Permit: T05CM02886
Permit Details
Apply Date:
06/21/2005
Applicant:
N/A
Description:
NEW CHURCH
Architects:
- CALL, BRUCE RUTTER
Contractors:
- OKLAND CONSTRUCTION COMPANY INC
Permit Reviews
Permit Number - T05CM02886
Permit Status: C of o
Permit Description: NEW CHURCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/25/2006 | REVISION - WALK THRU | 01/25/2006 | COMPLETED |
| 03/08/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 04/07/2006 | COMPLETED |
| 06/21/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 06/21/2005 | COMPLETED |
| 06/21/2005 | SITE | 10/05/2005 | COMPLETED |
| 06/21/2005 | 3RD PARTY REVIEW-COMMERCIAL | 09/19/2005 | COMPLETED |
| 09/19/2005 | POST 3RD PARTY REVIEW | 10/05/2005 | COMPLETED |
| 10/06/2005 | RESUBMITTAL | 11/22/2005 | COMPLETED |
| 10/06/2005 | RESUBMITTAL - SITE | 11/22/2005 | COMPLETED |
| 10/19/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 10/31/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02886
Permit Status: C of o
Permit Description: NEW CHURCH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/21/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM02886
Permit Description: NEW CHURCH
Total Completed Inspections - 46
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2006 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :*3/0 CUT TO REBAR |
| 01/26/2006 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | IVRS - Inspection :* |
| 03/23/2006 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* SEE NOTE FROM 3/8/06 INSPECTION AND COMPLY! |
| 04/03/2006 | ROOF NAILING | JCAGLE | Approved | IVRS - Inspection :* |
| 05/31/2006 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* GANG RESTROOM REQUIRES CORRECT TRAP PRIMER INSTALL. GANG RESTROOM TO HAVE CORRECT REVISED VENTING INSTALLED CORRECTLY. ENGINEER TO PROVIDE SIZING FOR PIPING & SEAL STAMP FOR ALTERNATE HANGER DETAIL FLOOR SINKS TO BE INSTALLED & CLOSET FLANGES TO BE INSPECTED PRIOR TO SETTING STOOLS. |
| 05/31/2006 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* |
| 06/28/2006 | ELECTRIC - PROGRESS | RSUBA | Approved | IVRS - Inspection :* |
| 08/04/2006 | TEP CLEARANCE - AM | BFLORES | Approved | ECO PER R.SUBA |
| 09/14/2006 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* PRE-FINAL |
| 10/25/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 15 PSI TEST ON SYSTEM OK |
| 10/31/2006 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 10/31/2006 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 10/31/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
| 11/07/2006 | ENGINEERING - FINAL | NKALAHAR | Approved | DUMPSTER AND EQUIPMENT TO BE PICKED UP ISSUES ATTACHED TO GRADING PERMIT: MISSING STRIPING AT ASPHALT PATCH DRAINAGE WORK NOT YET COMPLETE OFF SITE (LANDSCAPING) BASIN CERTIFICATION LETTER NEEDED PER PAUL MACHADO CHANGE IN DRAINAGE PIPE MUST BE SUBMITTED ON A REVISED GRADING PLAN WITH ELEVATIONS, PIPE SLOPE AND MAINTENANCE AGREEMENT. |
| 11/07/2006 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 11/08/2006 | SIGN - FINAL | JYBARRA | Approved | SIGN PERMIT OBTAINED |
| 11/14/2006 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* |
| 11/14/2006 | FIRE - KITCHEN EXH HOOD FINAL | LTHOMAS | Approved | No kitchen exhaust hood fire suppression system required. |
| 11/14/2006 | FIRE - FINAL | LTHOMAS | Approved | |
| 11/14/2006 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 11/14/2006 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 11/14/2006 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 11/14/2006 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 11/17/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* AIR BALANCE QUANTITIES ARE ACCEPTABLE OK FOR FINAL |
| 11/17/2006 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 11/17/2006 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 11/21/2006 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | |
| 11/21/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 11/21/2006 | PERMIT FINALED | DROBEY | Approved | |
| 11/21/2006 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | |
| 11/21/2006 | OUTDOOR LIGHTING FINAL | RSUBA | Approved | |
| 11/21/2006 | ELECTRIC - OUTDOOR LIGHTING | RSUBA | Approved | |
| 11/21/2006 | ELECTRIC - CABLE DROP | RSUBA | Approved | |
| 11/21/2006 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | |
| 11/21/2006 | ELECTRIC - UNDERGROUND | RSUBA | Approved | |
| 11/21/2006 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | |
| 11/21/2006 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* |
| 11/21/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* |