Permit: T05CM02886

Parcel: 14118001D


Addresses:

10220 E REES LP


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T05CM02886

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
05/31/2006 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
GANG RESTROOM REQUIRES CORRECT TRAP PRIMER INSTALL.
GANG RESTROOM TO HAVE CORRECT REVISED VENTING INSTALLED CORRECTLY.
ENGINEER TO PROVIDE SIZING FOR PIPING & SEAL STAMP FOR ALTERNATE HANGER DETAIL FLOOR SINKS TO BE INSTALLED & CLOSET FLANGES TO BE INSPECTED PRIOR TO SETTING STOOLS.
01/31/2006 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
01/23/2006 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) PROVIDE TEST FOR LEAK AT 90 DEGREE 20' FROM METER LOCATION-PIPING FROM METER TO 5' FROM BLDG PVC SCHEDULE 40. (1) NEED TO VIEW RPB INSTALL AND CONNECTION TO BLDG
01/20/2006 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
01/19/2006 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
2" PVC SCH 40 FROM 30' FROM CURB TO BUILDING WITH TRACER OK - NEED PRESSURE TEST PRIOR TO BACKFILL.