Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Outdoor Lighting

Date Description Inspector Results Comments
05/20/2025 COT - RSEL - Outdoor Lighting Re-inspection required Provide vacuum breakers at exterior hose bibs. Coat all exterior pipes. Add mud to exterior for exposure of plumbing. Exterior receptacles need to be WR and do not reset. Properly insulate exterior water lines. Missing anti tip for stove. Provide hammer arrestor on hot line for dishwasher. Cut down clean out and provide proper caps. Seal all exterior penetrations. Provide ladder for roof access. Electrical panel has not been made up. Receptacle in bedroom missing yolk. Stopped inspection. Other items may apply. 5/20/2025
06/23/2025 COT - RSEL - Outdoor Lighting Passed