Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Inspections
Type:
Commercial Building
Address NEW:
3430 E VALENCIA RD
Apply Date:
02/23/2026
Applicant:
Chris Ward
Description:
Proposed construction of a 162,240 sf SHELL ONLY/Speculative Building and associated site work

Permit Reviews

Permit Number - TC-COM-0226-00261
Permit Status: Inspections
Permit Description: Proposed construction of a 162,240 sf SHELL ONLY/Speculative Building and associated site work
Start Date Submittal Complete Date Status  
02/27/2026 COMMERCIAL REVIEW - FULL v.1 03/24/2026 REQUIRES RESUBMIT Review Details
05/20/2026 COMMERCIAL REVIEW - FULL v.3 05/28/2026 REQUIRES RESUBMIT Review Details
07/14/2026 COMMERCIAL REVIEW - FULL v.5 07/29/2026 APPROVED Review Details
04/20/2026 COMMERCIAL REVIEW - FULL v.2 05/12/2026 REQUIRES RESUBMIT Review Details
06/01/2026 COMMERCIAL REVIEW - FULL v.4 06/01/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0226-00261
Permit Status: Inspections
Permit Description: Proposed construction of a 162,240 sf SHELL ONLY/Speculative Building and associated site work
Total Outstanding Activity Conditions - 7
Date Name
03/23/2026 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
03/23/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/23/2026 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
03/23/2026 SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED.
03/23/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
05/27/2026 SPECIAL INSPECTION FOR COLD FORM STEEL FRAMING IS REQUIRED.
05/27/2026 SPECIAL INSPECTION FOR WOOD FRAMING IS REQUIRED.

Conditions

Permit Number - TC-COM-0226-00261
Permit Status: Inspections
Permit Description: Proposed construction of a 162,240 sf SHELL ONLY/Speculative Building and associated site work
Date Description Comments
02/27/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
02/27/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/23/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0226-00261
Permite Description: Proposed construction of a 162,240 sf SHELL ONLY/Speculative Building and associated site work
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
08/28/2026 BULD - Electrical Clearance N/A Re-inspection required 8-28-26: contractor requested temp power. Please submit an electrical site plan to the city for review & approval. 2 layers of felt paper are required behind panel, label breakers, and install a weather resistant gfci at panel.
09/09/2026 COT - LCEL - Electrical Underground N/A Partial Pass 9-9-26: 2 separate trenches each containing 2-4" & 4-2" Schedule 40 electrical secondary conduits stemming from electrical room in a northern direction. Okay to backfill approximately 130' of trenches using shading materials.
09/09/2026 COT - LCPL - Rough Soil N/A Partial Pass 9-9-26: underground plumbing verified under test and per floor plumbing plan-P1.0. Correct number of clean outs together with tracer wire for underground plumbing outside of slab. Okay to backfill using shading materials.