Permit: T03CM03908

Parcel: 13315305A

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/09/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
09/20/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/29/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :* SECURE CONDUITS @ PANEL
04/15/2005 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) SEPARATE AND SECURLY SUPPORT M/C CABLES SO AS NOT TO BOND?? CABLES 310-15 (2) ( A0. 2) SUPPORT M/C CABLES AS PER CODE 12' FROM BOXES AND PANEL, AND 6' ON HORIZONTAL AND VERTICAL RUNS 3) PLEASE PREVENT DIE ELECTRIC CONTACT WITH COPPER PIPING. 4) PROTECT CONDUCTOR AT STUDS 300.4 5) SUPPORT CONDUITS WITHIN 3' OF BOXES AND PANEL. 6) BOXES IN STUCCO FOAM WILL NEED APPROVED EXTENDER RINGS OR BROUGHT FLUSH OUT OF COMBUSTIBLES 370-20. 7) WHERE AFTER THE ELECTRICAL PLANS.