Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T04CM03716
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/27/2004 | Andrew Connor | LANDSCAPE | REVIEW | Denied | 1. Street landscape border is a landscape area running the full length of the street property line bounding the site except for points of ingress-egress per LUC 3.7.2.4 additional border requirements are needed for street boundaries to the south. 2. Additional screening is required for truck parking to the south per LUC table 3.7.2.I 3. Retention basin is considered the landscape requirement for that portion of Renaissance Dr. 50 percent or more of the area of the street landscape border must be covered with shrubs or vegetative ground cover. LUC 3.7.2.4.A.4. Include calculation for coverage with resubmitted. |
| 10/29/2004 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 11/14/2004 | DAVID RIVERA | HANDICAP-SITE | REVIEW | Approved | |
| 11/14/2004 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 11/16/2004 | Doug Williams | ENGINEERING | REVIEW | Denied | SUBJECT: Drainage Report, Site, Grading, and Stormwater Pollution Prevention plan review DATE: 16 November 2004 ACTIVITY NUMBERS: T04CM03716/T04BU02032 T15S, R13E, Section 15 Engineering Division has reviewed the Subject items. Approvals of the site and grading plans may not be recommended prior to provision of a minimum recommended setback from the retention/detention basins (ref. Previous drainage report comment # 2), and modifications to the proposed dumpster enclosure. The following comments must be addressed prior to Engineering Division approval: SITE AND GRADING PLANS: 1. Please refer to previous "drainage report" comment #2 - this item must be addressed prior to recommendation for site and grading plan approvals: Discuss and provide recommendations for minimum setbacks from the retention basins for the proposed building, or provide additional geotechnical engineering recommendations - the soils report does not specifically address minimum setbacks, as required per Section14.2.6 of the Drainage Standards Manual (DS 10-02.0). 2. The 14' x 40' clear approach depicted does not allow for a solid waste vehicle to gain access to the point of origin depicted, nor does the proposed location appear to allow for minimum inside and outside turning radii of 36' and 50', respectively. Revise the enclosure angle to allow for direct access to the enclosure from the PAAL/driveway (approximately 30° rather than 45° may allow for such), or provide written approval from Environmental Services Department for the configuration depicted/proposed - preferably on the site plan (DS 2-02.2.1.32 & DS 6-01.4.0). STORMWATER POLLUTION PREVENTION PLAN (SWPPP): 1. Please provide/include page 2 of 2 of the signed Notice of Intent (NOI) in each SWPPP text. 2. Delineate the total area to be disturbed on sheet C5.0 - including the protected material(s) storage area and washout basin areas. These areas should be included in the total area of disturbance calculated. An over-the-counter approval may be coordinated with me if desired, upon completion/provision of the above items. If you have any questions, I can be reached at 791-5550, extension 1189 or Doug.williams@tucsonaz.gov Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department City of Tucson |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/01/2004 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/01/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |