Permit: T17CM03512
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
1151 E HERMANS RD #921
Address NEW:
1151 E HERMANS RD #921
Apply Date:
05/04/2017
Applicant:
N/A
Description:
NEW MULTI PURPOSE BLDG
Architects:
- JENNIFER CARR
Contractors:
- BRASFIELD AND GORRIE L L C ,
Permit Reviews
Permit Number - T17CM03512
Permit Status: C of o
Permit Description: NEW MULTI PURPOSE BLDG
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/04/2017 | PLANS OK TO SUBMIT - COMM | 05/08/2017 | COMPLETED |
| 05/08/2017 | COMMERCIAL - NEW | 06/07/2017 | COMPLETED |
| 06/07/2017 | RESUBMITTAL | 06/16/2017 | COMPLETED |
| 06/16/2017 | REVISION - - 1ST | 07/17/2017 | COMPLETED |
| 07/17/2017 | REVISION - - 1ST | 09/19/2017 | COMPLETED |
| 09/19/2017 | REVISION - - 1ST | 09/21/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM03512
Permit Status: C of o
Permit Description: NEW MULTI PURPOSE BLDG
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/04/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T17CM03512
Permit Description: NEW MULTI PURPOSE BLDG
Total Completed Inspections - 39
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2017 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | SEE HIGHLIGHTED AREA B BATHROOMS ONLY |
| 12/06/2017 | PLUMBING - PRE SLAB | RCAMACHO | Approved | AFTER HOURS APA ACCOUNT $165.00 GRID LINES A-E FROM 1-3 GROUND FLOOR ONLY |
| 12/06/2017 | PLUMBING - PRE SLAB | RCAMACHO | Approved | WORK NOT COMPLETE |
| 12/06/2017 | ELECTRIC - UFER | RCAMACHO | Approved | WORK NOT COMPLETE |
| 12/06/2017 | ELECTRIC - UNDERGROUND | RCAMACHO | Approved | WORK NOT COMPLETE |
| 12/15/2017 | BUILDING PRE-SLAB | RCAMACHO | Approved | COLUMN POUR BACKS A/1, B/1, C/1, D/1, A/2, A/3, A/4, A/5, A/6 AND A/7 ONLY |
| 01/23/2018 | ROOF NAILING | rbaldwin | Approved | |
| 02/08/2018 | STUCCO MESH | rbaldwin | Approved | not applicable |
| 06/15/2018 | MECHANICAL - UNDERGROUND | RCAMACHO | Approved | |
| 06/15/2018 | U VALUE FOR WINDOW | RCAMACHO | Approved | |
| 07/26/2018 | PLUMBING - INTERMEDIATE | RCAMACH1 | Approved | |
| 09/26/2018 | FRAMING | RCAMACHO | Approved | |
| 10/02/2018 | MECHANICAL - PROGRESS | RCAMACHO | Approved | |
| 10/02/2018 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | |
| 10/02/2018 | MECHANICAL - HYDRONIC PIPING | RCAMACHO | Approved | |
| 10/02/2018 | PLUMBING - PROGRESS | RCAMACHO | Approved | |
| 10/02/2018 | ELECTRIC - PROGRESS | RCAMACHO | Approved | |
| 10/04/2018 | MECHANICAL - ABOVE CEILING | RCAMACHO | Approved | |
| 10/04/2018 | PLUMBING - ABOVE CEILING | RCAMACHO | Approved | |
| 10/04/2018 | BUILDING - PROGRESS | RCAMACHO | Approved | |
| 10/04/2018 | SHEET ROCK NAILING | RCAMACHO | Approved | |
| 10/04/2018 | BUILDING ABOVE CEILING | RCAMACHO | Approved | |
| 10/09/2018 | PLUMBING - GAS PRESSURE TEST | RCAMACHO | Approved | |
| 10/11/2018 | PLUMBING - GAS PRESS TEST FNL | RCAMACHO | Approved | OK TO CLEAR GAS |
| 10/11/2018 | ELECTRIC - TEMP POWER FOR TEST | RCAMACHO | Approved | |
| 10/11/2018 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | |
| 10/11/2018 | ELECTRIC - CONSTRUCTION POWER | RCAMACHO | Approved | |
| 10/11/2018 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | |
| 10/12/2018 | GAS CLEARANCE | RCAMACHO | Approved | |
| 10/18/2018 | FIRE - ALARM FINAL | JPEELDAVIS | Approved | Add h/s outside storage A0110 Change H/S to Strobe only in bathrooms 1B0110, 1B0130, and change to 30 candella Change H/s to Strobe only wellness room 1 B0255 Change Front Lobby HS to 95 Candella Change 2 h/s office 1B0200 from 15 cd to 75 cd Change Conference room 1B0315h/s to 30 candella All team rooms in the building need to be strobe only and 15 candella Add H/S to corridor outside conference #9 Office 1163? H/S not working properly conference room #6 change from 15cd to 30cd Bathroom 1J0310 and 1J0320 need to be strobe only change h/s in wellness room #1B0655 to strobe only Add manual pull station to office 1B0200 by north door Conference room # 15 is 15 csandella and needs to be 30 Bathroom #1C0545 & 1C0525 need to be changed to strobe only Office #13 hs back area is 15 cd and needs to be 75 cd Office #12 front h/s is not working and needs to be replaced Vestibule # 10 replace the h/s with a 15 cd strobe only 2 H/s Main electrical room need to be raised to the proper height All power supplies to have a red breaker labels Fire Alarm Mag locks on the front door need to be connected to the fire alarm Level 2 area add notification corridor 2.3 by conference room 200295 All Team rooms 5,7,9& 10 need to be changed to strobe only devices Conference Room # 17 & 18 need to be changed to 30 candella East side restroom needs to be changed to 30 candella |
| 10/18/2018 | FIRE SPKLR - FINAL | JPEELDAVIS | Approved | Replace missing esuctcheons and add 2 heads in the electrical rooms 3rd floor Office # 5 has a leaking head NW Waiting has a painted head Electrical rooms first floor need to have 2 heads added to under the duct work |
| 10/19/2018 | MECHANICAL - FINAL | MRAMBER | Approved | |
| 10/22/2018 | BUILDING - FINAL | RCAMACHO | Approved | Pending all revisions to building pending chlorination report to Bob Sherry okay to apply for temporary C of o |
| 10/22/2018 | ELECTRIC - FINAL | RCAMACHO | Approved | |
| 10/22/2018 | ELECTRIC - ABOVE CEILING | RCAMACHO | Approved | |
| 10/23/2018 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER CHLORINATION REPORT COMPLETED. PENDING ALL REVISIONS TO BUILDING |
| 10/24/2018 | FIRE - FINAL | JPEELDAVIS | Approved | OK to obtain a TCO |
| 10/26/2018 | ENGINEERING - FINAL | RLEDON | Approved | PER PHONE OK FOT TCO |
| 04/03/2019 | ELECTRIC - SERVICE UPGRADE | RCAMACHO | Approved |