Start Date Submittal Complete Date Status  
04/16/2025 DEVELOPMENT PACKAGE NEW v.5 04/18/2025 APPROVED Review Details
04/04/2025 DEVELOPMENT PACKAGE NEW v.4 04/14/2025 REQUIRES RESUBMIT Review Details
11/29/2024 DEVELOPMENT PACKAGE NEW v.1 12/10/2024 REQUIRES RESUBMIT Review Details
12/11/2024 DEVELOPMENT PACKAGE NEW v.2 02/06/2025 REQUIRES RESUBMIT Review Details
02/13/2025 DEVELOPMENT PACKAGE NEW v.3 03/19/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-1124-00319
Permit Status: Inspections complete
Permit Description: McDonald's - Valencia Crossings
Total Outstanding Activity Conditions - 2
Date Name
02/04/2026 Prior to final - needs review for requests for information, AS-Built will need to be submitted
10/02/2025 CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TD-DEV-1124-00319
Permite Description: McDonald's - Valencia Crossings
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
07/24/2025 SITE - Sign Footer/Setback/Excavation Layout/Rebar N/A Partial Pass 07/24/25, monument board, call board, canopy. Ground to board. All good to pour.
07/25/2025 COT - FCON - Fire - Final N/A Not Applicable
11/05/2025 N/A Partial Pass Contractor is good to put aggregate base on the subgrade in the parking lot and the drive-through area
09/18/2025 ENGR - Drainage Structures N/A Partial Pass Okay to pour2 EF1’s & invert of junction structure
06/25/2025 For trash and recycling enclosures N/A Partial Pass Rebar spacing and clearance is good, okay to pour slab.
12/18/2025 LAND Landscape Appearance & Function Final N/A Partial Pass The Landscaped areas adjacent to the building are complete. The areas adjacent to the road are in process of being completed and are almost 100%. Areas along the Street are almost complete with the exception of the area next to the temporary Silting Basin. Areas away from the building on far side of parking lot to the East, North and west are in process. 2 of 3 PIP Were preserved. 1 Fishhook will be mitigated.
The Nursery did not do well. Only 2 Palo Verde are viable.
TOS mitigation required:
1 Ironwood
2 Palo Verde.
1 Velvet Mesquite
2 Fishhook Barrell
Plants and Materials correct in Finished areas. Equipment Correct. Irrigation functioning.
Disturbed areas to the East and NE of site will need to have any construction debris removed and the area needs to be revegetated with hydroseed.
10/03/2025 N/A Partial Pass continue installing irrigation lines.
12/15/2025 ENGR Engineering Final N/A Partial Pass Contractor needs to complete all the landscaping.
Contractor needs to patch the area where they had a water leak underneath the asphalt. The entrance on the Valencia going west.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TD-DEV-1124-00319
Permit Description: McDonald's - Valencia Crossings
Total Completed Inspections - 14
Date Description Inspector Results Comments
05/13/2025 PDSD Engineering Division Pre-Construction SITE Passed Awaiting email from contractor with contact information.
05/19/2025 NPPO Pre-Construction Passed NPPO items are good. Plants are identified for preservation and protected as necessary, temp nursery location is ready. Okay to begin grubbing.
09/03/2025 Passed Good to backfill all remaining pipe, compaction results can be submitted to both inergov and the portal.
12/09/2025 Passed
12/09/2025 Passed
12/15/2025 SITE - Zoning Final Passed
12/17/2025 ENGR Paving Passed Paving is complete and in accordance with approved plans.
12/18/2025 ENGR Grading Final Passed 12/18/25 Grading is currently being completed. The West Basin top is built correct to plan. EOR has approved changes to the Temporary Silting Basin. It has not been finished but should be built to the Engineers specifications.This is a Drainage structure and will be inspected as such at Final.
02/02/2026 ENGR - Drainage Structures Passed
02/02/2026 For trash and recycling enclosures Passed
02/04/2026 LAND Landscape Appearance & Function Final Passed 2/4/26
Disturbed areas North and East os site have been cleaned smoothed and hydro seeded. Other areas were DG'd. NPPO was checked and okayed and plants and equipment are in place. Plants look healthy.
02/04/2026 Passed 2\4\26
Equipment is in place. Irrigation is functioning and plants look to be doing well.
02/04/2026 NPPO Final Passed 2/4/26
I went through the history NPPO. Brian initially noted issues but then approved of the nursery. The nursery had a hard time over the summer. But the plants that did survive were replanted and are on irrigation. I can Identify 1 large Palo Verde but unfortunately that is it. The few viable trees that survived that I saw were viable are mixed in. No Barrels survived the nursery. However I have counted 11 Barrels in the landscape and they are doing well. That is more than viable TOS and PIP.

The PIP mesquite is doing well and Total amount of Mesquite in landscape is greater than TOS and PIP.

Total Palo Verde is also greater than TOS PV

I also identified 1 healthy Iron Wood and There was 1 TOS Iron Wood.
02/18/2026 ENGR Engineering Final Passed

Documents

File Name Document Type  
4_TD_DEV_1124-00319 DEVELOPMENT PACKAGE_V5.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_TD-DEV-1124-00319_DRC APPROVAL LETTER.PDF DOCUMENTS VIEW
RESPONSE LETTER.PDF DOCUMENTS VIEW