Permit: T04CM03716
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
6720 S RENAISSANCE DR
Address NEW:
6720 S RENAISSANCE DR
Apply Date:
08/12/2004
Applicant:
ARCHITECTURE WEST
Description:
OFFICE BLDG/MAINTENANCE:NEW
Contractors:
- A P N BUILDERS INC
Permit Reviews
Permit Number - T04CM03716
Permit Status: C of o
Permit Description: OFFICE BLDG/MAINTENANCE:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/12/2005 | RESUBMITTAL | 01/27/2005 | COMPLETED |
| 01/27/2005 | RESUBMITTAL | 02/03/2005 | COMPLETED |
| 02/07/2005 | RESUBMITTAL | 02/07/2005 | COMPLETED |
| 08/12/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 08/13/2004 | COMPLETED |
| 08/13/2004 | PLANS OK TO SUBMIT - SITE | 08/13/2004 | COMPLETED |
| 08/16/2004 | SITE | 09/27/2004 | COMPLETED |
| 08/18/2004 | COMMERCIAL NEW | 09/27/2004 | COMPLETED |
| 09/14/2005 | REVISION | 09/15/2005 | COMPLETED |
| 10/26/2004 | RESUBMITTAL - SITE ALL | 12/01/2004 | COMPLETED |
| 10/26/2004 | RESUBMITTAL | 12/01/2004 | COMPLETED |
| 12/09/2004 | RESUBMITTAL - SITE | 01/11/2005 | COMPLETED |
| 12/09/2004 | RESUBMITTAL | 01/11/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03716
Permit Status: C of o
Permit Description: OFFICE BLDG/MAINTENANCE:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/12/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM03716
Permit Description: OFFICE BLDG/MAINTENANCE:NEW
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* APPROVED |
| 02/22/2005 | STEM WALL/RETAINING WALL | AMATHIES | Approved | APPROVED |
| 02/28/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) HCS CONNECTION IS OK 3) OK TO BACKFILL TRENCH |
| 02/28/2005 | SITE - SEWER | TRINIVJR | Approved | 1) SOIL WATER TEST IS OK 2) OK TO BACKFILL TRENCH |
| 02/28/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) BLDG DRAIN IS STUBBED OUT @ TWO WAY C.O ONLY. 3) AIR PRESSURE TEST FOR 2" C. W. SUPPLY IS OK 4" OUT OF STRUCTURE. 4) OK TO BACKFILL TRENCH. |
| 03/04/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* APPROVED |
| 04/07/2005 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection :* |
| 04/28/2005 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection :* 1) YARD WATER LINE IS OK FORM METER TO BLDG SERVICE 2) OK TO BACKFILL TRENCH. |
| 06/14/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 06/14/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 06/14/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
| 06/14/2005 | EXT METAL CLIPS/EXT SHEATHING | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/16/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* 1) OVERHEAD WATER DISTRIBUTION IS OK. 2) GAS PRESSURE TEST IS OK. 3) CLOSET RINGS HAVE BEEN SET. |
| 06/16/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* |
| 07/15/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 08/08/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) PLUMBING FINAL IS OK 2) OK FOR C OF O |
| 08/08/2005 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | ok clear PER EMAIL |
| 08/08/2005 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection :* |
| 08/08/2005 | PLUMBING - ROOF DRAINS | TRINIVJR | Approved | IVRS - Inspection :* |
| 08/08/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
| 08/08/2005 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 08/08/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 08/08/2005 | SIGN - FINAL | RDEAR | Approved | IVRS - Inspection :* |
| 08/29/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 08/29/2005 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 08/29/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 08/30/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | |
| 08/30/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 08/30/2005 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 08/30/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* 1) OK TO CLEAR ECO 1) NO BOND REQUIRED |
| 08/30/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 08/30/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 08/31/2005 | ENGINEERING - FINAL | MAVERY | Approved | Contractor completed punch-list. |
| 08/31/2005 | TEP CLEARANCE - AM | RMAJUTA | Approved | ECO SENT TO TEP PER SANTACRUZ |
| 09/09/2005 | PERMIT FINALED | GBONILLA | Approved |