Permit: T12CM04806

Parcel: 11712087C


Addresses:

1 E BROADWAY BL


Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Permit Number - T12CM04806

Inspection Description - BUILDING PRE-SLAB

Inspection Status - Approved

Date Description Inspector Results Comments
08/14/2013 BUILDING PRE-SLAB Approved
05/20/2013 BUILDING PRE-SLAB Partial Approval EAST 1/2 6TH FLOOR OK TO PLACE
05/15/2013 BUILDING PRE-SLAB Denied SLAB NOT READY. CABLES TOO CLOSE TO 1 SLEEVE, 2 COLUMNS AND PART OF CIP WALLS INTRUDING INTO BOTTOM OF DECK, HEADS OVERLAPPING AT SE CORNER, HAIRPINS IMPROPERLY PLACED AT SWEEPS, MILD STEEL BURNING DECK OR IMPROPERLY PLACED BEHIND PT HEADS.
05/06/2013 BUILDING PRE-SLAB Partial Approval WEST 1/2 LEVEL 6 OK TO PLACE
04/18/2013 BUILDING PRE-SLAB Partial Approval ALL SLAB POURS WERE INSPECTED AND APPROVED UP TO LEVEL 5 WEST POUR (COMPLETED 4/17)
03/18/2013 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :* LEVEL 3 WEST
03/12/2013 BUILDING PRE-SLAB Partial Approval RAMP 2 - 3 OK
03/06/2013 BUILDING PRE-SLAB Partial Approval LEVEL 2 AREAS 1 & 2 INSPECTIONS COMPLETED AND POURS DONE.

NEED FIX FOR DAMAGED TENDON AT JOINT (STRESSING BREAK)
02/26/2013 BUILDING PRE-SLAB Partial Approval SLABS AND RAMPS THROUGH LEVEL 1 OK
02/26/2013 BUILDING PRE-SLAB Partial Approval RAMP FROM 1 - 2 OK
02/26/2013 BUILDING PRE-SLAB Partial Approval LEVEL 2 ELEVATED SLAB TENDON COUNT, AND COLUMN CAPS OK. NEED TO CORRECT SLOPES ON TENDONS AND ADD XTRA REBAR NOTED ON PT DRAWINGS AT RAMP.