Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM00016
Permit Details
Apply Date:
01/02/2007
Applicant:
WLB GROUP/ED ROLL
Description:
NEW DEALERSHIP:DESERT TOYOTA
Contractors:
- JOHNSON CARLIER INC
Permit Reviews
Permit Number - T07CM00016
Permit Status: C of o
Permit Description: NEW DEALERSHIP:DESERT TOYOTA
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/02/2007 | PLANS OK TO SUBMIT - SITE | 01/02/2007 | COMPLETED |
| 01/02/2007 | SITE | 01/29/2007 | COMPLETED |
| 01/02/2009 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 01/13/2009 | COMPLETED |
| 01/09/2009 | REVISION - SITE | 01/09/2009 | COMPLETED |
| 01/20/2009 | 3RD PARTY REVIEW-REVISION/OTHER | 01/20/2009 | COMPLETED |
| 02/20/2009 | REVISION - - 7TH | 02/20/2009 | COMPLETED |
| 03/12/2008 | REVISION - SITE | 03/12/2008 | COMPLETED |
| 03/19/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 05/16/2008 | COMPLETED |
| 03/27/2008 | RESUBMITTAL | 04/17/2008 | COMPLETED |
| 03/28/2008 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 04/09/2008 | COMPLETED |
| 04/09/2008 | POST 3RD PARTY REVIEW | 04/23/2008 | COMPLETED |
| 04/11/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 04/11/2007 | COMPLETED |
| 04/11/2007 | RESUBMITTAL - SITE ALL | 05/16/2007 | COMPLETED |
| 04/11/2007 | 3RD PARTY REVIEW-COMMERCIAL | 06/18/2007 | COMPLETED |
| 05/19/2008 | REVISION - - 1ST | 05/23/2008 | COMPLETED |
| 06/12/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 06/18/2008 | COMPLETED |
| 06/18/2007 | POST 3RD PARTY REVIEW | 07/31/2007 | COMPLETED |
| 06/22/2007 | RESUBMITTAL - SITE ALL | 07/31/2007 | COMPLETED |
| 06/25/2008 | REVISION - SITE | 07/14/2008 | COMPLETED |
| 06/30/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 06/30/2008 | COMPLETED |
| 08/14/2007 | RESUBMITTAL | 08/21/2007 | COMPLETED |
| 08/21/2007 | RESUBMITTAL | 08/27/2007 | COMPLETED |
| 09/05/2007 | RESUBMITTAL | 09/05/2007 | COMPLETED |
| 09/11/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 09/24/2008 | COMPLETED |
| 10/17/2007 | RESUBMITTAL - SITE | 11/01/2007 | COMPLETED |
| 10/23/2008 | REVISION - SITE | 10/23/2008 | COMPLETED |
| 12/04/2007 | RESUBMITTAL | 03/27/2008 | COMPLETED |
| 12/15/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 01/08/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM00016
Permit Status: C of o
Permit Description: NEW DEALERSHIP:DESERT TOYOTA
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/02/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM00016
Permit Description: NEW DEALERSHIP:DESERT TOYOTA
Total Completed Inspections - 55
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2007 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* |
| 10/26/2007 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* |
| 10/26/2007 | ELECTRIC - TEMPORARY POLE | RHOLLAND | Approved | IVRS - Inspection :* 1) INSTALL BREAKER LISTED BY MANUFACTURER |
| 10/29/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER |
| 11/27/2007 | FIRE - LANE SIGNS | CSCHULTZ | Approved | JUST WANTED INFO ON FD KEY BOXES |
| 11/30/2007 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* REINFORCEMENT STEEL @ GRID LINE 9/GD TO L & L/8.5 TO 10 |
| 12/07/2007 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* 1. OK 4 - 1" PVC FROM STUB UP TO GO TO 2ND FLOOR TO FRONT OF BUILDING 2. OK 4/0 UFER GROUND 3. OK 2 - 2 1/2" PVC FROM COLUMN LINE GD HEADING NORTH 60' 4. OK 1 - 2 1/2" PVC FROM EXTERIOR WEST WALL HEADING EAST 60' |
| 12/14/2007 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* COLUMN LINE 9 IN WALL DWV & WATER OK (2) HOSE BIBS EAST SERVICE BAY |
| 12/20/2007 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* AT STAIR #1 & #2 ONLY |
| 12/26/2007 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* 1) STEM WALL (2) REINFORCEMENT STEEL AT BLDG NORTH PORTALS-OK |
| 12/27/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* 1) CMU REINFORCEMENT STEEL AT GRID 8/A TO K FROM 25'-4" TO 29'-4" AND 10/A TO L FROM 4' TO 8' |
| 12/27/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* 1) OK 12-2 1/2" PVC CONTINUATION TO 2ND FLOOR STUB UP AREA UNDER SLAB 2) OK 6-1" PVC AT FRONT OF STORE FOR SIGN |
