Permit: TC-MDP-0524-00635
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
1671 S SAN JOSE DR UNIT 1
Address NEW:
1671 S SAN JOSE DR UNIT 1
Apply Date:
06/12/2024
Applicant:
Description:
GC model 100 duplex
Permit Reviews
Permit Number - TC-MDP-0524-00635
Permit Status: Complete
Permit Description: GC model 100 duplex
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/25/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 08/06/2024 | REQUIRES RESUBMIT |
| 06/21/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 07/02/2024 | REQUIRES RESUBMIT |
| 08/22/2024 | RESTAMP - RESIDENTIAL v.1 | 08/27/2024 | APPROVED |
| 06/14/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 06/14/2024 | REQUIRES RESUBMIT |
| 08/09/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 | 08/22/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0524-00635
Permit Status: Complete
Permit Description: GC model 100 duplex
| Date | Description | Comments |
|---|---|---|
| 06/14/2024 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 05/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 05/17/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0524-00635
Permite Description: GC model 100 duplex
Total Outstanding Inspections - 11
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/02/2025 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | 01/02/2025 East firewall on unit 1 is missing drywall screws above ceiling. All joints have to be taped above ceiling. Missing blocking above west window in kitchen. Missing drywall screws in northeast bedroom. unit 2: Firewall needs screws above ceiling line. also needs tape on all joints above ceiling. |
| 01/15/2025 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | 01/15/25 Water line not under test. Must also have a gauge showing 60 psi in the lines. |
| 01/15/2025 | COT - RSPL - Sewer | N/A | Re-inspection required | 01/15/25 Sewer line not under test and missing green tracer wire. |
| 01/15/2025 | COT - RSPL - Backwater Valve | N/A | Re-inspection required | 01/15/25 Sewer line not under test and missing green tracer wire. |
| 05/20/2025 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 05/20/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 05/20/2025 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 06/23/2025 | COT - RSME - Mechanical Final | N/A | Re-inspection required | Provide plans on site. Provide vacuum breakers at exterior hose bibs. Coat all exterior pipes. Add mud to exterior for exposure of plumbing. Exterior receptacles need to be WR and do not reset. Properly insulate exterior water lines. Missing anti tip for stove. Provide hammer arrestor on hot line for dishwasher. Cut down clean out and provide proper caps. Seal all exterior penetrations. Provide ladder for roof access. Electrical panel has not been made up. Receptacle in bedroom missing yolk. Stopped inspection. Other items may apply. 5/20/2025 6/23/25: proper clean out covers required at driveway, UV tape required at insulation on exterior hose-bibs, GFCI receptacles required at exterior, all exterior plastic piping must be coated for UV protection, leak at hose bib that is kinked, Arc-fault breakers required throughout, anti-tip required, GFCI required at garbage disposal, cut Cleanouts and add proper caps, GFCI at laundry, exhaust fan covers must be installed, properly secure liquid tight at water heater disconnect box, T&P must terminate in pan, no roof access. |
| 06/23/2025 | RSBU - Building Final | N/A | Re-inspection required | Provide plans on site. Provide vacuum breakers at exterior hose bibs. Coat all exterior pipes. Add mud to exterior for exposure of plumbing. Exterior receptacles need to be WR and do not reset. Properly insulate exterior water lines. Missing anti tip for stove. Provide hammer arrestor on hot line for dishwasher. Cut down clean out and provide proper caps. Seal all exterior penetrations. Provide ladder for roof access. Electrical panel has not been made up. Receptacle in bedroom missing yolk. Stopped inspection. Other items may apply. 5/20/2025 6/23/25: proper clean out covers required at driveway, UV tape required at insulation on exterior hose-bibs, GFCI receptacles required at exterior, all exterior plastic piping must be coated for UV protection, leak at hose bib that is kinked, Arc-fault breakers required throughout, anti-tip required, GFCI required at garbage disposal, cut Cleanouts and add proper caps, GFCI at laundry, exhaust fan covers must be installed, properly secure liquid tight at water heater disconnect box, T&P must terminate in pan, no roof access. per City of Tucson all inclusive home design please provide an accessible route/entrance per approved plans. |
