Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
11/27/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready 11/27/25. Not ready
12/06/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 11/27/25. Not ready
12/6/24: seal all penetrations through vapor barrier (rips,tears,staples), seal all penetrations through top plate throughout, seal bottom plate with foam, FHA plate required at dryer exhaust vent, grey water piping required (not installed), 2 lights required per plan in closet, wire size at multiple circuits not per plan, carbon monoxide detector and smoke detector missing outside of bedrooms, receptacles missing at exterior, plumbing at shower/tub not complete and not under test, multiple circuits tied together. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
12/18/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready 12/18/24. Stud shoes required at 2x4 where 2" PVC runs through, fire blocking required at main service panel (Check top plates as well). Exterior lights must have receptacle, grounded and sealed. RE INSPECTION required. NOT READY. Revised plans also have been sent in but not approved. DO NOT PROCEED.
12/20/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12/20/24 corrections have been made, ok to proceed.