| 12/28/2007 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* (4) 8" RAIN DRAINS TESTED FROM 2" BLD. EXTERIOR TO 10' AFF COLUMN LINE 10 OK |
| 02/13/2008 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* TO BE INSPECTED ON PERMIT #T08PL00108 |
| 06/05/2008 | ELECTRIC - TEMP POWER FOR TEST | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/18/2008 | FIREWALL/FIREBARRIER/FIRESTOP | LHANLY | Approved | IVRS - Inspection :* 1. CONCRETE APPLICATION FOR FLOOR CUTS OK IN COMPUTER/PHONE ROOM. RECALL WHEN FIRESTOP IS COMPLETE. YOU MUST FIRESTOP CONDUIT OPENINGS. 2. 3HR WALL COMPLETE EXCEPT CAMERA WIRING SLEEVE IN 2ND FLOOR STORAGE |
| 06/20/2008 | ENGINEERING - FINAL | NKALAHAR | Approved | AS OF 12:00 TODAY -PAVERS NOT COMPLETE AT N SIDE OF SHOWROOM/OFFICES -DRIVEWAY NOT YET CURED -STRIPING NOT COMPLETE -FENCING NOT IN PLACE TO SEPARATE CONSTRUCTION FROM PUBLIC ACCESS -TRACK OUT ONTO 22ND ST ??-COBBLESTONE PAVERS ADA COMPLIANT ??-70% CONTRAST ON TRUNCATED DOMES |
| 06/23/2008 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
| 10/20/2008 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* CHECKED SEALED JOINTS ON DUCT WORK OK TO INSULATE |
| 10/24/2008 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* EXTERIOR PARKING GARAGE NORTH CANOPY & COLUMNS |
| 10/31/2008 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* USED CAR SALES AREA |
| 10/31/2008 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 11/05/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* BALANCE OF INTERIOR METAL STUD FRAMING @ USED CAR SALES AREA |
| 11/13/2008 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK RESTROOM AND JANITOR CLOSET |
| 11/18/2008 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* METAL ROOF DECK @ CARWASH |
| 11/18/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* 1. OK U.G AT CARWASH 2. OK PONY WALLS @ USED CAR SALES 3. OK HARD LIDS RESTROOMS @ USED CAR SALES |
| 11/20/2008 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* RESTROOM CORRIDOR, ALCOVE, PARKING ALCOVE, ROOMS #302 THRU #308 AND DRYWALL FACE AT DOOR TO STAIR #3 IN USED CAR SALES AREA |
| 12/05/2008 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* FAN COILS NOT PROPERLY FUSED WILL CHECK ON FINAL OK FOR CEILING TILES |
| 12/10/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* TESTED DUCT SMOKE DETECTORS NEED TO TEST CO2 SENSORS NEED AIR BALANCE REPORT |
| 12/11/2008 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - BACK WATER VALVE | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - ROOF DRAINS | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* |
| 12/11/2008 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 12/11/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 12/15/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* 1. OK FINAL CAR WASH 2. OK RELOCATION OF SPRINKLER PIPE 3. OK EXITS 4TH FLOOR OF PARKING GARAGE |
| 12/15/2008 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 12/17/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* 1. PROVIDE ACCESS TO VALVE & TRAP PRIMER IN WOMENS RESTROOM 2. PROVIDE CLEANOUT PLUG IN NEW LAUNDRY STACK 3. COMPLETE NOTES #4, #5 AND #6 RECEIVED BACTERIA REPORT FOR POTABLE WATER AND BACKFLOW CERTIFICATIONS |
| 12/18/2008 | FIRE - HYDRANTS | LTHOMAS | Approved | |
| 12/19/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* OFFICES @ 1ST FLOOR PARKING GARAGE N/W CORNER OK TO APPLY FOR TCO |
| 12/23/2008 | ELECTRIC - PROGRESS | RJIROUDE | Approved | IVRS - Inspection :* CANCELED BY CONTRACTOR |
| 03/10/2009 | OUTDOOR LIGHTING FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 03/10/2009 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* |
| 03/10/2009 | ELECTRIC - CONSTRUCTION POWER | RJIROUDE | Approved | IVRS - Inspection :* |
| 03/16/2009 | NPPO - FINAL | ACONNOR | Approved | |
| 03/16/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 03/25/2009 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
| 03/25/2009 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
| 03/27/2009 | FIRE - FINAL | LTHOMAS | Approved | |
| 04/01/2009 | PERMIT FINALED | LJACKSON | Approved |