Permit: T06CM00236

Parcel: 12214018A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/27/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
08/17/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
NO HORIZONTAL PVC AT IRRIGATION. USE COPPER
UNION STILL DRIPPING AT FP
TEF TAPE ON ALL C O S
08/06/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- DRIP ON RD UNIONS
- IRRIGATION ASSEMBLY NOT INSTALLED
- SERVICE VALVE
- EXTERIOR CLEANOUTS
- NO PLUMBING PROBLEMS FOR TCO
07/25/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- USE THREAD SEALANT ON ALL CO PLUGS
- USE CAST IRON COVER IN ASPHALT
- USE FRANK PATTERN COVERS IN CONCRETE
- ON WALL CLEANOUT USE PLUGS LISTED TO RECEIVE SCREW FROM COVER.
- HAMMER ARRESTORS REQUIRED 609.10
- SLOPE KS DRAINS
- SUPPORT EXP. TANKS
- FOR FUTURE SANITARY TEES ARE ALLOWED ON VERTICAL PIPING ONLY