Permit: T06CM00236

Parcel: 12214018A

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
04/16/2007 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
OK FOR SHEETROCK
04/11/2007 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
DO NOT RUN ANY FLEX DUCT IN OR THROUGH A FIRE PARTITION.
EXTEND DRYER VENT UP INTO T-TOP & REMOVE SCREEN.
REMOVE ALL CONDENSATE TRAPS THAT ARE FLATTENED
MUST BE MIN. 3/4" INTERNAL DIAMETER
03/07/2007 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE SCREEN FROM DRYER VENT T-TOP.
DRYER VENT INSTALLED IN WRONG ROOM.
PROVIDE PLATE STRAPS.
2. SCREW EXHAUST DUCTS TO FAN OUTLETS.
3. INSTALL FAN COIL.
4. PROVIDE MIN. 1/8" PER FT. SLOPE ON CONDENSATE DRAIN.
5. DO NOT PENETRATE A FIREWALL WITH FLEX DUCT.
6. SECURE ALL DRYER VENTS. UNIT 2 DRYER VENT JOINT NEEDS TAPE.
7. USE ONLY 2" MIN. R-5 DUCT WRAP ON PLENUMS.
8. UNIT 3 EXTEND DRYER VENT UP INTO T-TOP
9. 2ND FLOOR UNIT INSULATE ALL SIDE WALL REGISTER BOXES. TERMINATE EXHAUST DUCT THRU THE ROOF.
10. PROVIDE PLATE STRAPS 2ND FLOOR REFER LINE SET.