Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-1023-02505
Permit Details
Apply Date:
10/23/2023
Applicant:
Patric Spydell
Description:
This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Permit Reviews
Permit Number - TC-COM-1023-02505
Permit Status: Issued
Permit Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/30/2023 | COMMERCIAL REVIEW - FULL v.1 | 11/30/2023 | REQUIRES RESUBMIT |
12/22/2023 | COMMERCIAL REVIEW - FULL v.2 | 01/23/2024 | REQUIRES RESUBMIT |
07/16/2024 | COMMERCIAL REVIEW - FULL v.1 | 08/16/2024 | REQUIRES RESUBMIT |
08/29/2024 | COMMERCIAL REVIEW - FULL v.2 | 10/02/2024 | APPROVED |
10/10/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/11/2024 | APPROVED |
05/15/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/22/2024 | APPROVED |
03/04/2024 | RESTAMP - COMMERCIAL v.1 | 03/05/2024 | APPROVED |
10/02/2024 | RESTAMP - COMMERCIAL v.1 | 10/02/2024 | APPROVED |
12/12/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/18/2024 | APPROVED |
01/25/2024 | COMMERCIAL REVIEW - FULL v.3 | 03/04/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-1023-02505
Permit Status: Issued
Permit Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Total Outstanding Activity Conditions - 10
Date | Name |
---|---|
01/30/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
01/30/2024 | Masonry Inspection Report submittal review is required. |
01/30/2024 | SPECIAL INSPECTION FOR MEDICAL GASES IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
01/30/2024 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |
Conditions
Permit Number - TC-COM-1023-02505
Permit Status: Issued
Permit Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Date | Description | Comments |
---|---|---|
03/05/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
10/30/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
10/30/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
12/18/2024 | ||
05/22/2024 | Stair Designs must be submitted and approved prior to... |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-1023-02505
Permite Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Total Outstanding Inspections - 11
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/16/2024 | COT - FCON - Sprinkler - Final | N/A | Not Ready | customer did not understand inspection descriptions |
06/12/2024 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | East side to large elevator, and small elevator. |
07/30/2024 | COT - HCEL - Grounding/Bonding | N/A | Partial Pass | 7/30/24: ufer for northwest corner property okay to place concrete |
07/23/2024 | COT - HCPL - Plumbing Progress | N/A | Partial Pass | Main drain on South of building B. |
10/14/2024 | COT - LCPL - Yard Water Line | N/A | Canceled | |
10/14/2024 | COT - HCPL - Plumbing Intermediate | N/A | Not Ready | |
10/30/2024 | COT - HCBU - Preslab | N/A | Partial Pass | Level One, West half. |
12/04/2024 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | 12/3/2024 4th floor monoco fire proofing approved. Pending columns and beams at stairways. RFI on angle bracing for coverage. |
11/26/2024 | COT - HCBU - Exterior Clips/Sheathing | N/A | Partial Pass | Levels One through Four, North wall. |
12/05/2024 | COT - HCBU - Framing | N/A | Partial Pass | East end projection. |
09/24/2024 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | Main duct banks underslab |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-1023-02505
Permit Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/31/2024 | COT - HCEL - Electrical Progress | Passed | ||
09/13/2024 | COT - HCPL - Plumbing Progress | Passed | ||
09/24/2024 | COT - HCPL - Sewer | Passed | ||
09/24/2024 | COT - HCEL - Electrical Underground | Passed | ||
10/07/2024 | PDSD Heavy Commercial Building Division Pre-Construction Meeting | Passed | ||
11/04/2024 | COT - HCPL - Rough Soil | Passed | Balance of Level One. |
Scheduled Inspections
Scheduled Inspections - TC-COM-1023-02505
Status: Issued
Description: This for the construction of a new Group I-2 Institutional - Condition 2, Type I-B Construction, 4 Story In-Patient Rehabilitation Hospital at 355 N. Wilmot Road, Tucson. This will be for the Building Permit connected with the civil and rezoning of the site for Account No. TD-DEV-0623-00283 being currently reviewed.
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
12/23/2024 | COT - HCEL - Electrical Intermediate | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)