Permit: TC-COM-0525-01018
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
701 W CONGRESS ST
Address NEW:
701 W CONGRESS ST
Apply Date:
05/19/2025
Applicant:
Carina Eichorst
Description:
New single 4-story multi-family apartment building.
Permit Reviews
Permit Number - TC-COM-0525-01018
Permit Status: Inspections
Permit Description: New single 4-story multi-family apartment building.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/14/2025 | COMMERCIAL REVIEW - FULL v.4 | 11/14/2025 | APPROVED |
| 09/02/2025 | COMMERCIAL REVIEW - FULL v.3 | 09/30/2025 | REQUIRES RESUBMIT |
| 08/06/2025 | COMMERCIAL REVIEW - FULL v.2 | 08/29/2025 | REQUIRES RESUBMIT |
| 05/20/2025 | COMMERCIAL REVIEW - FULL v.1 | 06/27/2025 | REQUIRES RESUBMIT |
| 11/14/2025 | RESTAMP - COMMERCIAL v.1 | 11/14/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0525-01018
Permit Status: Inspections
Permit Description: New single 4-story multi-family apartment building.
Total Outstanding Activity Conditions - 10
| Date | Name |
|---|---|
| 05/20/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
| 09/09/2025 | AIR BALANCING REPORT IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 09/09/2025 | Post-Installed Anchor Inspection Report is required. |
| 09/09/2025 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR fabricated systems and elements IS REQUIRED |
| 09/09/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
| 09/09/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0525-01018
Permit Status: Inspections
Permit Description: New single 4-story multi-family apartment building.
| Date | Description | Comments |
|---|---|---|
| 05/20/2025 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 05/20/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 05/20/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 10/31/2025 | Must be approved by Deputy Director Elisa Hamblin prior to permit issuance |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0525-01018
Permite Description: New single 4-story multi-family apartment building.
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2025 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | 12/16/25: Plumbing underground approved for GL A-C/1.5-3, (pending GL A-B/1-1.5) |
| 12/23/2025 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | 12/23/25: TMPP CLEARANCE FOR 701 W CONGRESS ST (Temp power for construction trailer) |
| 12/23/2025 | BULD - Electrical Clearance | N/A | Partial Pass | 12/23/25: TMPP CLEARANCE FOR 701 W CONGRESS ST (Temp power for construction trailer) |
| 12/30/2025 | COT - HCBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Footings for stem wall and vapor barrier are in place. OK to place concrete in progress areas. |
| 12/30/2025 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | Footings throughout slab area and slab area (vapor barrier) are in place. Slab area has been termite treated. Ok to place concrete in slab area. |
| 02/17/2026 | COT - HCBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 2/17/26: anchor bolt spacing at non shear-walls shall be 48" o.c, anchor bolts at SW3 required to be spaced at 16" o.c, interior SW3 sill plate attached shot pins 6" o.c, all anchor bolts must be properly fastened, anchor bolts required within 12" from edge of sill plate and no less than 7x the bolt diameter, sheathing at shear walls must be fastened per approved plans and shall be fastened no closer then 3/8" from edge and shall not penetrate more than 1/8", submit revised set of plans to city for approval, units 101,102,103,104,105,106,107,108,109 and 100C were all walked and the notes are identical for all units. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0525-01018
Permit Description: New single 4-story multi-family apartment building.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2025 | PDSD Heavy Commercial Building Division Pre-Construction Meeting | Passed |