Permit: T05CM01569
Permit Details
Apply Date:
04/08/2005
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:RETAIL
Architects:
- CATALANO, VINCENT VICTOR
Contractors:
- RED LINE CONSTRUCTION COMPANY INC
Permit Reviews
Permit Number - T05CM01569
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/08/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 03/08/2006 | COMPLETED |
04/08/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 04/08/2005 | COMPLETED |
04/08/2005 | 3RD PARTY REVIEW-COMMERCIAL TI | 05/10/2005 | COMPLETED |
05/11/2005 | POST 3RD PARTY REVIEW | 05/17/2005 | COMPLETED |
05/19/2005 | RESUBMITTAL | 06/02/2005 | COMPLETED |
06/02/2005 | RESUBMITTAL | 06/06/2005 | COMPLETED |
09/23/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 09/26/2005 | COMPLETED |
09/26/2005 | POST 3RD PARTY REVIEW | 10/04/2005 | COMPLETED |
12/28/2005 | REVISION | 01/12/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM01569
Permit Status: C of o
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/08/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM01569
Permit Description: TI:RETAIL
Total Completed Inspections - 30
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/17/2005 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | IVRS - Inspection :* |
06/20/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | 1) SANITARY DRAINAGE SYSTEM UNDERGROUND ONLY WATER TEST TO 10' ABOVE FINISH FLOOR OK PENDING CITY APPROVAL OF RED LINE DRAWING ON SITE. COVER AT OWN RISK. WILL REQUIRE INSTALLATION OF FIXTURE DRAINAGE FITTINGS AND VENT THRU ROOF TEST AT FUTURE DATE 2) CALL IN FOR PIPE WRAP INSPECTION PRIOR TO CONCRETE POUR BACK 3) GREASE WASTE REQUIRES DIRECTIONAL FITTING FOR CLEANOUT ON DOWN STREAM SIDE, CORRECT INSTALLATION ON GREASE TRAP TO GREASE WASTE PIPING. I.E. PIPING AND TRAP SHOULD BE SAME PIPE SIZE. DO NOT COVER GREASE WASTE SYSTEM |
06/20/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | CONST POWER |
08/15/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* 1) OK STUD FRAME WALLS |
08/18/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* 1) DWV WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) GAS PRESSURE TEST ON ROOF ONLY IS OK 4) ALL CORRECTIONS HAVE BEEN MADE |
08/18/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* 1) OK TO ROCK 2) YOU NEED BACKING FOR GRAB BARS IN RESTROOMS-REFERENCE PP A4 FOR LOCATIONS 3) NEED TO FURR OUT SOUTH WALL IN RESTROOMS SO THAT CENTER OF W.C. IS 16" TO 18" FROM SIDE WALL 4) PROVIDE STAMPED LETTER FROM ARCHITECT TO REVISE DETAIL 1/A4 FROM 25 GA METAL STUDS AT 24" TO 2 X 4 WOOD STUDS AT 16" |
10/03/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* YOU WILL HAVE TO PROVIDE HEATED MAKE UP AIR TO THE KITCHEN. HANGING A HEATER IN THE KITCHEN DOES NOT SATISFY THE PROVISIONS SET FORTH IN SECITON 508.1.1 2000 INC |
10/26/2005 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* 1) CHECKED FIRE WRAP |
12/14/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* ANSWER QUESTIONS |
02/03/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) AS PER OWNER, DUCT HEATER WILL NOT BE INSTALLED 2) MAKE UP AIR VENTS HAVE BEEN REPOSITIONED SO AS NOT TO CAUSE DISCOMFORT 3) OK FOR FINAL C OF O |
02/03/2006 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | PER MECH FINAL |
02/03/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | PER MECH FINAL |
02/03/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
02/03/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
02/03/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
02/23/2006 | OUTDOOR LIGHTING FINAL | RSUBA | Approved | PER EL FINAL |
02/23/2006 | ELECTRIC - OUTDOOR LIGHTING | RSUBA | Approved | PER EL FINAL |
02/23/2006 | ELECTRIC - RECONNECT | RSUBA | Approved | PER EL FINAL |
02/23/2006 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* |
03/07/2006 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
03/07/2006 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
03/13/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
03/17/2006 | FIRE - FINAL | LLAKEY | Approved | |
03/17/2006 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
03/22/2006 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | PER PL FINAL |
03/22/2006 | BUILDING ABOVE CEILING | JBURGE | Approved | PER BU FINAL |
03/22/2006 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
06/06/2006 | ENGINEERING - FINAL | JBRUCKME | Approved | TEMPORARY C OF O CONTINUED... 1. PATCH ASPHALT AT LANDSCAPE AREA AND ACROSS SOUTH DRIVEWAY. ASPHALT PATCH MUST MATCH EXISTING GRADE AND BE HARD. 2. PROVIDE HANDRAIL AT HANDICAP ACCESS RAMP AT REAR OF BUILDING AND ELIMINATE DEPRESSION AT TOP OF RAMP. |
05/14/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
05/21/2007 | SIGN - FINAL | JYBARRA | Approved |