Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
149 N STONE AV
Address NEW:
149 N STONE AV
Apply Date:
10/31/2005
Applicant:
MICKELBERG, PAUL DAVID
Description:
TI:DOT OFFICE 1ST & 2ND FLOOR ONLY
Architects:
  • MICKELBERG, PAUL DAVID
Contractors:
  • TRIUMPH BUILDERS SOUTHWEST LLC *C*

Permit Reviews

Permit Number - T05CM05519
Permit Status: C of o
Permit Description: TI:DOT OFFICE 1ST & 2ND FLOOR ONLY
Start Date Submittal Complete Date Status  
01/25/2006 POST 3RD PARTY REVIEW 03/17/2006 COMPLETED Review Details
01/29/2007 3RD PARTY REVIEW-REVISION/OTHER 01/29/2007 COMPLETED Review Details
02/12/2008 REVISION - - 1ST 03/21/2008 COMPLETED Review Details
03/17/2006 POST 3RD PARTY REVIEW 08/17/2006 COMPLETED Review Details
03/21/2008 OTHER 10/21/2008 COMPLETED Review Details
10/01/2007 3RD PARTY REVIEW-REVISION/OTHER 11/06/2007 COMPLETED Review Details
10/31/2005 PLANS OK TO SUBMIT - 3RD PARTY 10/31/2005 COMPLETED Review Details
10/31/2005 3RD PARTY REVIEW-COMMERCIAL TI 01/25/2006 COMPLETED Review Details
11/28/2007 POST 3RD PARTY REVIEW 12/19/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05519
Permit Status: C of o
Permit Description: TI:DOT OFFICE 1ST & 2ND FLOOR ONLY
Total Outstanding Activity Conditions - 1
Date Name
10/31/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM05519
Permit Description: TI:DOT OFFICE 1ST & 2ND FLOOR ONLY
Total Completed Inspections - 40
Date Description Inspector Results Comments
10/17/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
RESTROOMS #116 & #119
OK FOR CONCRETE
10/30/2006 BUILDING PRE-SLAB AALEGRIA Approved IVRS - Inspection :*
IN COMPLIANCE WITH APPROVED PLANS AND SPEC. DETAIL ON S3.1 DETAIL 103
11/30/2006 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
12/07/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
HOT WATER PIPING 100 PSI TEST
2ND, 3RD, 4TH FLOOR OK TO INSULATE
12/07/2006 FRAMING LHANLY Approved IVRS - Inspection :*
1. OK TO 1 SIDE ALL CFS FRAMING.
2. PROVIDE SLIP JOINT AT HEAD OF WALLS PER DISCUSSION/PLAN REQUIREMENTS.
3. MID-SPAN BRIDGING REQUIRED.
12/10/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1. CALL 03050 FOR GAS INSPECTION
2. ROOF DRAINS TERMINATING AT LOBBY 100 OK
3. 4" ROOF DRAINS CONNECTING TO EXISTING AND RUN OUT THE FRONT OK
4. SINGLE 3" ROOF DRAIN OK
5. RESTROOMS #116 & #119 OK TO COVER WALLS ONLY
6. PIPING DEMO'D IN BASEMENT OK TO COVER
7. OK TO COVER JANITOR ROOM 206
12/11/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
1. REQUIRE ENGINEERS APPROVAL OF YARDWATER REDLINES
2. GAS PENETRATION THRU ROOF REQUIRES FLASHING
3. CHECK ROOFTOP SIZING
12/11/2006 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
12/29/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
ONE SIDE ONLY
12/29/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
1) MAKE SURE BOXES ARE PROPERLY MOUNTED-NEC 314.23 B1
2) MAKE SURE EMT PROPERLY SECURED/SUPPORTED-NEC 358.30 AND MAXIMUM 360 DEGREE IN BENDS NEC 358.26
3) PULL BOX SIZE INFORMATION-NEC 314.28
4) GUTTER CONDUCTOR DERATION INFORMATION-NEC 366.6/366.7
5) OK RESTROOM COVER 2ND THRU 4TH FLOORS
03/12/2007 TEP CLEARANCE - AM BFLORES Approved TMPP PER R.MAJUTA
05/10/2007 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
05/10/2007 STUCCO MESH LHANLY Approved IVRS - Inspection :*
05/10/2007 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
05/10/2007 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection :*
05/22/2007 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
05/22/2007 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
05/22/2007 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
05/22/2007 ELECTRIC - SERVICE UPGRADE RMAJUTA Approved IVRS - Inspection :*
05/22/2007 ELECTRIC - TEMP POWER FOR TEST RMAJUTA Approved IVRS - Inspection :*
05/22/2007 ELECTRIC - CONSTRUCTION POWER RMAJUTA Approved IVRS - Inspection :*
05/22/2007 ELECTRIC - TEMPORARY SERVICE RMAJUTA Approved IVRS - Inspection :*
05/22/2007 ELECTRIC - CABLE DROP RMAJUTA Approved IVRS - Inspection :*
06/05/2007 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
06/05/2007 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
06/05/2007 FIRE SPKLR - FINAL LTHOMAS Approved
06/05/2007 FIRE - FINAL LTHOMAS Approved
06/05/2007 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/06/2007 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
