Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Apply Date:
01/15/2020
Applicant:
N/A
Description:
BENEDICTINE MONESTARY - BLDG 3
Contractors:
  • SUNDT CONSTRUCTION

Permit Reviews

Permit Number - T20CM00313
Permit Status: C of o
Permit Description: BENEDICTINE MONESTARY - BLDG 3
Start Date Submittal Complete Date Status  
01/15/2020 PLANS OK TO SUBMIT - COMM 01/23/2020 COMPLETED Review Details
01/27/2020 COMMERCIAL - NEW 04/07/2020 COMPLETED Review Details
02/16/2021 RESUBMITTAL 03/08/2021 COMPLETED Review Details
04/07/2020 RESUBMITTAL - TI ALL 04/13/2020 COMPLETED Review Details
04/13/2020 RESUBMITTAL 04/30/2020 COMPLETED Review Details
07/22/2020 REVISION - - 1ST 08/04/2020 COMPLETED Review Details
08/17/2020 REVISION - - 2ND 02/16/2021 COMPLETED Review Details
08/27/2021 REVISION - - 3RD 09/14/2021 COMPLETED Review Details
10/13/2021 RESUBMITTAL 10/26/2021 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T20CM00313
Permit Description: BENEDICTINE MONESTARY - BLDG 3
Total Completed Inspections - 45
Date Description Inspector Results Comments
11/10/2020 PLUMBING - GAS PRESSURE TEST ESTEVENS Approved Partial. East side of building 3 going south west approximately 70 feet.
12/02/2020 PLUMBING - ROUGH, SOIL ESTEVENS Approved Partial. Plumbing connection from existing building to new plumbing.
12/16/2020 EXCAVATION/LAYOUT REBAR & ZON ESTEVENS Approved Partial. Retaining wall for courtyard stairway.
12/17/2020 BUILDING PRE-SLAB ESTEVENS Approved Partial. Building 3. Level 3, Dolphins section.
07/27/2021 TEP CLEARANCE - PM ESTEVENS Approved CODE ECO/SES OW/OWNERS PANEL/BUILDING 3, NE ELECT ROOM.
08/19/2021 TEP CLEARANCE - AM JBURGE Approved CODE ECO/ Level #1; SES for Northwest apartments: Meters and disconnects: Owner’s meter northwest; Cafe 108.1; Restaurant 108.2; Cafe 109; Restaurant 110 (line side); Restaurant 110 (load side) meter 3M2.
Meters: Level #2: 3201; 3202; 3203; 3204; 3205; 3206; 3207; 3208; 3209; 3210; 3211; 3212; 3213; 3214; 3215; 3216; 3217.
Level #3: 3301; 3302; 3303; 3304; 3305; 3306; 3307; 3308; 3309; 3310; 3311; 3312; 313; 3314; 3315; 3316; 3317.
Level #4: 3401; 3402; 3403; 4304. Ok to energize disconnects and room meters.
10/28/2021 ENGINEERING - FINAL DROBERTS Approved OK FOR A TCO FOR OCCUPANCY BUT NOT FOR THE FINAL
10/28/2021 FIRE - ALARM FINAL MRoss Approved -Need to test NW elevator 2 way communication
-OS&Y valves need to be monitored.
10/28/2021 FIRE - FINAL MRoss Approved OK to obtain TCO from the building department for occupancy of the residential areas, the commercial area is not included and not approved.

