Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T12CM04806

Parcel: 11712087C


Addresses:

1 E BROADWAY BL


Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Permit Number - T12CM04806

Inspection Description - BUILDING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
11/20/2013 BUILDING - PROGRESS Approved
10/22/2013 BUILDING - PROGRESS Partial Approval SHAFTS HAVE NOT BEEN PROPERLY BUILT ON LEVELS 6 & 7. REBUILD OR INSTALL A FIRE STOP SYSTEM AT EACH FLOOR CEILING ASSEMBLY.
10/02/2013 BUILDING - PROGRESS Partial Approval
09/19/2013 BUILDING - PROGRESS Partial Approval Intermediates for all rooms on level 6 except for 608 & 610 are complete
09/16/2013 BUILDING - PROGRESS Partial Approval 6th floor rooms on south ok to cover. need to reinspect shaft wall next to elevator.
09/13/2013 BUILDING - PROGRESS Partial Approval SHEATHING AT CANOPIES AND NORTH SIDE OK
06/05/2013 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
06/05/2013 BUILDING - PROGRESS Not ready for Inspection 1. 2ND 8' LIFT CL "D"BETWEEN CL 1 & 2 OK TO GROUT. ALSO 2ND 8' LIFT CL 1 BETWEEN CL "E" AND "F"
2. 3RD LIFT CL "A" BETWEEN CL 7 & 9 OK TO GROUT
05/20/2013 BUILDING - PROGRESS Partial Approval additional slab support for level 2 line D ok. (repair for improper correction of column cap)
03/22/2013 BUILDING - PROGRESS Partial Approval ELEVATOR 3 CORE
03/21/2013 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
03/20/2013 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*COLUMN GL D-1,3, E-1,3,4, F-1.2,3,4, G-1,2,3, 3RD LEVEL
12/12/2012 BUILDING - PROGRESS Partial Approval SHOTCRETE SHORING OK
12/05/2012 BUILDING - PROGRESS Partial Approval CONTINUED PROGRESS ON SHORING (SOIL-NAILS) OK DOWN TO BASEMENT GRADE.