Permit Details

Status:
Si_xpire
Type:
COMMERCIAL OTHER
Address NEW:
1401 S SAN ANTONIO DR
Apply Date:
07/29/2003
Applicant:
N/A
Description:
GRADING:55,708 CY CUT/48,289 CY FILL
Contractors:
  • DESERT EARTH CONTRACTING L L C

Permit Reviews

Permit Number - T03BU01937
Permit Status: Si_xpire
Permit Description: GRADING:55,708 CY CUT/48,289 CY FILL
Start Date Submittal Complete Date Status  
02/11/2009 REVISION - GRADING 03/11/2009 COMPLETED Review Details
03/11/2009 REVISION - GRADING 03/31/2009 COMPLETED Review Details
05/13/2004 RESUBMITTAL - GRADING ALL 06/16/2004 COMPLETED Review Details
07/13/2004 RESUBMITTAL - GRADING 10/27/2004 COMPLETED Review Details
07/29/2003 PLANS OK TO SUBMIT - GRADING 07/29/2003 COMPLETED Review Details
07/30/2003 GRADING 09/03/2003 COMPLETED Review Details
08/12/2009 REVISION - GRADING 09/25/2009 COMPLETED Review Details
10/26/2009 RESUBMITTAL - GRADING 10/26/2009 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T03BU01937
Permit Status: Si_xpire
Permit Description: GRADING:55,708 CY CUT/48,289 CY FILL
Total Outstanding Activity Conditions - 5
Date Name
07/29/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/23/2004 VACATION OF EAST BRITTANIA DRIVE MUST BE COMPLETED PRIOR TO FINAL GRADING INSPECTION APPROVAL.
07/23/2004 SPECIAL INSPECTION REQUIRED. GEOTECHNICAL STATEMENT IS REQUIRED TO BE SUBMITTED STATING THAT THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER HAS BEEN FOLLOWED FOR EARTHWORK NEAR LOTS 56 -62 AND 112-114. SEE GEOTECHNICAL SUBSURFACE EVALUATION PREPARED BY GRC CONSULTANTS, INC. (DATED 12-15-03).
03/23/2009 The following 3 conditions apply to grading permit T03BU01937- R: 1) Prior to project close-out, the project will still require a proposed solution to the erosion issues at the top of slope north of Woodsville Drive. 2) Any remaining improvements or remediation required for the SCZ area shall be completed to the satisfaction of DSD Landscaping. 3) Special Inspection required. Geotechnical Statement is required to be submitted stating that the recommendations of the Geotechnical Engineer has been followed for earthwork near lots 56-62 and 112 and 114, See Geotechnical Subsurface Evaluation prepared by GRC Consultants Inc (Dated 12-15-03).
03/25/2009 LANDSCAPE INSPECTION REQUIRED BEFORE FINAL INSPECTION.

Completed Inspections

Permit Status: Si_xpire
Permit Number: T03BU01937
Permit Description: GRADING:55,708 CY CUT/48,289 CY FILL
Total Completed Inspections - 7
Date Description Inspector Results Comments
10/01/2004 ENGINEERING PRE-CONSTRUCTION JSALINE Approved NO ACTIVITY AT THIS TIME. RESCHEDULED FOR THE END OF THE MONTH.
11/01/2004 NPPO PRE PERMIT INSPECTION ACONNOR Approved
11/22/2004 STORMWATER INSTALL OF CONTROLS JSALINE Approved RESCHEDULED FOR 24TH.
11/07/2006 GRADING - FINAL MAVERY Approved Met with Elizabeth and TDOT in regards to sidewalk around perimeter of project. TDOT wants a 5 foot sidewalk with a 2 to 3 foot utility strip between sidewalk and curb. Placement may very so utility poles and bus stop don't interfere.
12/22/2006 STORMWATER FOLLOW-UP INSP MAVERY Approved Contractor needs to:
1- Clean material off HC ramps, westside of project.
2- Clean wash out next to 1309 Woodbine Ln.
Spoke to Ron with KB Homes in regards to issues, also the need to stabilize all areas distrubed by construction.
11/20/2008 LANDSCAPE INSPECTION ACONNOR Approved According to the approved tentative plat Case# S02-046 the 30 feet wide buffer, adjacent to the MS&R right-of-way line, is to be preserved and maintained in its natural state. The buffer area shall be in lieu of the landscape border required along street frontages under LUC 3.7.0, Landscaping and Screening Regulations. No development may occur in a Scenic Route buffer area except as provided in Sec. 3.7.5.2.C. Decomposed granite or Decorative rock can not be located within scenic buffer along Mission Rd.
08/13/2009 GRADING - TIER REV ELEIBOLD Approved A COPY OF THE FINAL REVISED AS-BUILT GRADING PLANS SUBMITTED 12AUG09 ARE BEING FORWARDED TO INSPECTIONS. DIRTGUY SAYS CLOSURE LETTERS WILL BE SUBMITTED AFTER FINAL ENGR INSPECTION IS APPROVED.

Documents

File Name Document Type  
ASBUILT_1.TIF GRADING PLANS VIEW
ASBUILT_2.TIF GRADING PLANS VIEW
ASBUILT_3.TIF GRADING PLANS VIEW
ASBUILT_5.TIF GRADING PLANS VIEW
ASBUILT_6.TIF GRADING PLANS VIEW
ASBUILT_7.TIF GRADING PLANS VIEW
ASBUILT_8.TIF GRADING PLANS VIEW
ASBUILT_9.TIF GRADING PLANS VIEW
None DOCUMENTS VIEW