywall inspection. 5/8" type x and doc office. Approved. Okay to proceed progress areas. 9/19/2024
03/22/2024 COT - HCBU - Excavation/Rebar/Zoning N/A Canceled 3/22/24: canceled per contractor

Completed Inspections

Permit Status: Fees Paid
Permit Number: TC-COM-0523-01382
Permit Description: one story medical device sterilization facility
Total Completed Inspections - 2
Date Description Inspector Results Comments
08/05/2024 COT - HCBU - Framing Passed
08/07/2024 BULD - Electrical Clearance Passed Electrical panel is properly installed on pedestal next to transformer. Okay to proceed with providing temporary electrical power to the job site.

Documents

File Name Document Type  
REV 3_1_PLAN SET_V1.PDF DOCUMENTS VIEW
SPAPP-REV3_1_REVISION NARRATIVE-2024-08-05_V1.PDF DOCUMENTS VIEW
REV2_3_ONSITE UTILITY PLAN_V1.PDF DOCUMENTS VIEW
3_PLAN SET_V2.PDF DOCUMENTS VIEW
CONS-REV1_2_PLAN SET_V2.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-REV1_2_PLAN SET_V2.PDF DOCUMENTS VIEW
REV1_2_REVISION NARRATIVE_V2.PDF DOCUMENTS VIEW
REV1_2_REVISION NARRATIVE_V2.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
3_PLAN SET_V2.PDF DOCUMENTS VIEW
1_STRUCTURAL CALCULATIONS_V1.PDF DOCUMENTS VIEW
1_GEOTECHNICAL REPORT_V1.PDF DOCUMENTS VIEW
1_CONTRACTOR IDENTIFICATION LETTER_V1.PDF DOCUMENTS VIEW
1_CONTRACTOR BOND_V1.PDF DOCUMENTS VIEW
1_COMCHECK ENVELOPE_V1.PDF DOCUMENTS VIEW
CONS-1_PLAN SET_V1.PDF DOCUMENTS VIEW