Permit: T03CM03908
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
2200 N CAMINO PRINCIPAL
Address NEW:
2200 N CAMINO PRINCIPAL
Apply Date:
08/06/2003
Applicant:
SAM O'SHAUGHNESSY
Description:
NEW:RESTAURANT
Architects:
- A D C
Contractors:
- MARIACHER CONTRACTING CO
Permit Reviews
Permit Number - T03CM03908
Permit Status: C of o
Permit Description: NEW:RESTAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/11/2005 | REVISION - WALK THRU | 02/11/2005 | COMPLETED |
| 02/15/2005 | REVISION - 2ND | 02/15/2005 | COMPLETED |
| 03/09/2004 | 3RD PARTY REVIEW-COMMERCIAL | 10/13/2004 | COMPLETED |
| 05/04/2005 | REVISION - 2ND | 05/09/2005 | COMPLETED |
| 05/09/2005 | REVISION | 05/09/2005 | COMPLETED |
| 05/11/2005 | REVISION | 05/11/2005 | COMPLETED |
| 05/23/2005 | REVISION - SITE | 06/15/2005 | COMPLETED |
| 05/26/2005 | REVISION | 05/26/2005 | COMPLETED |
| 06/15/2005 | REVISION - SITE | 07/08/2005 | COMPLETED |
| 07/11/2005 | RESUBMITTAL | 08/24/2005 | COMPLETED |
| 08/06/2003 | SITE | 09/22/2003 | COMPLETED |
| 08/07/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 08/07/2003 | COMPLETED |
| 08/07/2003 | 3RD PARTY REVIEW-COMMERCIAL | 08/20/2003 | COMPLETED |
| 08/07/2003 | 3RD PARTY REVIEW-COMMERCIAL | 03/09/2004 | COMPLETED |
| 09/06/2005 | RESUBMITTAL | 09/06/2005 | COMPLETED |
| 10/10/2003 | 3RD PARTY REVIEW-COMMERCIAL | 10/21/2003 | COMPLETED |
| 10/13/2004 | COMMERCIAL NEW | 01/19/2005 | COMPLETED |
| 12/28/2007 | REVISION - SITE | 01/03/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03908
Permit Status: C of o
Permit Description: NEW:RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/06/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM03908
Permit Description: NEW:RESTAURANT
Total Completed Inspections - 45
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2005 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* |
| 03/07/2005 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection :*APPROVED |
| 03/08/2005 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* 1) MIKE KISER FROM TEP SAYS ?? CURRENT IS LESS THAN OK OK TO TEMP SERVICE |
| 03/22/2005 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/22/2005 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/23/2005 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* OK 4" PVC IN TRENCH FROM BUILDING TO WITHIN 10" OF PULL BOX. 1) NO PULL BOX ON PLANS. 2) ABOVE GRADE TO BE SCHEDULE 80 |
| 05/12/2005 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection :* |
| 05/12/2005 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection :* |
| 05/24/2005 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 05/24/2005 | FRAMING | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/03/2005 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST OK |
| 06/09/2005 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 06/09/2005 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 06/09/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 06/16/2005 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* 1) COPPER ABOVE CEILING INSULATED OK. 2) BACKWATER VALVES INSTALLED PER PLAN. |
| 06/16/2005 | PLUMBING - BACK WATER VALVE | RMYERS | Approved | IVRS - Inspection :* |
| 07/26/2005 | BUILDING ABOVE CEILING | HLEYVA | Approved | |
| 09/20/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* INSPECTION ON ABOVE CEILING IN DINING AREA ONLY. OK FOR CEILING TILES |
| 09/20/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 09/20/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 09/20/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 10/03/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
| 11/18/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 11/21/2005 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 12/02/2005 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* CHECKED FIRE WRAP ON WELDED DUCT OK TO PROCEED. |
| 12/08/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) A/C UNIT NOT FUSED CORRECTLY 2) SEE UNIT DATA PLATE 3) OK FOR TEMP C OF O |
| 12/12/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :*FILL UNUSED OPENINGS IN PANEL. PLEASE VERIFY LISTING LABELS ON ALL EQUIPMENT PLEASE PROVIDE A LETTER FOR DELETED PATIO LIGHTING PLEASE VERIFY DERATING FOR DIMMERS LIGHTS & FANS ROOF: TIGHTEN LOOSE FITTINGS LABEL DISCONNECTS AT PANEL IDENTIFY CONDUCTORS AT TERMINALS PROTECT SEALTITE/NON ?? FLEX FROM SHARP METAL EDGES WHERE IS MAINTANCE RECEPTICAL 210.63 PLAN DO NOT SHOW PANEL ON ROOF |
| 12/14/2005 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | |
| 12/14/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE OK FOR C OF O |
| 12/21/2005 | ENGINEERING - FINAL | DROBERTS | Approved | MET ON-SITE WITH SAM O'SHAUGHNESSY TO DISCUSS THE WORK THAT WILL BE REQUIRED PRIOR TO THE ISSUANCE OF A TEMPORARY C OF O. HE GAVE ME A COPY OF THE RESPONSE TO ALL OF THE ITEMS THAT HAVE BEEN PREVIOUSLY ADDRESSED, SOME OF THESE RESPONSES WILL HAVE TO BE APPROVED BY THE ENGINEERING AND ZONING REVIEWER FOR THIS SITE BEFORE A TEMPORARY C OF O CAN BE ISSUED. THIS COPY OF THE COMMENTS HAVE BEEN PLACED WITH THE INSPECTION RESULTS FOR THIS DATE. I HAVE ALSO TAKEN PHOTO'S OF THE SITE TO SHOW THE CURRENT CONDITIONS OF THE SITE AS OF THIS DATE. THESE PHOTO'S HAVE BEEN GIVEN TO THE DEPARTMENT HEADS OF ZONING AND ENGINEERING TO HELP WITH THIER DECISION ON WHAT IS TO BE DONE WITH THIS SITE AT THIS TIME. |
| 12/21/2005 | FIRE - FINAL | LLAKEY | Approved | |
| 12/21/2005 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 12/23/2005 | BUILDING - FINAL | JCAGLE | Approved | IVRS - Inspection :*OK FOR TEMP C OF O |
| 01/09/2006 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/11/2006 | EXCAVATION/LAYOUT REBAR & ZON | JCAGLE | Approved | |
| 01/11/2006 | STEM WALL/RETAINING WALL | JCAGLE | Approved | |
| 01/11/2006 | REINFORCED MASONRY PRE-GROUT | JCAGLE | Approved | |
| 02/07/2006 | HEALTH DEPT - FINAL 724-7908 | ELOPEZ | Approved | PER HEALTH DEPT REPORT COPY |
| 02/09/2006 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | |
| 02/09/2006 | ELECTRIC - TEMPORARY POLE | RHOLLAND | Approved | |
| 09/29/2009 | FIRE SPKLR - FINAL | DRAMIREZ | Approved | |
| 09/29/2009 | FIRE SPKLR - UG PIPING FLUSH | DRAMIREZ | Approved | |
| 10/06/2009 | PERMIT FINALED | BGRANT | Approved | |
| 10/06/2009 | LANDSCAPE - FINAL | JLINVILL | Approved | |
| 10/06/2009 | NPPO - FINAL | JLINVILL | Approved | OK FOR C OF O |