-NW elevator 2 way communication still to be tested
-OS&Y valves on both pumps to be locked until they are monitored
-Install remaining signage in stairwells and exterior signs.
-Install "Combo" sign below FDC sign.
-Add multiple sets of key to knox boxes
10/28/2021 FIRE SPKLR - FINAL MRoss Approved -OS&Y valves need to be monitored
- locking FDC plugs required.
-Replace missing standpipe caps in stairwells.
10/29/2021 BUILDING - FINAL ESTEVENS Approved Partial. Ok for TCO
11/01/2021 REINFORCED MASONRY PRE-GROUT ESTEVENS Approved 1020, 1040, 1041, 1075, 2060, 2075, N/A
11/01/2021 STUCCO MESH ESTEVENS Approved 1020, 1040, 1041, 1075, 2060, 2075, N/A
11/01/2021 U VALUE FOR WINDOW ESTEVENS Approved
11/01/2021 BUILDING - PROGRESS ESTEVENS Approved 1020, 1040, 1041, 1075, 2060, 2075, N/A
11/01/2021 ELECTRIC - TEMPORARY SERVICE ESTEVENS Approved 1020, 1040, 1041, 1075, 2060, 2075, N/A
11/01/2021 ELECTRIC - PROGRESS ESTEVENS Approved 1020, 1040, 1041, 1075, 2060, 2075, N/A
11/01/2021 PLUMBING - ROOF DRAINS ESTEVENS Approved Approved. Inspected under 3035.
11/01/2021 MECHANICAL - HOODS ESTEVENS Approved Approved. Smoke test on duct only. Restaurant to be going in commercial space below.
11/01/2021 SHEET ROCK NAILING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - ABOVE CEILING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - BACK WATER VALVE ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 MECHANICAL - ABOVE CEILING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 STEM WALL/RETAINING WALL ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 FRAMING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 FIREWALL/FIREBARRIER/FIRESTOP ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 EXT METAL CLIPS/EXT SHEATHING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 BUILDING ABOVE CEILING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - UFER ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - UNDERGROUND ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - INTERMEDIATE ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - ABOVE CEILING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - CONSTRUCTION POWER ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - FINAL ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - INTERMEDIATE ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - YARD WTR LINE/TEST ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - SEWER HCS CONNECT ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 SITE - SEWER ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 PLUMBING - FINAL ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 MECHANICAL - INTERMEDIATE ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 MECHANICAL - FINAL ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 ELECTRIC - OUTDOOR LIGHTING ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/01/2021 OUTDOOR LIGHTING FINAL ESTEVENS Approved 1010, 3057,2005,3005,1015,3040, 1030, 1045, 2061, 1025, 3036, 4036, 3050, 1005, 2010, 1036, 2036, 2090, 3090, 4090, 2085, 2099. Approved.
11/02/2021 ROOF NAILING ESTEVENS Approved Approved
09/16/2022 CERTIFICATE OF OCCUPANCY JG3 Approved

Documents

File Name Document Type  
SPECIAL INSPECTION CERT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERT.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
STRUC CALCS.PDF DOCUMENTS VIEW
REVISION NARRATIVE.PDF DOCUMENTS VIEW
REV1_PLAN SET.PDF CONSTRPLANS VIEW
REV3_PLAN SET.PDF DOCUMENTS VIEW
TCO T20CM00313.PDF DOCUMENTS VIEW
PLAN SET CONSTRPLANS VIEW
ENVELOPE COMPLIANCE REPORT BLDG #3 SOUTH.PDF DOCUMENTS VIEW
DEFERRED SUBMITTAL - PREFABRICATED WOOD TRUSS SHOP DRAWINGS.PDF DOCUMENTS VIEW
GEOTECH.PDF DOCUMENTS VIEW
GEOTECH ADDENDUM NO.1.PDF DOCUMENTS VIEW
GEOTECH ADDENDUM NO. 2.PDF DOCUMENTS VIEW
HVAC LOAD CALCS.PDF DOCUMENTS VIEW
PROJECT MANUAL.PDF DOCUMENTS VIEW
PLUMBING FIXTURE CUTS.PDF DOCUMENTS VIEW
PLAN SET NORTH BUILDING L2 & L3 POST TENSIONS SHOP DRAWINGS_TLCP.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PT NORTH BUILDING LEVEL 4.PDF DOCUMENTS VIEW
STRUCTURAL CALCULATIONS.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERTIFICATES.PDF DOCUMENTS VIEW