Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
| 04/11/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DO NOT RUN ANY FLEX DUCT IN OR THROUGH A FIRE PARTITION. EXTEND DRYER VENT UP INTO T-TOP & REMOVE SCREEN. REMOVE ALL CONDENSATE TRAPS THAT ARE FLATTENED MUST BE MIN. 3/4" INTERNAL DIAMETER |
|
| 03/07/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE SCREEN FROM DRYER VENT T-TOP. DRYER VENT INSTALLED IN WRONG ROOM. PROVIDE PLATE STRAPS. 2. SCREW EXHAUST DUCTS TO FAN OUTLETS. 3. INSTALL FAN COIL. 4. PROVIDE MIN. 1/8" PER FT. SLOPE ON CONDENSATE DRAIN. 5. DO NOT PENETRATE A FIREWALL WITH FLEX DUCT. 6. SECURE ALL DRYER VENTS. UNIT 2 DRYER VENT JOINT NEEDS TAPE. 7. USE ONLY 2" MIN. R-5 DUCT WRAP ON PLENUMS. 8. UNIT 3 EXTEND DRYER VENT UP INTO T-TOP 9. 2ND FLOOR UNIT INSULATE ALL SIDE WALL REGISTER BOXES. TERMINATE EXHAUST DUCT THRU THE ROOF. 10. PROVIDE PLATE STRAPS 2ND FLOOR REFER LINE SET. |