INTERIOR OK
1. OK OUTSIDE LIGHTING STONE SIDE
2. LIGHTING IN FRONT OF POCA COSA NOT IN
3. LIGHTING IN FRONT ALAMEDA SIDE NOT IN
06/07/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
06/29/2007 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
1. CONNECT SUMP PUMP DIRECTLY INTO DISCONNECT
REMOVE WIRING TO OLD BELL
2. REMOVE OLD WIRING TO CONDUITS ABOVE OLD SW GEAR AREA.
06/29/2007 OUTDOOR LIGHTING FINAL RMAJUTA Approved IVRS - Inspection :*
07/02/2007 ELECTRIC - UNDERGROUND RMAJUTA Approved
07/03/2007 NPPO - FINAL ACONNOR Approved N/A
07/09/2007 SIGN - FINAL JYBARRA Approved PERMIT OBTAINED
07/11/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
12/27/2007 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
12/28/2007 ENGINEERING - FINAL MRUSSO Approved
12/31/2007 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
WHERE ARE YOUR ORIGINAL RED LINE DRAWINGS AS DRAWN BY GARY THOMPSON. THESE ORIGINAL RED LINES ARE ESSENTIAL TO DETERMINING THE EXTENT OF CHANGED WORK
CONTRACTOR TO PAY REINSPECTION FEE
03/21/2008 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
T05CM05519_001.TIF CONSTRPLANS VIEW
T05CM05519_002.TIF CONSTRPLANS VIEW
T05CM05519_003.TIF CONSTRPLANS VIEW
T05CM05519_004.TIF CONSTRPLANS VIEW
T05CM05519_005.TIF CONSTRPLANS VIEW
T05CM05519_006.TIF CONSTRPLANS VIEW
T05CM05519_007.TIF CONSTRPLANS VIEW
T05CM05519_008.TIF CONSTRPLANS VIEW
T05CM05519_009.TIF CONSTRPLANS VIEW
T05CM05519_010.TIF CONSTRPLANS VIEW
T05CM05519_011.TIF CONSTRPLANS VIEW
T05CM05519_012.TIF CONSTRPLANS VIEW
T05CM05519_013.TIF CONSTRPLANS VIEW
T05CM05519_014.TIF CONSTRPLANS VIEW
T05CM05519_015.TIF CONSTRPLANS VIEW
T05CM05519_016.TIF CONSTRPLANS VIEW
T05CM05519_017.TIF CONSTRPLANS VIEW
T05CM05519_018.TIF CONSTRPLANS VIEW
T05CM05519_019.TIF CONSTRPLANS VIEW
T05CM05519_020.TIF CONSTRPLANS VIEW
T05CM05519_021.TIF CONSTRPLANS VIEW
T05CM05519_022.TIF CONSTRPLANS VIEW
T05CM05519_023.TIF CONSTRPLANS VIEW
T05CM05519_024.TIF CONSTRPLANS VIEW
T05CM05519_025.TIF CONSTRPLANS VIEW
T05CM05519_026.TIF CONSTRPLANS VIEW
T05CM05519_027.TIF CONSTRPLANS VIEW
T05CM05519_028.TIF CONSTRPLANS VIEW
T05CM05519_029.TIF CONSTRPLANS VIEW
T05CM05519_030.TIF CONSTRPLANS VIEW
T05CM05519_031.TIF CONSTRPLANS VIEW
T05CM05519_032.TIF CONSTRPLANS VIEW
T05CM05519_033.TIF CONSTRPLANS VIEW
T05CM05519_034.TIF CONSTRPLANS VIEW
T05CM05519_035.TIF CONSTRPLANS VIEW
T05CM05519_036.TIF CONSTRPLANS VIEW
T05CM05519_037.TIF CONSTRPLANS VIEW
T05CM05519_038.TIF CONSTRPLANS VIEW
T05CM05519_039.TIF CONSTRPLANS VIEW
T05CM05519_040.TIF CONSTRPLANS VIEW
T05CM05519_041.TIF CONSTRPLANS VIEW
T05CM05519_042.TIF CONSTRPLANS VIEW
T05CM05519_043.TIF CONSTRPLANS VIEW
T05CM05519_044.TIF CONSTRPLANS VIEW
T05CM05519_045.TIF CONSTRPLANS VIEW
T05CM05519_046.TIF CONSTRPLANS VIEW
T05CM05519_047.TIF CONSTRPLANS VIEW
T05CM05519_048.TIF CONSTRPLANS VIEW
T05CM05519_049.TIF CONSTRPLANS VIEW
T05CM05519_050.TIF CONSTRPLANS VIEW
T05CM05519_051.TIF CONSTRPLANS VIEW
