Permit: TC-COM-0525-01018

Parcel: 11619131A


Addresses:

701 W CONGRESS ST

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Building Above Ceiling 

Date Description Inspector Results Comments
04/01/2026 COT - HCBU - Building Above Ceiling  Partial Pass 4/1/26:Please do 4th floor framing above the lid
04/21/2026 COT - HCBU - Building Above Ceiling  Partial Pass 4/21/2026 partial pass. 1st and 2nd corridor 2nd layer drywall approved. Okay to proceed progress areas.
05/04/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/4/2026 Mock unit 420 drop lids approved. Okay to proceed progress areas.
05/12/2026 COT - HCBU - Building Above Ceiling  Re-inspection required 5/12/26: insulation must be completely removed throughout 3rd floor corridors for inspection. Fire blocking required at corridors @ drop ceiling (IBC 718.2.3, 718.2.1.4, 718.2, 718.2.1) please recall inspection once insulation is removed and fire blocking is in place so we can walk 2nd and 3rd floor. All structural nail plates must have drywall screws removed and shall have 8-10d nails on each side (R602.6.1, P2603.2.1). Reinspection required
05/27/2026 COT - HCBU - Building Above Ceiling  Partial Pass RC channels in place 3rd floor, rooms 312-320. 2nd floor rooms (220 not completed) 219-212. Approved. Okay to proceed with progress areas. 5/27/2026
06/03/2026 COT - HCBU - Building Above Ceiling  Re-inspection required MEP above ceilings 4th floor soffit areas in rooms 419(provide blocking on 3sides to registers. Add strap for dryer duct in closet, missing fire caulking at sprinkler line, add saddle straps to flex lines),418(open hole at light in closet, block registers in three sides seal off exterior fire walls),417(seal off feeder penetration,flex in closet smashed,tape off any tears in flex,add strap to 6” duct living area) stopped inspection. 6/3/2026
06/05/2026 COT - HCBU - Building Above Ceiling  Partial Pass Partial pass. RC channel 210,209,205,202,201 approved. Okay to proceed progress areas. 6/5/2026
06/08/2026 COT - HCBU - Building Above Ceiling  Not Ready 6/8/2026 not ready per previous notes. Stopped inspections
06/10/2026 COT - HCBU - Building Above Ceiling  Partial Pass 6/10/2026 partial pass. 4th floor MEP corrections were made and approved at dropped ceilings. Okay to proceed progress areas.