Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T05CM02886
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2006 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* SEE NOTE FROM 3/8/06 INSPECTION AND COMPLY! |
|
| 03/20/2006 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTE FROM 3/1/06 INSPECTION. HAVE YOUR APPROVED LISTED GLUE ON SITE USE ABS TO PVC TRANSITION GLUE THAT IS LISTED THIS IS TYPICALLY GREEN. |
|
| 03/01/2006 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* PROVIDE CORRECT PRIMER & GLUE FOR PVC TO ABS TRANSITION OR PROVIDE CORRECT COUPLING FOR THAT TRANSITION |
|
| 01/19/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
| 01/17/2006 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* |