T05CM05519_052.TIF CONSTRPLANS VIEW
T05CM05519_053.TIF CONSTRPLANS VIEW
T05CM05519_054.TIF CONSTRPLANS VIEW
T05CM05519_055.TIF CONSTRPLANS VIEW
T05CM05519_056.TIF CONSTRPLANS VIEW
T05CM05519_057.TIF CONSTRPLANS VIEW
T05CM05519_058.TIF CONSTRPLANS VIEW
T05CM05519_059.TIF CONSTRPLANS VIEW
T05CM05519_060.TIF CONSTRPLANS VIEW
T05CM05519_061.TIF CONSTRPLANS VIEW
T05CM05519_062.TIF CONSTRPLANS VIEW
T05CM05519_063.TIF CONSTRPLANS VIEW
T05CM05519_064.TIF CONSTRPLANS VIEW
T05CM05519_065.TIF CONSTRPLANS VIEW
T05CM05519_066.TIF CONSTRPLANS VIEW
T05CM05519_067.TIF CONSTRPLANS VIEW
T05CM05519_068.TIF CONSTRPLANS VIEW
T05CM05519_069.TIF CONSTRPLANS VIEW
T05CM05519_070.TIF CONSTRPLANS VIEW
T05CM05519_071.TIF CONSTRPLANS VIEW
T05CM05519_072.TIF CONSTRPLANS VIEW
T05CM05519_073.TIF CONSTRPLANS VIEW
T05CM05519_074.TIF CONSTRPLANS VIEW
T05CM05519_075.TIF CONSTRPLANS VIEW
T05CM05519_076.TIF CONSTRPLANS VIEW
T05CM05519_077.TIF CONSTRPLANS VIEW
T05CM05519_078.TIF CONSTRPLANS VIEW
T05CM05519_079.TIF CONSTRPLANS VIEW
T05CM05519_080.TIF CONSTRPLANS VIEW
T05CM05519_081.TIF CONSTRPLANS VIEW
T05CM05519_082.TIF CONSTRPLANS VIEW
T05CM05519_083.TIF CONSTRPLANS VIEW
T05CM05519_084.TIF CONSTRPLANS VIEW
T05CM05519_085.TIF CONSTRPLANS VIEW
T05CM05519_086.TIF CONSTRPLANS VIEW
T05CM05519_087.TIF CONSTRPLANS VIEW
T05CM05519_088.TIF CONSTRPLANS VIEW
T05CM05519_089.TIF CONSTRPLANS VIEW
T05CM05519_090.TIF CONSTRPLANS VIEW
T05CM05519_091.TIF CONSTRPLANS VIEW
T05CM05519_092.TIF CONSTRPLANS VIEW
T05CM05519_093.TIF CONSTRPLANS VIEW
T05CM05519_094.TIF CONSTRPLANS VIEW
T05CM05519_095.TIF CONSTRPLANS VIEW
T05CM05519_096.TIF CONSTRPLANS VIEW
T05CM05519_097.TIF CONSTRPLANS VIEW
T05CM05519_098.TIF CONSTRPLANS VIEW
T05CM05519_099.TIF CONSTRPLANS VIEW
T05CM05519_100.TIF CONSTRPLANS VIEW
T05CM05519_101.TIF CONSTRPLANS VIEW
T05CM05519_102.TIF CONSTRPLANS VIEW
T05CM05519_103.TIF CONSTRPLANS VIEW
T05CM05519_104.TIF CONSTRPLANS VIEW
T05CM05519_105.TIF CONSTRPLANS VIEW
T05CM05519_106.TIF CONSTRPLANS VIEW
T05CM05519_107.TIF CONSTRPLANS VIEW
T05CM05519-R2_001.TIF CONSTRPLANS VIEW
T05CM05519-R_001.TIF CONSTRPLANS VIEW
T05CM05519-R_002.TIF CONSTRPLANS VIEW
T05CM05519-R_003.TIF CONSTRPLANS VIEW
T05CM05519-R_004.TIF CONSTRPLANS VIEW
T05CM05519-R_005.TIF CONSTRPLANS VIEW
T05CM05519-R_006.TIF CONSTRPLANS VIEW
T05CM05519-R_007.TIF CONSTRPLANS VIEW
T05CM05519-R_008.TIF CONSTRPLANS VIEW
T05CM05519-R_009.TIF CONSTRPLANS VIEW
T05CM05519-R_010.TIF CONSTRPLANS VIEW
STRUCCALCS.TIF DOCUMENTS VIEW
TECHSPECS_01.TIF DOCUMENTS VIEW
TECHSPECS_02.TIF DOCUMENTS VIEW
TECHSPECS_03.TIF DOCUMENTS VIEW
TECHSPECS_04.TIF DOCUMENTS VIEW
TECHSPECS_05.TIF DOCUMENTS VIEW
TECHSPECS_06.TIF DOCUMENTS VIEW
TECHSPECS_07.TIF DOCUMENTS VIEW
TECHSPECS_08.TIF DOCUMENTS VIEW
TECHSPECS_09.TIF DOCUMENTS VIEW
TECHSPECS_10.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
C OF O_03-21-2008.TIF CERT OF OCC VIEW
TEMP C OF O_08-10-2007.TIF CERT OF OCC VIEW