Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Apply Date:
01/12/2006
Applicant:
N/A
Description:
4 PLEX:NEW
Contractors:
  • CATALINA CUSTOM CONSTRUCTION

Permit Reviews

Permit Number - T06CM00236
Permit Status: C of o
Permit Description: 4 PLEX:NEW
Start Date Submittal Complete Date Status  
03/28/2006 PLANS OK TO SUBMIT - RES 3RD PARTY 04/03/2006 COMPLETED Review Details
03/30/2006 PLANS OK TO SUBMIT - SITE 03/30/2006 COMPLETED Review Details
03/30/2006 SITE 05/30/2006 COMPLETED Review Details
04/03/2006 3RD PARTY REVIEW-RESIDENTIAL 06/07/2006 COMPLETED Review Details
06/07/2006 POST 3RD PARTY REVIEW 07/20/2006 COMPLETED Review Details
06/13/2006 RESUBMITTAL - SITE ALL 07/20/2006 COMPLETED Review Details
07/10/2006 OTHER 07/25/2006 COMPLETED Review Details
11/03/2006 3RD PARTY REVIEW-REVISION/OTHER 11/13/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM00236
Permit Status: C of o
Permit Description: 4 PLEX:NEW
Total Outstanding Activity Conditions - 1
Date Name
01/12/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM00236
Permit Description: 4 PLEX:NEW
Total Completed Inspections - 35
Date Description Inspector Results Comments
09/15/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1. ABS DWV UNDERGROUND FOR UNITS #A, #B, #C
OK TO COVER
WATER TEST ONE RISER TO TEN FEET
09/25/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
4 - #4 WHIPS TO COMMON REBAR, 4 - CLAMPS
11/02/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
11/02/2006 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
11/15/2006 ROOF NAILING GDABBS Approved IVRS - Inspection :*
PER PLANS
11/15/2006 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
PER PLANS
04/16/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
OK FOR SHEETROCK
04/27/2007 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved
04/27/2007 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
04/27/2007 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
05/14/2007 FRAMING GDABBS Approved IVRS - Inspection :*
VIEWED APT. #4'S NORTHSIDE ROOF
05/22/2007 STUCCO MESH JBURGE Approved IVRS - Inspection :*
OK TO STUCCO
05/22/2007 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
05/22/2007 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
05/22/2007 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
05/22/2007 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
06/05/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
07/16/2007 ELECTRIC - TEMP POWER FOR TEST CCLEMENS Approved IVRS - Inspection :*
07/17/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR #2, 3 & 4 PER C. CLEMENS
08/02/2007 OUTDOOR LIGHTING FINAL CCLEMENS Approved IVRS - Inspection :*
08/02/2007 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved IVRS - Inspection :*
08/06/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
08/06/2007 MECHANICAL - HOODS JMILITEL Approved
08/06/2007 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
08/09/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
OK FINAL ALL UNITS
08/09/2007 ELECTRIC - CONSTRUCTION POWER RJIROUDE Approved IVRS - Inspection :*
08/10/2007 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
08/10/2007 FIRE - FINAL LTHOMAS Approved
08/10/2007 FIRE SPKLR - FINAL LTHOMAS Approved
08/16/2007 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
08/27/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
08/28/2007 PLUMBING - PRE SLAB RRICH Approved
09/06/2007 ENGINEERING - FINAL MRUSSO Approved
09/21/2007 PERMIT FINALED ACONNOR Approved
09/21/2007 LANDSCAPE - FINAL ACONNOR Approved

Documents

File Name Document Type  
C OF O_05-19-2009.TIF CERT OF OCC VIEW
TEMP C OF O_09-16-2007.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
0236-01-0001-01-REVISION001.TIF CONSTRPLANS VIEW
0236-01-0001-01-REVISION002.TIF CONSTRPLANS VIEW
0236-01-0001-01-REVISION003.TIF CONSTRPLANS VIEW
0236-01-0001-01-REVISION004.TIF CONSTRPLANS VIEW
0236-01-0001-01-REVISION005.TIF CONSTRPLANS VIEW
0236-01-0001-01-REVISION006.TIF CONSTRPLANS VIEW