Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address:
1 E BROADWAY BL
Address NEW:
1 E BROADWAY BL
Apply Date:
08/06/2012
Applicant:
N/A
Description:
MULTI-STORY MIXED USE
Contractors:
  • CAYLOR CONSTRUCTION COMPANY , RO

Permit Reviews

Permit Number - T12CM04806
Permit Status: C of o
Permit Description: MULTI-STORY MIXED USE
Start Date Submittal Complete Date Status  
01/31/2013 REVISION - - 2ND 02/26/2013 COMPLETED Review Details
02/26/2013 REVISION - - 2ND 05/17/2013 COMPLETED Review Details
08/06/2012 PLANS OK TO SUBMIT - COMM 08/06/2012 COMPLETED Review Details
08/06/2012 COMMERCIAL - NEW 08/31/2012 COMPLETED Review Details
09/10/2012 RESUBMITTAL 09/26/2012 COMPLETED Review Details
09/26/2012 RESUBMITTAL 11/01/2012 COMPLETED Review Details
11/01/2012 REVISION - - 1ST 11/01/2012 COMPLETED Review Details
11/01/2012 REVISION - - 1ST 11/26/2012 COMPLETED Review Details
11/27/2012 REVISION - - 1ST 11/27/2012 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T12CM04806
Permit Description: MULTI-STORY MIXED USE
Total Completed Inspections - 52
Date Description Inspector Results Comments
11/20/2012 ELECTRIC - UFER LHANLY Approved supplementary ground at transformer pad ok
12/05/2012 ELECTRIC - UNDERGROUND LHANLY Approved CONTINUATION OF SECONDARY INTO BASEMENT OK
12/12/2012 BUILDING - PROGRESS LHANLY Approved SHOTCRETE SHORING OK
12/28/2012 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved LINE 11/ E-H OK TO PLACE
12/28/2012 STEM WALL/RETAINING WALL LHANLY Approved LINE D / 3-4.5 BASEMENT LEVEL OK TO PLACE.
12/28/2012 STEM WALL/RETAINING WALL LHANLY Approved A.M. INSPECTION REQUEST FOR CIP WALL LINE D/ FROM 3 - 4.5 ONLY. CORRECTIONS STILL NOT MADE PER DISCUSSION WITH FOREMAN AND STEEL CONTRACTOR FROM YESTERDAY. IT IS NOT ACCEPTABLE TO FIELD BEND PARTIALLY EMBEDDED REINFORCING STEEL. PLEASE REFERENCE PLAN NOTES AND ACI 318 SECTION 7.3.2.
12/28/2012 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved CONT. LINE G / 5-8 AND SPREAD FOOTINGS LINE F/ 5 & 6