| 06/23/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | Provide plans on site. Provide vacuum breakers at exterior hose bibs. Coat all exterior pipes. Add mud to exterior for exposure of plumbing. Exterior receptacles need to be WR and do not reset. Properly insulate exterior water lines. Missing anti tip for stove. Provide hammer arrestor on hot line for dishwasher. Cut down clean out and provide proper caps. Seal all exterior penetrations. Provide ladder for roof access. Electrical panel has not been made up. Receptacle in bedroom missing yolk. Stopped inspection. Other items may apply. 5/20/2025 6/23/25: proper clean out covers required at driveway, UV tape required at insulation on exterior hose-bibs, GFCI receptacles required at exterior, all exterior plastic piping must be coated for UV protection, leak at hose bib that is kinked, Arc-fault breakers required throughout, anti-tip required, GFCI required at garbage disposal, cut Cleanouts and add proper caps, GFCI at laundry, exhaust fan covers must be installed, properly secure liquid tight at water heater disconnect box, T&P must terminate in pan, no roof access. |
| 06/23/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | Provide plans on site. Provide vacuum breakers at exterior hose bibs. Coat all exterior pipes. Add mud to exterior for exposure of plumbing. Exterior receptacles need to be WR and do not reset. Properly insulate exterior water lines. Missing anti tip for stove. Provide hammer arrestor on hot line for dishwasher. Cut down clean out and provide proper caps. Seal all exterior penetrations. Provide ladder for roof access. Electrical panel has not been made up. Receptacle in bedroom missing yolk. Stopped inspection. Other items may apply. 5/20/2025 6/23/25: proper clean out covers required at driveway, UV tape required at insulation on exterior hose-bibs, GFCI receptacles required at exterior, all exterior plastic piping must be coated for UV protection, leak at hose bib that is kinked, Arc-fault breakers required throughout, anti-tip required, GFCI required at garbage disposal, cut Cleanouts and add proper caps, GFCI at laundry, exhaust fan covers must be installed, properly secure liquid tight at water heater disconnect box, T&P must terminate in pan, no roof access. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0524-00635
Permit Description: GC model 100 duplex
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2024 | COT - RSPL - Rough Soil | Passed | Ok to cover progress areas. | |
| 09/12/2024 | COT - RSBU - Preslab | Passed | Ensure slab area is properly termite treated | |
| 09/12/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 11/05/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11/5/2024 corrections were made. Approved. | |
| 11/05/2024 | COT - RSBU - Roof Nailing | Passed | 11/5/2024 corrections were made. Approved. | |
| 12/20/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/20/24 corrections have been made, ok to proceed. | |
| 01/03/2025 | COT - RSBU - Interior Shear Bracing | Passed | 1-3-25, interior shear approved. Okay to tape & texture drywall. | |
| 01/17/2025 | COT - RSPL - Yard Water Line | Passed | 01/17/25 Passed. OK to backfill shading required. |
|
| 01/17/2025 | COT - RSPL - Sewer | Passed | 01/17/25 Passed. OK to backfill shading required. |
|
| 01/17/2025 | COT - RSPL - Backwater Valve | Passed | 01/17/25 Passed. |
|
| 04/17/2025 | BULD - Electrical Clearance | Passed | 4-17-25, okay to energize panel. ECO clearance issued to TEP. | |
| 05/20/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 05/21/2025 | ENGR Engineering Final | Passed | Site is clean and safe, in accordance with approved plans. CofO ready. | |
| 05/20/2025 | RSBU - Building Progress | Passed | ||
| 06/23/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 07/09/2025 | COT - RSME - Mechanical Final | Passed | ||
| 07/09/2025 | RSBU - Building Final | Passed | ||
| 07/09/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 07/09/2025 | COT - RSEL - Electrical Final | Passed |