Permit: TC-COM-0525-01018

Parcel: 11619131A


Addresses:

701 W CONGRESS ST

Inspection Status: Partial Pass

Inspection History: COT - HCEL - Electrical Intermediate

Date Description Inspector Results Comments
04/12/2026 COT - HCEL - Electrical Intermediate Partial Pass 4/10/26: UNIT 420 COURTESY WALKTHROUGH FOR M.E.P approved in wall only
04/15/2026 COT - HCEL - Electrical Intermediate Partial Pass 4/14/26: 4th floor units electrical in-wall approved. Above ceiling partial pass pending drop ceiling
04/23/2026 COT - HCEL - Electrical Intermediate Partial Pass 4/23/2026 in wall electrical 3rd floor units 320,319,318,317,316,315,314,313,312. Approved. Pending drop ceiling.
05/05/2026 COT - HCEL - Electrical Intermediate Partial Pass 5/5/2026 partial pass. In wall electrical 2nd floor west and north units approved.
05/14/2026 COT - HCEL - Electrical Intermediate Partial Pass 5/14/2026 Partial pass. 2nd & 3rd floor corridors in walls at west end only approved. Pending north section due to spray foam installation at the time.
05/18/2026 COT - HCEL - Electrical Intermediate Re-inspection required 5/18/26: 2nd and 3rd floor corridors in walls at north building approved. In-wall MEP of 1st floor rooms (101,102,103,104,105,106,107,108,109,110,111,113,114) re-inspection required. Nail plates improperly installed must have (8) 3 -1/2" nails on both sides of 5x18 nail/strap, 5-sided gypsum box required at refrigerator water supply box, seal all penetrations at exterior and interior Fire walls, studs over notched at corridor require fix,properly secure electrical box at bathroom in room 106, room 103 (incomplete framing,plumbing, electrical, mechanical), room 106 (support condensate drain at bathroom) 107 ( leak at bathroom pex), 109 (exterior double studs over notched) 113 (stud at laundry room broken) partial pass for 108 kitchen wall
05/21/2026 COT - HCEL - Electrical Intermediate Partial Pass 5/21/2025 Partial pass. 101,102,103,104,105,106,107,108,109
110,111,112,113,114,117,118,119,120. Approved. All corrections were made.
05/22/2026 COT - HCEL - Electrical Intermediate Partial Pass 5/22/2026 partial pass. 1st floor corridors approved.
12/23/2025 COT - HCEL - Electrical Intermediate Partial Pass 12/23/25: TMPP CLEARANCE FOR 701 W CONGRESS ST (Temp power for construction trailer)