PREVIOUSLY APPROVED LINE D AND LINE 1, PLUS STAIR 1 AND ELEVATOR PIT
07/09/2013 REINFORCED MASONRY PRE-GROUT LHANLY Approved
08/14/2013 PLUMBING - PRE SLAB LHANLY Approved
08/14/2013 PLUMBING - ROUGH, SOIL LHANLY Approved
08/14/2013 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved
08/14/2013 BUILDING PRE-SLAB LHANLY Approved
09/09/2013 MECHANICAL - HYDRONIC PIPING LHANLY Approved
09/09/2013 ELECTRIC - CABLE DROP LHANLY Approved
09/09/2013 ELECTRIC - TEMPORARY SERVICE LHANLY Approved OK TO CLEAR ECO FOR OWNER METER , CEC CLEARANCE ONLY FOR OTHER SES SECTIONS.
09/09/2013 FRAMING LHANLY Approved
10/02/2013 PLUMBING - BACK WATER VALVE LHANLY Approved
10/02/2013 PLUMBING - SEWER HCS CONNECT LHANLY Approved
10/02/2013 PLUMBING - ROOF DRAINS LHANLY Approved
10/15/2013 MECHANICAL - ABOVE CEILING LHANLY Approved
10/15/2013 PLUMBING - ABOVE CEILING LHANLY Approved
10/15/2013 ELECTRIC - ABOVE CEILING LHANLY Approved
10/22/2013 PLUMBING - INTERMEDIATE LHANLY Approved
10/22/2013 ELECTRIC - INTERMEDIATE LHANLY Approved
10/22/2013 ROOF NAILING LHANLY Approved
11/08/2013 TEP CLEARANCE - AM LHANLY Approved ECO UNITE 601-612 & 701-712 (24 UNITS TOTAL)
11/19/2013 MECHANICAL - INTERMEDIATE LHANLY Approved
11/19/2013 PLUMBING - YARD WTR LINE/TEST LHANLY Approved
11/19/2013 ELECTRIC - PROGRESS LHANLY Approved
11/19/2013 BUILDING ABOVE CEILING LHANLY Approved
11/20/2013 PLUMBING - PROGRESS LHANLY Approved
11/20/2013 PLUMBING - GAS PRESS TEST FNL LHANLY Approved
11/20/2013 PLUMBING - GAS PRESSURE TEST LHANLY Approved
11/20/2013 SHEET ROCK NAILING LHANLY Approved
11/20/2013 FIREWALL/FIREBARRIER/FIRESTOP LHANLY Approved
11/20/2013 U VALUE FOR WINDOW LHANLY Approved
11/20/2013 STUCCO MESH LHANLY Approved
12/18/2013 FIRE - ALARM FINAL CSCHULTZ Approved 1. Wire fire bell
2. Wire and test elevator operations
3. Install outside horn/strobe on roof top
4. All fire/smoke dampers shall close when fire alarm actives
5. Need to test smoke for elevators
12/20/2013 MECHANICAL - FINAL LHANLY Approved LEVEL 6 OK
12/20/2013 PLUMBING - FINAL LHANLY Approved LEVEL 6 OK
12/20/2013 ELECTRIC - FINAL LHANLY Approved LEVEL 6 COMPLETE
12/20/2013 BUILDING - FINAL LHANLY Approved LEVEL 6 DWELLING UNITS OK
12/26/2013 FIRE - FINAL CSCHULTZ Approved Temporary fire final Approved for residents to move in to get final fire final the following shall be completed:
Emergency generator back power was tested and all floors passed.
1. 7th floor east stairwell failed to shut closed
2. 6th floor finish tape and mud on fire rate ceilings
3. Between 4th and 5th stair landing emergency lighting failed east
4. 4th floor east stairwell smoke gasket needed
5. 3rd floor east stairwell not closing
6. 4th floor exit signs not working on emergency power in lobby
7. Emergency phones do not work
8. Doors in stairwells failed to unlock during emergency power
9. Sprinkler bell failed when tested
10. When fire pump was switched off came in as 7th floor trash chute and fire pump??
11. In key boxes need label all keys and need key for the electrical room added
12. 3rd floor by west stairwell sprinkler head blocked by led lights 18" to 24" away from led
13. For interior exit stairway IBC & IFC 2006 & 2012 section 1020.1.5. & 1022.8 - add a directional exit sign(s) on ground level floor and an approved barrier is provided at level of exit discharge to prevent persons from unintentionally continuing into levels below.
14. Need elevator keys in key box and 3 recall and one elevator door opener
15. Per 2006 IBC section 716.3.2.1 you will need all fire/smoke dampers to close by detectors and fire alarm activation.
16. Need to install and test emergency key switch for main entrance doors
12/26/2013 FIRE SPKLR - UG, PIPING, HYDRO CSCHULTZ Approved
12/26/2013 FIRE SPKLR - UG PIPING FLUSH CSCHULTZ Approved
12/26/2013 FIRE SPKLR - FINAL CSCHULTZ Approved
01/17/2014 RIGHT OF WAY - FINAL TWOLFGAN Approved
01/17/2014 SIGN - FINAL MRUSSO Approved
01/17/2014 LANDSCAPE - FINAL MRUSSO Approved
01/17/2014 ENGINEERING - FINAL MRUSSO Approved
01/21/2014 FIRE - LANE SIGNS CSCHULTZ Approved
01/22/2014 FIRE - KITCHEN EXH HOOD FINAL CSCHULTZ Approved No hood system installed